Peterson Instruments SA-77 Instructions And Operating Manual

Peterson Instruments SA-77 Instructions And Operating Manual

Liquid accumulator

Advertisement

Liquid Accumulator
• Flow Meter Not
Required
• Environmentally
Friendly
• Anti-Spill Interlock
• Two Moving Parts
• Extremely Low
Maintenance Cost
• Single and Multi-
Stroke Versions
Available
The Premium Liquid Sampler
Oil and Gas; Water Treatment; Waste Treatment and More
SA-77
Meeting the needs of Industry
One Sample at a Time
Ph: 1-800-667-7993

Advertisement

Table of Contents
loading

Summary of Contents for Peterson Instruments SA-77

  • Page 1 SA-77 Liquid Accumulator • Flow Meter Not Required • Environmentally Friendly • Anti-Spill Interlock • Two Moving Parts • Extremely Low Maintenance Cost • Single and Multi- Stroke Versions Available The Premium Liquid Sampler Meeting the needs of Industry One Sample at a Time Oil and Gas;...
  • Page 2: Specifications

    SA-77 Liquid Sampler: Drawings and Parts List Ph: 1-800-667-7993 Specifications: Materials: All wetted parts are 316 SST, Delrin, Viton (&/or Aflas). Operating Pressure: Standard Max: 750 psi (5171 kPag) High Pressure Option: 1440 psi (9928 kPag) Receivers: 1.8 L HDPE or 1.8 L Glass...
  • Page 3: Installation

    SA-77 Liquid Sampler: Drawings and Parts List Ph: 1-800-667-7993 Installation: Mounting Using the 2 pipe clamps (supplied) mount on a 2” vertical or horizontal pipe. Or use lag screws (not supplied) to mount to wall. Supply or Signal Connection (on the left side of the Manifold Assembly) For the Multi-Stroke models connect a clean instrument supply of 5 to 20 psi to the 1/8"...
  • Page 4: Sample Probe Installation

    SA-77 Liquid Sampler: Drawings and Parts List Ph: 1-800-667-7993 Sample Probe Installation (Industry Best Practice Sharing) ! Probe weld-o-lets should be placed on the side of the pipe at center, so the probe quill sits in the horizontal plane. ! If the choice is available mount in vertical piping flowing upwards.
  • Page 5: Operation

    SA-77 Liquid Sampler: Drawings and Parts List Ph: 1-800-667-7993 Operation: Run / Stop (See General Overview Drawing this page- Control Valve) To start the Accumulator push the knob in. To stop the Accumulator pull the knob out. Note: when the Accumulator’s jar is full, pressure from the sample line will push this knob out and stop the Accumulator.
  • Page 6 SA-77 Liquid Sampler: Drawings and Parts List Ph: 1-800-667-7993 SA-77 Liquid Valve Assembly Part Number: SA-7701ASSY Item Description Material Part No. Qty. Valve Block -Liquid Valve SA-77011 Screw 6-32 x 318” SA-77011A Liquid Valve Piston Chamber Anodized Al. SA-77012 0-ring Piston Chamber to Body...
  • Page 7 SA-77 Liquid Sampler: Drawings and Parts List Ph: 1-800-667-7993 SA-77 Control Valve Assembly Part Number: SA-7702ASSY Item Description Material Part No. Qty. Valve Block(Control) Start/Stop SA-77021 End Block - 316 Sst SA-77005 End Block Seal Viton/Aflas SA-77005A End Block Mtg.Screw 6-32x1"...
  • Page 8 SA-77 Liquid Sampler: Drawings and Parts List Ph: 1-800-667-7993 SA-77 Sizer Assembly Part Number: SA-7703ASSY Item Description Material Part No. QTY. Sizer Adjusting Cap SA-77031 Sizer Cap Thumb Screw Brass SA-77032 Sizer Piston Spring SA-77033 Sizer Body SA-77034 Sizer Mtg Screw Hex Socket...
  • Page 9 SA-77 Liquid Sampler: Drawings and Parts List Ph: 1-800-667-7993 Weight Actuated Shutoff-Plastic Assembly Part Number: SA-7704ASSY Item Description Material Part # Qty. Valve Body SA-77041 Valve Body Bushing;3/8-1/4 77041A Stem Seal Oring Viton 77043A Rain Cap Guard Polyurethane SA-77042 Lid Aluminum-Bottle Holder Anodized Al.
  • Page 10 SA-77 Liquid Sampler: Drawings and Parts List Ph: 1-800-667-7993 SA-77 Oscillator Assembly Part Number: SA-7708ASSY Item Description Part No. Humphrey Relay Valve SA-77081 1/8”P Adjustable Flow Check Valve SA-77082 1/4”TX1/8”P Female Connector SA-77083A 1/4”T x1/8"P Male Elbow SA-77084 1/4” Male Tube Adapter SA-77085 Restrictor M/F for Osc.
  • Page 11: Ordering Information

