Advertisement

CE818
User Manual
14.07-M1.5.1-H2.0-F1.41-S1.41-ENG
Made in Italy
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CE818 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Duevi CE818

  • Page 1 CE818 User Manual 14.07-M1.5.1-H2.0-F1.41-S1.41-ENG Made in Italy...
  • Page 2: Working Mode

    FEATURES OF YOUR SECURITY SYSTEM The core of your security system is the CE818 control panel, an intelligent microprocessor device that oversees the safety of persons and your home. The control panel manage up to 16 zones protect by sensors and contacts, and receives commands from LCD keyboards (Advanced mode) and electronic key readers.
  • Page 3: System Devices

    SYSTEM DEVICES CE818 DVT-LCD / DVT-OLED Electronic Control Panel LCD/OLED wired keyboard LET-485 Wired electronic keys reader Transponder electronic key ASIG / ASC / ABASC DIRF, DIRRPV, DDT-S Wired magnetic contacts Single and double technology indoor sensors E-Wall, DIRFE, barriers, MOSKITO-F...
  • Page 4 GLOSSARY Alert Function for generate a “din-don” tone from keyboards and key readers AT SYSTEM DISARMED when selected zones are violated Power Fail If the 230 V power line fall down for a long time (programmable timing), the control panel will advice and activate a dedicated output (automatic restore when power line backs up).
  • Page 5 User Menu (only in ADVANCED mode) Special menu with control panel options, only for Master users. In this menu it is possible, for example, to set date and time, manage other users, bypass zones, etc. Monitor (zone) A zone sets as MONITOR, when violated, cause only the buzzer sound on keyboards and key readers (not sirens) for 30 seconds.
  • Page 6 ADVANCED mode: it is possible to customize the events that activate each outputs (for a complete list ask to your installer). Guest User Guest users can arm and disarm the system only if enabled by a Master user. Master User Master users have high privileges on the system (except for installation and system configuration changes).
  • Page 7 KEYBOARD THE KEYBOARD CAN BE USED ONLY WITH CONTROL PANEL IN ADVANCED MODE Follows the description of buttons and functions of the keyboard: Backlit display Arming buttons / Directional Sysem status buttons Alphanumeric buttons Button “*”/ Button “#”/ CANCEL button OK button ALERT status DISARM...
  • Page 8 KEYBOARD USERS (ONLY ADVANCED MODE) The control panel manage up to 16 users  Each user can be set as:  o MASTER Master user can arm and disarm the control panel without limitations. It has access to User menu to change other users, bypass zones, change date and time and perform a system test.
  • Page 9 ELECTRONIC KEYS AND KEY READER The electronic keys are read by key readers. With the keys it is only possible to arm and disarm the system. Key reader Electronic Multicolour BASE mode  Each key stored is an user. The control panel can store up to 12 electronic keys. All the keys have the same privileges, can arm in Total, Partial and Disarm the system ADVANCED mode ...
  • Page 10: Base Mode

    BASE MODE...
  • Page 11 BASE mode 8 wired zones Max 12 electronic keys to arm the system Small system (max 8 wired zones) but with all essential functions Max 4 key readers Two arming modes: Total and Partial Alarm system upgradeable without change the control panel Communication via GSM (optional) Zones 8 on-board zones (not expandeable)
  • Page 12: Arming / Disarming

    ARMING / DISARMING TOTAL ARMING To arm the system in TOTAL mode, pass once a CHT key over a key reader. A confirming “beep” is emitted and the RED LED lights solid on key reader. A “beep” series for about 30 seconds (exit time) are emitted, then the system is armed. TOTAL arming All (zone 1 ÷...
  • Page 13 OPENED DOORS (ZONES) If the system is armed with one or more opened zones, a quick “beep” serie is emitted. After 30 seconds of this “opened zones” signalling in addiction to the 30 seconds of “exit time”, the control panel will arm normally but the opened zones will be temporary bypassed. If these bypassed zones are then closed at system armed, they will be activated: at this point they will generate alarm if violated.
  • Page 14 KEY READERS FEEDBACK When control panel is on and disarmed the LED on key reader is normally OFF. The LED lights on to signals events: BLINKING Alarm memory, number of last violated zone (at Disarmed / Off TOTAL armed disarming, for 60 seconds) Green Disarmed / Off PARTIAL armed...
  • Page 15: Advanced Mode

