3.2.1 Parameters selection

First, confirm measuring parameters should suitable for
your requirements.
a) Measurement Mode.
There are two modes: Single Mode
and Continuous
Mode
. It's displayed in the upper left corner of the LCD

display.

It is usually to choose Single Mode, that is, when a
measurement is completed, you should lift the probe and
then the next point measurements. In this mode, the
measurement data can be stored automatically and
calculate mean value.
Select "Continuous Mode", you can slide the probe on
measuring surface for measurement continuously.
However, this mode will not perform the data storage and
statistical processing.
b) Measurement Units
The instrument has two kinds of units available for
selection: μm (microns) and mils (micro inch).

3.2.2 Accuracy verification

a) Using a calibration substrate and Standard thickness foil
to verificate the instrument. Generally if the

measurement

error is not out of the accuracy of specifications it can be
used normally.
Methods:
Select a Single Mode and μm, press the probe on the
surface of the substrate, push
for zeroing. Place a foil
4
Contents

1 Introduction

2 Description

2.1 Gauge

2.2 Display

2.3 Specifications

3 Operation

3.1 Power on/off

3.2 Measuring Procedure

1 Introduction
Designed for non-destructive coating thickness
measurement, the models of the coating thickness gauge
is with built-in sensor. It works on the magnetic induction
principle and conforms to the following industrial norms
and standards: GB/T 4956, JB/T 8393, ISO 2178, ASTM
B499
The Coating Thickness Gauge is suitable for
non-destructive, quick and precise coating thickness
measurement. Easy to handle they are the ideal
1
on the substrate to measure. Comparing the measured
value and the standard value of the foil to obtain the
measurement error.
b) If the error is large, the calibration is need for, (see 5.1
Calibration).
3.2.3 Test piece ready
a) Test-piece should be ferromagnetic base material is
coated with a non-magnetic coating;
b) The measuring surface should be regular, smooth;
c) The thickness of the test piece is not less than 2mm;
d) The measuring surface should be clean and free of
grease.
3.2.4 Measurement
Press the probe perpendicular to
the surface of the test piece (Fig.
3-1).
When the thickness values is
obtained, a sound is uttered.
In Single Mode, then you can lift
the instrument to read, or do the
next measurement.
In Continuous Mode, then you
can move the probe to the next
measurement position.
Fig. 3-1
NOTE:
In Single Mode, you need to lift the
5
instrument for the finishing industry, electroplating, ship
and bridge building, aircraft construction and the
engineering and chemical industry.
The Coating Thickness Gauge works on the
1
magnetic-induction principle for measuring the thickness
2
of non-magnetic coatings(such as paint, enamel, rubber,
2
aluminum, chrome, cupper, tin etc.) on magnetic metal
2
substrates(ferrous bases and steel, also on alloyed steel or
3
on hardened magnetic steel, but not on austenitic steel or
3
3
weak magnetic steel).
3
7
2 Description
8
2.1 Gauge
9
11
11
LCD
Power
/ Zero
14
Keypad
Mode
Single
Continue
Probe
Measured
Value
Measured
Fig. 2-1
Point
2.2 Display
(Fig.2-3)
2
instrument away from the test surface 10cm or more, and the
time interval between two measurements should be no less than
1 second.
Use Continuous Mode often, may cause the probe wear
and galling test surface is easy. We therefore recommend
to use Single Mode for normal measurements, if not
necessary.

3.2.5 Data read and browse

a) Read measuring value
Read the measured value from the LCD. (Fig. 3-2)
Measuring
value
Measured
Points
Fig.3-2
NOTE:
The maximum points for the statistical set is 9. It will start the
next statistics set automatically if more than 9 points. Enter the
menu or push
will renew statistical set and average.
b) Data Browse
In Single Mode, each measuring value is stored
automatically
In the
No.
measuremen
t mode, you
can press
to
Fig.3-3
6
2.3 Specifications
Test Method:
Measuring Range:
Resolution:
1μm
Accuracy:
Data Memory:
Display:
Operating temperature :
Dimension:
Weight:
Up
3 Operation
Menu
3.1 Power on/off
Push
until the power is turned on.
Down
NOTE: If there are magnetic metals near the probe at the moment
of swatch on, the gauge will display a alarm "Surround
Fig. 2-2
Error!".Should take gauge far from magnetic metals and wait few
seconds it can go normal.
Battery
When the gauge is switched on, press
the power off.
NOTE: This gauge can power off automatically, if no any operation
for 3 minutes. Before turning off, it will sound for a few beep
prompt. If you do not want to power off, simply press any key can
abort.
Mean
Value
Fig. 2-3
3.2 Measuring Procedure
browse them. (Fig. 3-3)
Press
for page up and down.
Press
to exit the browser and return to measurement
mode.
NOTE: The gauge can store up to 500 of measurement value. The
greatest number is the most recent measurement.
After the data store reaches 500, the following data will be stored
and pile out the first data automatically. Therefore, record the
useful data as soon as possible for not to lose.
3.2.6 Passing measurement
a) In the Single Mode, you can also be set upper and lower
Mean
limits for passing judgment and screening tests.
Value
b) When the measured value exceeds the tolerance, it will
sound indication.
c) To set upper and lower limits, see 4.1.2 Upper and
Lower Limits.
The gauge uses a menu for
setting the parameters or
the functions.
The structure of setup
Thickness
menu is shown in Fig 4-1.
In the measurement mode,
press the "Menu"
to
enter the setup menu.
Press the "Up"
or
Magnetic induction
0~1250mm (0 ~50mil)
0 ~ 999μm: 0.1μm, ≥1000μm:
up to 100μm: ±2.5μm; 100 ~
1500 μm: ≤ 2.5 %
up to 500 readings.
Graphic LCD with backlight
0 ~ 50°C
150X50.5X29 mm
170 grs
a while to turn
3
4 Setup
Fig. 4-1
7

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CF1250 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Accud CF1250

  • Page 1 “Surround Fig. 2-2 Single Error!".Should take gauge far from magnetic metals and wait few Designed for non-destructive coating thickness CF1250 Continue seconds it can go normal. Battery measurement, the models of the coating thickness gauge...
  • Page 2 4.1.2 Upper and lower limit settings and key tone (Sound). 4.2.3 Key Tone "Down" ("Up" or "Down" the same below) If the limits are set up and turn on, when the measuring (Fig. 4-6) can select a item, press "OK" to enter the selected value exceeds the limit, the 4.2.1 Unit...

Table of Contents