Summary of Contents for Garden Air FAI-150-0151

  • Page 1 Dehumidifier User Manual...
  • Page 2 This manual is an integral part of the product and must be supplied to the installer and the end user. The advice included in this manual must be carefully read as they supply important indications about safety and maintenance. Keep this manual in order to consult it if necessary.
  • Page 3 installations. A failing installation can cause damages to persons, pets or items. Manufacturer shall not be held responsible for any failure to comply with safety and maintenance instructions set forth in the manual . When unpacking the unit, check its state. Before connecting the unit, make sure that the advice supplied by this manual are in accordance with the installation and its conditions of use.
  • Page 4 IMPORTANT * CAUTION * IMPORTANT Before any servicing, maintenance and repair, switch off the main supply. In event of failure or abnormal operation, switch off the unit before any repair. Any repair shall be performed by authorized service personnel with genuine spare parts.
  • Page 5: Table Of Contents

    Content I.  Please read immediately ................1  II.  Delivery Conditions ................. 2  III.  NF C15.100 Pool regulation ..............2  IV.  Voltage ..................... 3  V.  Application ....................3  VI.  Features ....................3  VII.  Description & Technical Parameters ............4  VIII.  Overall Dimension ................... 5  IX. ...
  • Page 6: Please Read Immediately

    Please read immediately Attention! This machine is an ordinary Dehumidifier and can never be used for regulating other combustible gas and stale air. The main power switch should be installed out of the reach of children to avoid dangers caused by their playing with the switch. If it is necessary to remove the machine shell during repair and maintenance, please make sure that power has been cut off.
  • Page 7: Delivery Conditions

    II. Delivery Conditions Every product can be harmed during transportation, even if well packed and issued, so the transporter should know about these risks that can occur during transport. A delivery list should be made, in which any damage made during transportation should be registered.
  • Page 8: Voltage

    IV. Voltage Before any operation made, the voltage should be checked: it must be the same that the one indicated on the product and the supply chain. V. Application Economically and efficiently dehumidification, providing you a cozy environment. Users can decide an appropriate model by referring to the technical parameters and under the guidance of professional personnel.
  • Page 9: Description & Technical Parameters

    VII. Description & Technical Parameters Mode Ref. FAI-150-0151 FAI-150-0012 FAI-150-0013 Operating Temperature (℃) 10~38 10~38 10~38 Capacity in (l/h) (Air 30℃,Humid 70% ) Heat Recovered (kW) Rated Power (kW) Rated Current (A) 4.58 7.83 9.15 Max Input Power (kW) 2.45 Max Input Current (A) 9.15...
  • Page 10: Overall Dimension

    1. The rated current of electric heating is 8.7A for FAI-150-0151, 13A for FAI-150-0012 & FAI-150-0013. 2. Dehumidifying capacity refers to the dehumidifying volume when keeping the relative humidity at 30℃/70% . Devices of this series can operate normally at the temperature of 10℃~38℃.
  • Page 11: Installation Guide

    Size(mm) Name Model FAI-150-0151 FAI-150-0012 1186 FAI-150-0013 1186 Note: Above dimension is only for reference of professional workers during installation and arrangement. Due to the continuous improvements, the products will have phase adjustments without additional notices. IX. Installation Guide 1. Position: The distance of dehumidifier must be over 2 meters from the swimming pool.
  • Page 12 A: signal line; B: power line; C: water outlet Note: The figure above is an example and the machine installation and arrangement is only for reference. 2. Electrical wiring diagram Breaker/fuse (Customer prepare) Power Cord Earthing Power Supply 220~240V 50Hz Note: The Dehumidifier must have a good grounding.
  • Page 13 3. Selection of protective device and cable specification Type FAI-150-0151 FAI-150-0012 FAI-150-0013 Rated current Leakage circuit Rated residual breaker Operating current mA Fuse Power cable (mm 3×2.5 3×4 3×4 Signal line (mm 3×0.5 3×0.5 3×0.5 Note: The data above is suitable for power lines shorter than 10 meters. For those longer than 10 meters, the wire diameters must be increased.
  • Page 14: Lcd Controller Operation

    Electrical wiring installation The supply voltage should be in line with the rated voltage of this product. The Dehumidifier must have a good grounding. Wiring must be conducted by professional technicians in accordance with the standards of circuit diagram. According to related technical standards for electrical equipment set by local region or country, the electric leakage protection device must be well set (residual operating current should be less than 30 mA).
  • Page 15 1. Display: a. The screen will display actual relative humidity (%) and ambient temperature (℃) when the machine is off. b. The screen will display following message when the machine is on. 1. Mode; 2. Actual relative humidity(%) and ambient temperature(℃); 3.Fan speed and timer if set.
  • Page 16 Timer Setting: ① Set timer When the device is on, the off time can only be set as 1~12H. When the machine is off, the on time can only be set as 1~12H. Press button “ ”: Start the timer setting and change the timer time through button “▲”and“▼”.
  • Page 17: Test Running

