General Information If any breakdown occurs due to the operation of the described product or users’ improper handling in accordance with the instructions of the document, S&T shall be liable for the General Conditions based on the delivery of the described product and the content of the document. This product is not designed for the use of life support appliances, devices or systems and thence a malfunction of the product might reasonably be expected to make personal injury.
Among the best features of the CAREU UCAN 3G Vehicle Tracker, in particular, they transmit data in ASCII mode (Intellitrac X Series compatible mode) or binary mode.
1.4 Hardware Architecture As hardware is concerned, the CAREU UCAN 3G is comprised of a micro- controller, regulator, GPS receiver, GSM/GPRS modem, G-Force sensor, flash memory data storage.
CAREU UCAN 3G - User Guide Chapter 2 Taking a Tour of CAREU UCAN 3G Dimensions Dimensions (L x W x H): 48mm x 66mm x 25mm 25mm 48mm 66mm PIN Assignment 1. Pin Definition of OBD II Connect Pin#...
Page 8
CAREU UCAN 3G - User Guide 2. USB Port 3. SIM Card Slot Chapter 2...
CAREU UCAN 3G - User Guide Chapter 3 Getting Started with CAREU UCAN 3G To install the the CAREU UCAN 3G device, follow the instructions below for basic operations. Hardware Installation 1. Installation Mode 2. Mini USB Cable Connect 3. SIM Card Installation...
The CAREU UCAN 3G communicates with your host computer by the USB interface. In some newer editions of Windows XP, the CAREU UCAN 3G device can be installed as a "virtual COM port" device whereby the CAREU UCAN 3G would automatically access Windows XP's inbox USB drivers.
Page 11
CAREU UCAN 3G - User Guide 1. Automatic Installation If the wizard prompts to help you install the software for "STMicroelectronics Virtual COM Port". Select Install the software automatically (Recommended). Press the Next button to proceed. The wizard proceeds to install the driver.
Page 12
CAREU UCAN 3G - User Guide The installation completes. In [Device Manager], the CAREU UCAN 3G device is included under Ports (COM & LPT) as "STMicroelectronics Virtual COM Port". COM port number is displayed as well. Chapter 3...
Page 13
(Advanced). Press the the Next button to proceed. Select Search for the best driver in these locations. Check Include this location in the search. Press the Browse button to assign where your the CAREU UCAN 3G device driver locates on your local disk.
Page 14
CAREU UCAN 3G - User Guide Press the Next button to proceed. The wizard proceeds to install the driver. Chapter 3...
Page 15
CAREU UCAN 3G - User Guide The installation completes. In [Device Manager], the CAREU UCAN 3G device is included under Ports (COM & LPT) as"S&T Tracker". COM port number is displayed as well. Chapter 3...
CAREU UCAN 3G - User Guide 3.3 Device Configuration 1. In Windows XP desktop, click Start | All Programs | Accessories | Communications | HyperTerminal. 2. If you are prompted to input the information of your location, complete them to proceed.
Page 17
CAREU UCAN 3G - User Guide 6. In the connection that you have just set up, click File | Properties. Select the [Connect To] tab. From the [Connect using] drop down list, select the correct com port by checking it up at Windows XP's [Device Manager] as previously mentioned on page and page 12.
Page 18
CAREU UCAN 3G - User Guide 7. In the File menu, click Properties. Click the [Settings] tab. Press the ASCII Setup button. 8. In the [ASCII Sending] group box. Select both Send line ends with line feeds and Echo typed characters locally. Press the OK button.
Page 19
CAREU UCAN 3G - User Guide 9. Connect your the CAREU UCAN 3G device to power as mentioned in on page The device startup message will be displayed. 10. In [HyperTerminal] window, type in the command "AT$VERSION?" and press the Enter key.
Password=password) OK AT$HOSTS=1,0,60.148.19.10,6000 (Server IP address = 60.148.19.10 and Port number =6000) AT$RETRY=5,10 (Message retry settings) AT$IPTYPE=1 (Using TCP/IP mode) AT$GPRSEN=1 (GPRS enable) AT$HB=60,1 (Heartbeat setting) Please refer to the CAREU UCAN 3G Protocol Document for more command details. Chapter 3...
CAREU UCAN 3G - User Guide GPS Tracking Configurations After the device communication settings are done, the remote GPS tracking is ready to function. The setting of GPS tracking can be done by using AT$PDSR command. For example, AT$PDSR=1,30,0,0,2,0,0,1,0 (Tracking through GPRS by time interval 30 seconds) For simple testing GPRS, run the TCP Server U-Series software which is provided by S&T.
The main page of the Intelli FleetWeb appears as below: 3.6 Firmware Upgrade The firmware of the CAREU UCAN 3G can only be updated through USB interface. With the firmware loader tool provided by S&T, firmware update can be done for the device. Such firmware loader runs on Windows-based systems. To upgrade the firmware, follow the procedure below 1.
CAREU UCAN 3G - User Guide Chapter 4 Technical Specification Characteristics Dimensions (L x W x H) 48mm x 66mm x 25mm Weight 55g Radio Performance Frequency U260 for NAR Ver. 850/1900MHz U270 for EUR Ver. 900/1800/2100MHz GSM Functionality / GPRS...
Page 24
CAREU UCAN 3G - User Guide Electrics Power Source DC 8V to 30V 150mA @ 12V (operating mode) Power Consumption 20mA @ 12V ( sleep mode) Environment –20 °C to +60 °C (Operating Temperature) Temperature –20 °C to +70 °C (Storage Temperature Note: The specification herein is subject to change without prior notice.
Page 25
CAREU UCAN 3G - User Guide Systems & Technology Corp. (S&T), founded in 1987, is a market leader in Automatic Vehicle Locating (AVL) solutions, Geographical Information Systems (GIS) and navigation. It has formed a professional development team to innovate the most advanced and comprehensive GPS tracking products for the customers and has built a global service network to provide non-stop services and support.
CAREU UCAN 3G - User Guide Chapter 5. Regulation Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.