Download Print this page

Cartridge Installation - Omegalink OL-BLADE-AL(DL)-CH7-EN Install Manual

Blade series alarms & remote start

Advertisement

INSTALL GUIDE
Page 20 of 23
1
MODULE PROGRAMMING PROCEDURE - WITH KLON - 1 OF 2
1
2
3
x1
4
5
Æ
6
x2
U.S. Patent No. 8,856,780
OL-BLADE-AL(DL)-CH7-EN

CARTRIDGE INSTALLATION

Slide cartridge into unit. Notice
button under LED.
Close driver door.
Re-open driver door to wake up
data bus.
Press UNLOCK on keyfob 1.
Wait, LED will fl ash BLUE once
[1x].
Remove valet key from keyfob 1.
Remove batteries from keyfob 1.
Push start button twice [2x] with
keyfob 1 to ON position.
(No battery)
2
7
Æ
8
x1
9
x2
10
Æ
11
x1
12
13
IMPORTANT: READ NEXT PAGE !
È
All in one
Chrysler/DoDge/Jeep/rAM
20160803
Doc. No.: ##29198##
Ready for Module Programming
Procedure.
Wait, LED will turn solid RED.
Push start button once [1x] to
OFF position.
Push start button twice [2x] with
keyfob 1 to ON position.
(No battery)
Wait, if LED fl ashes BLUE
rapidly, proceed to step 11.
If LED turns solid RED, repeat
steps 8 to 10.
Push start button once [1x] to
OFF position.
Disconnect all connectors from
remote starter except the power
connector.
Disconnect the power
connector.