    XI. Test running 1. Before usage A、Check whether the whole machine is place on the ground vertically and be connected with drain hose. B、Check whether the electrical wiring has been connected in accordance with the electrical wiring diagram and whether the earth wire has been linked reliably.
  • Page 18: Repair And Maintenance

    F、Please do not stand on or lean against the machine. G、Please do not use it to preserve the artworks or academic materials or for other special purposes, otherwise the quality of restored objects could not be guaranteed. H、This machine is only for indoor use. Please do not use it under the conditions with direct sunlight or wind and rain.
  • Page 19: General Troubleshooting

    XIV. General Troubleshooting fault Cause Handling method Waiting power Power cut restoration Power switch not on Switch on the power Check the problem and Fuse burnt out Not operating replace the fuse Check the problem and Leakage circuit breaker switch on the leakage circuit being off breaker Wait to end the defrost cycle...
  • Page 20: Recycling

    performed a visual inspection of the state of obstruction batteries (evaporator / condenser and hot water) disassembling the lid (off). Depending on the state, effective cleaning with the help of a brush on silk and a vacuum cleaner XVI. Recycling In accordance with the European Directive 2002/96/EC, and in order to reach a number of environmental protection objectives, the following rules must be obeyed.
  • Page 21 Coil temperature 1. Check if terminal “SEN5” on the PCB got Loosen sensor failure 2.Replace corresponding sensor Humidity sensor 1. Check if terminal “H-SEN” on the PCB got loosen failure 2.Replace corresponding sensor Outlet temperature 1. Check if terminal “SEN2” on the PCB got Loosen sensor failure 2.Replace corresponding sensor Return gas...
  • Page 22: Appendix 1:Installation Of Heating Element(Optional)

    Appendix 1:Installation of Heating Element(Optional) Warning : The heating element of dehumidifier must be installed by qualified electrician. A. Component List : 1) Heating Element 1 pc 2) Screws 4 pcs E (yellow) N ( blue) L(red) Signal wire B. Steps 1、...
  • Page 23 3、 Wiring of Signal Cable & Power Cable A、 Wiring Signal Cable: Open the electrical compartment Find Signal Wire Remove the yellow wire Plug in Signal wire B、 Wiring Power Cable : Please refer to the diagram below for connecting power cable. ( “L” port can be found on PCB )
  • Page 24 4、Re assemble the front panel of the dehumidifier, fasten the panel by using screws on both sides Upon completion of installation, please reset inner parameter “C1” to 1 (Default value :0)...
  • Page 25 Appendix 2: Inner Parameter Setting Enter inner parameter setting interface by pressing “SET” for 3 seconds Fasten it with 4 scr Warning: Non-professional is not recommended to avoid error by incorrect operation. : Inner parameter’s checking & setting Press button “SET” for three seconds and enter the menu of parameter checking &...
  • Page 26 The parameter table is as follows: Parameter code Parameter specification Default value meaning Heating or not 0 no/1 yes Measured Coil temperature -20℃~99℃ value Humidity -5% ~ 5% compensation Defrosting cycle 15Min~90Min 20Min Defrosting starting -10℃~10℃ -1℃ temperature Defrosting closing 0℃~15℃...
  • Page 27: Appendix 3: Explosive Diagram & Pcb Layout

    Appendix 3: Explosive Diagram & PCB layout Explosive Diagram FAI-150-0151 FAI-150-0012 FAI-150-0013 Inlet Grid 003060010201-R 003060010201-R 003060010201-R Filter and Filter Bracket 002060030998-R 003991200000-R 003991200000-R Front Panel 003060030101 003060010101 003060010101 Vibration absorber 004990050000 004990050000 004990050000 Outlet Grid 003060010201-R 003060010201-R 003060010201-R Front Seal Panel...
  • Page 29 PCB layout OUT4: Fan(High Speed) CN1:Transformer Input Fuse AC-N OUT5:Fan(Low Speed) CN2:Transformer Output Electrical heater power LED terminal P1:High Pressure Switch Power output (L) P2:Low Pressure Switch Compressor output P4:Electrical heater CN19:EEV SEN6: SEN5 SEN1: SEN2: H-SEN: Version: H64B-140715...