Golden Blount CBF18VF+OMEGA18NM Installation And Operating Instructions Manual

Vent free gas logs

Advertisement

INSTALLER/CONSUMER RETAIN THIS APPLIANCE

INSTALLATION AND OPERATING INSTRUCTIONS

Burner Systems:
OMEGA18NM
OMEGA18LM
OMEGA24/30NM
OMEGA24/30LM
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Installation and service must be performed
by a qualified professional installer, service
agency, or the gas supplier.
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result, causing property
damage, personal injury, or loss of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS:
• Open a window
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
It is imperative that you maintain
your unvented gas appliance by
having it cleaned and served
regularly.
MANUAL WITH THE INSTALLED APPLIANCE
VENT FREE GAS LOGS
Read these instructions carefully and completely
before starting installation of burner system.
This appliance may be installed in an aftermarket,
permanently located, manufactured (mobile)
home where not prohibited by local codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This appliance
is not convertible for use with other gasses.
This is an UNVENTED gas-fired heater. It uses
air (oxygen) from the room which it is installed.
Provisions for adequate combustion and
ventilation air MUST be provided. See section
entitled COMBUSTION AND VENTILATION AIR.
This appliance is designed as an attended
appliance. Adults must be present when the unit
is operating. Do no leave this unit burning when
unattended or while anyone is sleeping.
Installation, service, and the provisions for
combustion and ventilation air MUST conform
with local codes and the National Fuel Gas Code,
ANSI Z223.1/NFPA54, or the CSA B149.1, Natural
Gas and Propane Installation Code.
1
DESIGN CERTIFIED
to standards:
Unvented Room Heater
ANSI Z21.11.2-2016
and
Vented Decorative Appliance
ANSI Z21.60-2017
Log Sets
CBF18VF
CBF24VF
CBF30VF
IMPORTANT
GBCBFVF-1017

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CBF18VF+OMEGA18NM and is the answer not in the manual?

Questions and answers

Summary of Contents for Golden Blount CBF18VF+OMEGA18NM

  • Page 1: Installation And Operating Instructions

    INSTALLER/CONSUMER RETAIN THIS APPLIANCE MANUAL WITH THE INSTALLED APPLIANCE INSTALLATION AND OPERATING INSTRUCTIONS VENT FREE GAS LOGS DESIGN CERTIFIED to standards: Burner Systems: Unvented Room Heater ANSI Z21.11.2-2016 OMEGA18NM Vented Decorative Appliance OMEGA18LM ANSI Z21.60-2017 OMEGA24/30NM Log Sets OMEGA24/30LM CBF18VF CBF24VF CBF30VF IMPORTANT...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PAGE Important Safety Information .
  • Page 4: Accessories

    SKY-1001 ON/OFF SKY-3003 ON/OFF THERMOSTAT/TIMER REMOTE CONTROL REMOTE CONTROL OMEGA 18NM Natural 32,500 26,000 10 .5” W .C . 5 .0” W .C . OMEGA 18LM Propane 32,500 26,000 13 .0” W .C . 11 .0” W .C . OMEGA 24/30NM Natural 40,000 34,000...
  • Page 6: Combustion And Ventilation Air

    MINIMUM FIREPLACE DIMENSIONS MODEL FRONT WIDTH BACK WIDTH DEPTH HEIGHT 18” 26” 22” 14” 20” 24” 32” 25” 14” 20” 30” 38” 25” 14” 20”...
  • Page 9: Pre-Installation And Fireplace Preparation Safety

    PRE-INSTALLATION AND FIREPLACE PREPARATION SAFETY CAUTION: Installation and repair must be done by a qualified professional installer. INSTALLER: Carefully read these instructions before installing this gas burner system. Be sure you understand all safety precautions and warnings contained in this manual. PRE-INSTALLATION AND FIREPLACE PREPARATION GUIDELINES: •...
  • Page 10: Installation Safety Information

    INSTALLATION SAFETY INFORMATION INSTALLATION SAFETY GUIDELINES: • Carefully inspect the burner and log cartons for shipping damage. If any parts are missing or damaged, call your dealer. Do not attempt to install the appliance unless all parts are in good condition.
  • Page 11: Operational Safety Information

    OPERATIONAL SAFETY INFORMATION OPERATING YOUR UNVENTED GAS APPLIANCE SAFETY AND CORRECTLY: • SOLID FUEL MUST NOT BE BURNED in a fireplace where this vent-free gas appliance is installed. • GLASS DOORS MUST BE FULLY OPEN when this vent-free gas appliance is operating. This appliance MUST NOT BE ON if glass doors are closed, as it can lead to sooting, burner outages, and possibly explosion, causing damage or injury.
  • Page 12: Operational Safety Information

