Hide thumbs Also See for BAFFIN TRIO:

Advertisement

Quick Links

MANUAL FOR
BAFFIN TRIO
sizes: 1,2 control: automatic
Edition 1 - 18.07.2017

Advertisement

Table of Contents
loading

Summary of Contents for LIW BAFFIN TRIO

  • Page 1 MANUAL FOR BAFFIN TRIO sizes: 1,2 control: automatic Edition 1 - 18.07.2017...
  • Page 2 NOTE! THE MANUFACTURER IS SOLELY RESPONSIBLE FOR THE EQUIPMENT PURCHASED FROM A DIRECT REPRESENTATIVE OF LIW CARE TECHNOLOGY, OR IN SPECIALIZED MEDICAL SHOP REPRESENTING LIW CARE TECHNOLOGY IN POLAND. NOTE! USE ONLY INDOOR WITH NO THRESHOLDS. NOTE! WHEN USING THE PRODUCT, IT SERVICE, MECHANISMS SUBMITTING AND REGULATING, IT MAY OCCUR DANGER OF ENTRAPMENT AND/OR COMPRESSION OF USER’S/ACCOMPANYING PERSON BODY IN HOLES/SLOTS BETWEEN THE ELEMENTS.
  • Page 3: Table Of Contents

    Introduction ............................4 Warnings & Safety Information ......................4 Technical Information ........................5 Technical Specification ........................6 Intended Use ............................ 7 Setting and Adjustment ........................7 5.1.1 Width and Depth Adjustment of the Multifunctional device ............7 5.1.2 Width Adjustment ..........................7 5.1.3 Removing Pelvic Supports ........................
  • Page 4: Introduction

    Complimentary training is available from the Distributors. In order to benefit from all the features of the Baffin TRIO, it is important to ensure that the product is properly set and adjusted to the User's particular needs prior to use.
  • Page 5: Technical Information

    8. Knee Support 20. Respirator Shelf 9. Footrest 21. Spine Interlock 10. Foot Platform 11. Standing Base 12. Seat Fig. 1: Frame Work Of Multifunctional device The equipment of Baffin TRIO Multifunctional device is available depending on the Continent, Country.
  • Page 6: Technical Specification

    3.1 Technical Specification There are two sizes of an individual standing seat available. Detailed size parameters are presented in the table below: Size I (cm) Size II (cm) Seat height (SH) Back height (BH) Backrest Angle (BA) ÷ 115 ÷ 115 Verticalization Range (VR) ÷...
  • Page 7: Intended Use

    It is primarily for indoor use only. It is not suitable for manoeuvring kerbs. It is not intended for transport, therefore the user should not be transported in the Baffin TRIO in a vehicle. Intended Users are those with faulty postures and muscle dysfunction.
  • Page 8: Removing Pelvic Supports

    Fig. 4: Thigh Supports Width Adjustment The knobs are situated on the left and right sides of the device. They operate independently. It allows symmetrical and asymmetrical position of the user's body. To adjust the spacing between the thigh supports, use the two knobs which are situated under the thigh supports (Fig.
  • Page 9: Removing The Plastic Covers

    5.1.4 Removing the Plastic Covers Before adjusting the depth of the seat, remove the plastic cover on both sides of the machine. The covers are fixed with the use of 4 screws (2 on each side), placed on the top and bottom covers (Fig. 6). Fig.
  • Page 10: Depth Adjustment

    5.2 Depth Adjustment To adjust the depth of the seat, use the blocking screws marked with the red arrows (Fig. 9). It is possible to change the depth of the device after the screws have been completely undone on both sides of the device. Push in or pull out the back part of the seat into the right depth.
  • Page 11: Lateral Supports Adjustment

    5.4 Lateral Supports Adjustment 5.4.1 Lateral Supports Width Adjustment In order to adjust the width and height of the lateral supports, unscrew the knob marked with a red arrow in Figure 11. After adjusting the width and height of the lateral supports, tighten the knob. Fig.
  • Page 12: Armrests Adjustment

