Do you have a question about the XS6650 and is the answer not in the manual?
Questions and answers
Summary of Contents for Spotnails XS6650
Page 1
Take no ce to the schema c diagram included in this manual Please contact customer service to place an order for replacement parts: Operation, Maintenance Distributed by: BEST MATERIALS ® Ph: 800-474-7570, 602-272-8128 Fax: 602-272-8014 and Safety Manual www.BestMaterials.com Email: Sales@BestMaterials.com Pneumatic Tools PLEASE READ! This manual contains important information about product safety and should be read by all operators of this tool. Contact 1100 Hicks Road, Rolling Meadows, IL 60008 USA your Spotnails representative or distributor with any questions Phone: 847‐259‐1620 * 800‐873‐2239 Fax: 847‐259‐9236 * 888‐369‐2588 concerning the tool and its use. www.spotnails.com Spotnails 1100 Hicks Road, Rolling Meadows, Il 60008 1‐800‐873‐2239 ...
Warranty ……………………………………………. NOTE: Spotnails tools are quality built and designed to provide maximum performance when used with Spotnails fasteners. Spotnails cannot assume responsibility for performance if our tools are used with fasteners or accessories not meeting the same high ...
SAFETY INSTRUCTIONS ALWAYS DISCONNECT TOOL FROM AIR SUPPLY AND REMOVE FASTENERS Before opera ng this tool, all operators should read this manual to understand and FROM MAGAZINE PRIOR TO PERFORMING REPAIRS OR CLEARING JAMS follow all safety warnings before connec ng, disconnec ng, loading, opera ng, maintaining, changing accessories on, or working near the tool. Failure to do so can result in serious bodily injury or even death. Eye Protec on SYMPTOM CAUSE FIX The operator and all personnel in the general area should wear eye protec on that COIL NAILERS conforms to the requirements of ANSI Z87.1. Eye wear must provide protec on against flying par cles both from the front and side. 1. Dry piston feed 1. Add oil into air inlet in Hearing Protec on 2. Feed piston o‐rings 2. Replace o‐rings The operator and all personnel in the general area should wear hearing protec on in working area where exposure to loud noise level may cause hearing damage. 3. Check feed pawl to 3. Inspect pawl and wipe Skipping fasteners Hard Hat Protec on ...
OPERATION Do not use tool with missing or damaged safety warning labels ALWAYS DISCONNECT TOOL FROM AIR SUPPLY AND REMOVE FASTENERS Inspect the tool for proper opera on prior to use. Check for misalignment or binding of FROM MAGAZINE PRIOR TO PERFORMING REPAIRS OR CLEARING JAMS moving parts and any other condi on that may affect the tools opera on. Do not SYMPTOM CAUSE FIX overreach. Keep proper foo ng and balance at all mes. 1. Feed piston in need of 1. Lubricate feed piston Always assume that the tool contains fasteners and never hold or carry the tool with a lubricant finger on the trigger or point the tool at yourself or anyone else. Keep hands and body 2. O‐ring of feed piston worn 2. Replace o‐ring away from fastener discharge area of tool. Do not load tool with fasteners when any out one of the opera ng controls are ac vated. 3. Socket head cap stuck 3. Clean the obstacle that Never tamper with the safety device or use the tool if the safety device is not func oning block the cap properly. 4. Bumper worn out 4. Replace bumper if worn ...
EXPLOSION HAZARD TROUBLESHOOTING GUIDELINE Do not operate tool in explosive atmospheres, such as in the presence of flammable liquids, ALWAYS DISCONNECT TOOL FROM AIR SUPPLY AND REMOVE FASTENERS FROM gases or combus ble dust. Some tools will create sparks that can be an igni on source for MAGAZINE PRIOR TO PERFORMING REPAIRS OR CLEARING JAMS a fire or explosion. SYMPTOM CAUSE FIX AIR SUPPLY & CONNECTIONS 1. O‐ring/seals cut or worn 1. Replace O‐ring/seals Do not use air supply pressures that exceed 120 PSI Trigger valve (8.28 bar or 8.4 kg/mm’) housing/stem 2. Valve packing worn out 2. Replace trigger valve Use only clean, regulated compressed air as a power source for this tool. Do not use bo le leaks air assembly gases, combus ble gases or oxygen as a power source for the tool as the tool may explode. 1. Cap seal worn out 1. Replace cap seal Recommended opera ng pressure is 80 to 110 p.s.i. (8.28 bar or 8.4 kg/mm’) Do not exceed Cap or exhaust 2. Bolts on cap loose 2. Tighten the bolts the recommended maximum opera ng air pressure as tool wear will be greatly increased. cover leaks air The air supply must be capable of maintaining the opera ng air pressure of the tool. Pressure ...
TOOL SERVICE/MAINTENANCE LOADING Always handle tool with care. Clean and inspect your tool every me you use it Visually inspect the tool for worn or damaged parts prior to use. 1. Disconnect from air supply Tool service shall be repaired or equipped only with parts or accessories that are 2. Install a male, pneumatic fitting into the rear cap of the tool ensuring that the fitting supplied or recommended by Authorized Spotnails repair personnel. Service or repairs by allows the tool to exhaust any air in the tool when the air hose is disconnected. unqualified personnel may result in a risk of injury. 3. Add two drops of non‐detergent, 20‐weight oil into the male fitting. Please refer to the schema c drawing before star ng any repairs. 4. Connec ng the Air Hose a. Use a quick connect fi ng to the tool and check the air pressure reading on the Tool should be inspected periodically and replace any worn or broken parts to keep the tool opera ng safely and efficiently. regulator to ensure it does not exceed 120 p.s.i. Check the tool for any air leaks. b. Place the tool, empty of fasteners, in opera ng posi on on a scrap work piece. Tighten all screws. Loose screws can result in unsafe opera on of tool. ...
Need help?
Do you have a question about the XS6650 and is the answer not in the manual?
Questions and answers