    OPERATIONAL SAFETY INFORMATION (Cont.) OPERATING YOUR UNVENTED GAS APPLIANCE SAFETY AND CORRECTLY: • This appliance is intended for supplemental heating, and is not to be used as a primary heating source. Water vapor produced by vent-free burner systems can create moisture problems in a home when operated for extended periods of time.
  • Page 13: Charred Bonfire Logs Parts List

    CHARRED BONFIRE LOGS - PARTS LIST CBF18VF VENT FREE LOGS ITEM NO. DESCRIPTION Bottom Back Log Left Front Log Right Front Log Left Wing Log Right Wing Log Front Center Log CBF24/30 VENT FREE LOGS ITEM NO. DESCRIPTION Bottom Back Log Left Front Log (24”) Right Front Log (24”) Left Wing Log...
  • Page 14: Omega Burner Parts List

    OMEGA BURNER PARTS LIST OPTIONAL REMOTE CONTROLS SKY-3003 SKY-1001 On/off thermostat/timer remote On/off remote control (includes 4 control (includes 4 “AA” & 4 “AAA” “AA” Batteries) batteries . ITEM NO. DESCRIPTION ITEM NO. DESCRIPTION Omega 18 Burner Assembly Lava Rock Omega 24/30 Burner Assembly Platinum Brite Embers Control Valve (Specify Gas Type)
  • Page 15: Connecting Gas Line To Burner

    INSTALLATION - CONNECTING THE GAS TO THE BURNER SYSTEM BEFORE PROCEEDING, CAREFULLY READ ALL OF THE IMPORTANT SAFETY INFORMATION CONTAINED IN THIS OWNER’S MANUAL, INCLUDING: A. Pre-installation and Fireplace Preparation Safety Guidelines B. Ventilation and Confined Space Information C. Installation Safety Guidelines W A R N I N G Do not connect this appliance directly to a high pressure natural gas line or an unregulated L.P.
  • Page 16: Lava Rock And Glowing Ember Installation

    LAVA ROCK AND GLOWING EMBER INSTALLATION LAVA ROCK PLACEMENT Lava Rock is provided as an aesthetic enhancement to the Omega vent-free gas log set. Spread the lava rock on the floor of the firebox around the front and sides of the vent-free gas log set (Fig. 16-1). BE SURE THAT NO GRANULES ENTER THE MAIN BURNER OR INTERFERE WITH THE BURNING OF THE LOG SET.
  • Page 17: Log Placement Instructions

    LOG PLACEMENT INSTRUCTIONS WARNING: Failure to position these parts in accordance with these diagrams, or failure to use only parts specifically approved with this vent-free gas log set, may result in property damage or personal injury. CBF18 LOG PLACEMENT STEP 1: Place bottom back log on rear of STEP 2: Place left and right front logs on grate and center left to right .
  • Page 18 LOG PLACEMENT INSTRUCTIONS WARNING: Failure to position these parts in accordance with these diagrams, or failure to use only parts specifically approved with this vent-free gas log set, may result in property damage or personal injury. CBF24/30 LOG PLACEMENT STEP 1: Place bottom back log on rear of STEP 2: Place left and right front logs on grate and center left to right .
  • Page 19: Lighting Instructions

    LIGHTING INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, personal injury, or loss of life. Do not use this appliance if any part has been underwater. Immediately call for a qualified professional service technician to inspect the appliance and to replace any part of the control system and any gas control that has been underwater.
  • Page 20: Cleaning And Servicing

    CLEANING AND SERVICING Annual inspection and cleaning by your dealer or qualified ANNUAL CLEANING/INSPECTION - Refer to parts diagram for service technician is recommended to prevent malfunction and/ location of items discussed below: or sooting. • Inspect and clean burner air intake hole. Remove lint or TURN OFF HEATER AND ALLOW TO COOL BEFORE CLEANING.
  • Page 21: Operation Characteristics

    Front flames in the ember burner should be 1/4” above the embers. All Golden Blount vent-free gas log sets have been quality checked and tested to ensure proper operation and performance. Both combustion and performance results are satisfactory, before shipping.
  • Page 22: Troubleshooting

    TROUBLESHOOTING - SYMPTOMS & POSSIBLE CAUSE AND CORRECTIONS Turn appliance OFF and allow to cool before servicing. Only c. Manual Shutoff valve not fully open - Fully open a qualified service person should service and repair heater. manual shutoff valve. d.
  • Page 23: Warranty

    Defective logs or defective parts should be returned to your dealer or to the factory prepaid with a copy of your sales receipt . Defective parts will be repaired or replaced at the factory’s option and returned to you prepaid . GOLDEN BLOUNT INC . - 4301 WESTGROVE DRIVE - ADDISON, TX 75001...

Table of Contents

Save PDF