    ADVANCED MODE...
  • Page 16 8 onboard wired zones + 8 wired zones on expansion board + 1 zone on each ADVANCED mode DVT-LCD/OLED keyboard Max 16 electronic keys Max 16 keyboard users Max 4 LCD/OLED keyboards Max 4 key readers System with advanced functions Medium/large alarm system (max 16 wired zones) Three arming types (customizable): Total, Partial 1 and Partial 2 Auto-arming and Patrol...
  • Page 17 ARM / DISARM By factory setting, the User 1 code is enabled as MASTER type and code “100000” TOTAL ARMING To arm the system in TOTAL: With User Code With Electronic Key 1. Press the “F1” button 1. Pass once a CHT key over a key reader 2.
  • Page 18 PARTIAL 1 ARMING By factory setting, the user 1 code is enabled as MASTER type and code “100000” To arm the system in PARTIAL 1: With User Code With Electronic Key 1. Press the “F2” button 1. Pass twice a CHT key over a key reader 2.
  • Page 19 PARTIAL 2 ARMING By factory setting, the user 1 code is enabled as MASTER type and code “100000” To arm the system in PARTIAL 2: With User Code With Electronic Key 1. Press the “F3” button 1. Pass three times a CHT key over a key reader 2.
  • Page 20 DISARMING (WITHOUT ALARM) With User Code With Electronic Key 1. Press the “#” button 1. Pass once a CHT key over a key reader 2. Digit the User Code (factory: “100000”) 3. A “beep” confirms arming, the LED on key reader switch 2.
  • Page 21 ERROR DURING DIGIT (FALSE CODE) The control panel checks is there are three errors during code digiting on keyboard. After the 3 error:  the keyboards are blocked for 2 minutes and on display appears “Keyb. Block”  a “False Code” SMS is sent and starts a “Theft” vocal call (more details on dialler manual) In case of two errors, 15 minutes are required to reset the “false code”...
  • Page 22 Alert To enable or disable the Alert signalling, follow next steps: At control panel disarmed, press the “” button: the user code. is required: 12:32 01/06/10 ▄ User Code  Disarmed ------ Digit the user code followed by “”. Digit the User Code User Code Confirm the change between on/off of the Alert ...
  • Page 23: Date And Time

    USER MENU Only the Master users can enter the User Menu. To enter in User Menu: Make a disarm of the system (even if it is already disarmed) Press “” Digit the User code (factory: 100000) Press “” Use the arrow keys () to move along the menu options, the “” button to enter and/or confirm a choice, the “”...
  • Page 24: User Programming

    EXCLUSIONS Bypass the selected zones at next arming. After each selection press “” to confirm. Exclusions Select the zone to bypass with the “” keys  Zone xx Press “” to bypass the zone: on display appears a X Press “” to include a bypassed zone USER PROGRAMMING Set the users on control panel.
  • Page 25 User block User cannot act on system (either with code or with key)  User can act on system according to its settings  Delete user Delete the user and restore its factory settings  Save actual user settings SYSTEM TES Verify wired zones and CHT keys working System Test To enter in test press the “...
  • Page 26 KEY READER FEEDBACK When control panel is on and disarmed the LED on key reader is normally OFF. The LED lights on to signals events: BLINKING Normal working TOTAL armed Alarm memory (at disarming, for 60 s) Green Normal working PARTIAL 1 armed One or more opened zones (at system disarmed) Blue...
  • Page 27: Sms Commands

    GSM-BUS EVENTS AND COMBINED MESSAGES Event on control panel Signalling Note Zone violation Alarm + eventual Opened Door Control panel Tamper Tamper Alarm No Power Line No Power Line Send 20 minutes after event (fixed time) Power Line Restored Power Back Send 5 minuti after event (fixed time) Low Battery Low Battery...

Table of Contents