    SA-77 Liquid Sampler: Drawings and Parts List Ph: 1-800-667-7993 Ordering Information Example: SA-77SXAPX SA-77 S X X P X SA-77__ __ __ __ __ External Mounting Kit: Model: Standard 2" Pipe: X Single Stroke: For 3" Pipe: 3 For 4" Pipe: 4 Multi Stroke: For 6"...
  • Page 12 SA-77 Liquid Sampler: Drawings and Parts List Ph: 1-800-667-7993 Supplying Industry With Orifice Plates, Charts, Pens, Meters, Meter Saddles, Samplers, Wellhead 123, 5655 – 10 Street NE Controllers, Gas Metering Parts, Calgary, AB T2E 8W7 HLR Pressure Switches & Relays,...
  • Page 13 SA-77 Liquid Sampler: Drawings and Parts List Ph: 1-800-667-7993 Sonceboz Garzo Corporation Compressor Accessories CDS820 Battery Oil Level Control Boxes Chart Drive Cooler Louver Actuators “The Red Lube Oil Low Flow Meters One” Chart Hubs Foxboro Chart Drives CDS830 Fast/Slow two speed...
  • Page 14 SA-77 Liquid Sampler: Drawings and Parts List Ph: 1-800-667-7993 SWI-015 SA-77 Manual-2.docPage 14 of 24 Rev: 0.
  • Page 15 SA-77 Liquid Sampler: Drawings and Parts List Ph: 1-800-667-7993 Water-Cut (BS&W) Procedure Obtaining accurate water-cut (BS&W) percentage during well proration testing is an important aspect of oil well measurement and accounting because it directly affects the oil volume determination. However, it is one that is frequently overlooked.
  • Page 16 SA-77 Liquid Sampler: Drawings and Parts List Ph: 1-800-667-7993 Water-Cut (BS&W) Procedures (cont.) For 0% to 10% BS&W 1. Obtain a representative sample of liquid (minimum 500 ml). Sample should be taken as close to the test meter as possible.
  • Page 17 SA-77 Liquid Sampler: Drawings and Parts List Ph: 1-800-667-7993 SWI-015 SA-77 Manual-2.docPage 17 of 24 Rev: 0.
  • Page 18 SA-77 Liquid Sampler: Drawings and Parts List Ph: 1-800-667-7993 Water-Cut (BS&W) Procedures (cont.) For 10% to 80% BS&W 1. Obtain the maximum representative sample of liquid feasible (between 800 and 1000 ml). 2. Transfer the entire sample into an adequately sized graduated cylinder.
  • Page 19 SA-77 Liquid Sampler: Drawings and Parts List Ph: 1-800-667-7993 SWI-015 SA-77 Manual-2.docPage 19 of 24 Rev: 0.
  • Page 20 SA-77 Liquid Sampler: Drawings and Parts List Ph: 1-800-667-7993 Water-Cut (BS&W) Procedures (cont.) For 80% to 100% BS&W 1. Obtain the maximum representative sample of liquid feasible (between 800 and 1000 ml). 2. Transfer the entire sample into an adequately sized graduated cylinder.
  • Page 21 SA-77 Liquid Sampler: Drawings and Parts List Ph: 1-800-667-7993 Recommended Rates and Pressure Drops for Liquid Meters When evaluating fluid measurement systems, it is important to first determine if the control or dump valve is a snap-acting type valve. By having snap-acting control, as well as having a properly...
  • Page 22 SA-77 Liquid Sampler: Drawings and Parts List Ph: 1-800-667-7993 SWI-015 SA-77 Manual-2.docPage 22 of 24 Rev: 0.
  • Page 23 SA-77 Liquid Sampler: Drawings and Parts List Ph: 1-800-667-7993 123, 5655 – 10 Street NE Calgary, AB T2E 8W7 Ph: 403-291-9169 Fax: 403-291-0960 Website: www.petersoninst.com SWI-015 SA-77 Manual-2.docPage 23 of 24 Rev: 0.
  • Page 24 SA-77 Liquid Sampler: Drawings and Parts List Ph: 1-800-667-7993 SWI-015 SA-77 Manual-2.docPage 24 of 24 Rev: 0.

Table of Contents