    5.5 Armrests Adjustment The Armrest system makes it possible to smoothly adjust the angle, the height and the spacing of armrests. In order to change the angle of armrests, loosen the blocking knobs (Fig. 13), and then, after setting the right angle, block the mechanism of armrests by tightening.
  • Page 13: Footrest Adjustment

    5.6 Footrest Adjustment The footrest is used to support the feet while sitting, lying down and during tilting. The footrest is adjustable by: - height, - angular positioning of the foot platforms. 5.6.1 Adjusting the Height of the Footrest Inappropriately tightened knobs and screws can cause the footrest to move in the upright position and can lead to injury or damage to the device.
  • Page 14: Fastening The Feet Onto The Foot Platform

    Fastening the feet onto the foot platform For safe handling of the BAFFIN TRIO Multifunctional device, it is necessary to fasten the user’s feet onto the foot platform. Fastening the feet is carried out with the help of four straps. Unfasten the strap buckles, place feet on the platform, adjust the straps so that they lie tightly close against the feet.
  • Page 15: Regulating And Adjusting The Knee Supports

    To close the knee support, start by putting the shoulder of the knee support in the lock and then moving the knee support to the user's knee. After setting the right distance from the user's knee (i.e. the minimum space between the user's knee and the knee support which does not cause discomfort), block the knee support with the knob.
  • Page 16: Fitting And Adjustment Of The Vest And Hip Belts

    It is essential that a Clinician specifies the shape of the back support. 5.9 Fitting and adjustment of the vest and hip belts The vest and hip belts are used to secure the correct position of the user in the seat. The vest and the hip belts are attached to the device with the use of belts.
  • Page 17: Changing Position

    Changing position 6.1 Changing position/verticalization The Baffin Trio is equipped with a remote control to easily change the seat’s position. The user can be put into the standing position from a sitting or a lying position. The user cannot be put into upright position until all the adjustment procedures are completed. SEE Section 5 above.
  • Page 18: Changing Position From Sitting Into Laying

    6.3 Changing Position from Sitting into Laying Push the button on the remote control which is marked with the blue arrow (Fig. 25) – the back support will start to recline/ bend down and the footrests will start moving up. Keep pushing the button on the remote control until the device is in laying position.
  • Page 19: Table

    7.2 Table Before fitting, adjust the spacing between the handles of the table to the spacing of the armrests. Inappropriate adjustment might cause the table to be unstable, damage the device or risk an injury to the user. 7.2.1 Adjusting the width of table handles In order to adjust the width of the table brackets to the spacing of the armrest, loosen the screws on the table holders (shown in Fig.
  • Page 20: Built-In-Spine System Lock

    Charging mode (when system is plugged in to the network 100 – 240V): - the diode is orange, constant, short light impulses with the 1s frequency – charging - the diode is green, monotonous light – the charging is finished, and the battery is full. Low battery status is indicating by repetetive, short sound signals –...
  • Page 21: Handling The Device

    8 Handling the device Moving BAFFIN TRIO require two people. The device base should be grabbed with both hands and lifted evenly, then moved to the destination point. Fig 29 Handling the device While moving and transporting the device, plug off the remote control.
  • Page 22: Disposal Of The Product

    The economic lifetime of the product is five years. The manufacturer provides post – warranty service. Contact details: LIW Care Technology Sp. z o.o., ul. Golfowa 7, 94-406 Łódź , Poland. biuro@liwcare.pl Current contact details are available on: www.liwcare.pl Warranty terms are specified in the warranty card, which is an integral part of this statement.
  • Page 23: Symbols Meaning

    14 Compliance with the safety requirements for medical devices Baffin TRIO meets the essential requirements of the MDD 93/42 EEC for medical devices. Baffin TRIO, in accordance with Annex IX of the MDD 93/42 EEC is non-invasive non-active I class medical device according to rule 12.
  • Page 24: Warranty Card

    12. Warranty Repair or replacement will be made as far as possible within 30 days from the proper delivery of the product by the warranty user to LIW Care Technology Sp.

Table of Contents