Pure Water Whisper 60 User Manual

Pure Water Whisper 60 User Manual

Whisper 60 modular 12/24 volt dc 230vac

Advertisement

Quick Links

PureWater – H. Fehlemann
Entsalzungsanlagen
Bodelschwinghstrasse 37
33142 Büren
Germany
Whisper 60 modular
www.watermaker.de
Whisper 60 modular
12/24 Volt DC 230VAC
User Guide and Installation handbook
purewater@watermaker.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Whisper 60 and is the answer not in the manual?

Questions and answers

Summary of Contents for Pure Water Whisper 60

  • Page 1 Whisper 60 modular Whisper 60 modular 12/24 Volt DC 230VAC User Guide and Installation handbook PureWater – H. Fehlemann Entsalzungsanlagen Bodelschwinghstrasse 37 33142 Büren Germany www.watermaker.de purewater@watermaker.de...
  • Page 2: Table Of Contents

    Index General Theory of Operation………………………………………………………... Whisper 60 modular……………………………………………………………… The general scope of application…………………………………………… Explanation………………………................2.3.1 ETD Connections………………………………………………………………………. Quality Monitor……………………………………………………………………….. Performace……………................... Installation……………………………………………………………………………… Preparation for Installation ………………………………………………………… 4.3.1 Feed Pump, Pre-Filter and Hose connections…… ……………………………..4.3.2 Product Water connection…………………………………………………………… Hose connections to PH Stabilizer (Only COMPACT Models)………….
  • Page 3 Whisper 60 modular Guide The Whisper 60 modular, individual parts: Basic Unit Filtersystem Whisper Feed Pump Vane Pump 230V Main Panel Pressure Vessel The dimensions of Motor and pump are subject to change, because different motors are used.
  • Page 4 Whisper 60 modular Guide Vorsichtsmaßnahmen Precautionary Bitte beachten Sie folgende Punkte bevor Sie Ihre Whisper Anlage einbauen und in Betrieb nehmen! Please pay attention to the following point’s bevor you install the system. 1. Die Anlage sollte innerhalb von 12 Monaten nach Auslieferung in Betrieb genommen werden.
  • Page 5: General Theory Of Operation

    In this type of system, the concentrated solution (normally referred to as feed-water) will become more concentrated as pure water flows out of solution and across the membrane to the permeate side. Discounting the effects of feed-water temperature and salinity, the operating pressure normally required to produce significant amounts of pure water is at least twice the osmotic pressure of the membrane being used.
  • Page 6: The General Scope Of Application

    Whisper 60 modular Guide In a Reverse Osmosis desalination system, most of the dissolved solids do not pass through the Membrane but are instead carried along the membrane surface. This rejected water, referred to as Brine, becomes increasingly more concentrated as it flows across the surface of the membranes and is eventually piped to drain.
  • Page 7: Explanation

    Whisper 60 modular Guide 2.3 Explanation High Pressure Gauge (at the ETD) The High pressure Gauge shows the operating pressure. The range is between 35 and 55 Bar. That depends of the type of Membrane installed. Generally we are using low energy membranes, so the pressure is about 35-45 Bar.
  • Page 8: Quality Monitor

    Whisper 60 modular Guide 2.4 Quality Monitor (COMPACT Versions) The Quality Monitor shows the quality of the product water in PPM TDS (Part per Million Total dissolved Solids) When starting the system the quality is always for a short period ( 30-45sec) high salinity. Shortly the monitor starts to count down.
  • Page 9: Performace

    Whisper 60 modular Guide 3.0 Performance Sea Star Whisper 60 modular Weight: 55 Kg Power consumption: Whisper 90 12V – 21-24A 24V- 11-12A 230V 3,5A Product Flow: 60 L/h +/- 10% Operational Parameter: Pressure: High Pressure: 500-950psi 35-55 Bar Low Pressure: 7-12 Bar Maximum Salinity: 46000 ppm (ppm= Parts per million) Temperature Range: 1°...
  • Page 10: Preparation For Installation

    Whisper 60 modular Guide 4.2 Preparations for Installation For installation pay attention to the Flow Diagram on Page 16 and 17 Sea Water Filter (Strainer) Place the Strainer direct after the Sea Cock. The Strainer has a 60µ washable Filter inside.
  • Page 11: Feed Pump, Pre-Filter And Hose Connections

    Whisper 60 modular Guide 4.3.1 Feed Pump, Pre- Filter and Hose connections The Sea Water feed should be a marine grade Sea Cock, that you can close the Sea Cock individually. The sea water inlet should be a scoop type, that the water is pressed in during cruise.
  • Page 12: Product Water Connection

    Whisper 60 modular Guide Hose Connections to PH Stabilizer (Only COMPACT Models, or Option) Step 1 The Pre – Filter installation is completed Step 2 The Product Water outlet at the Manifold has to be connected with the PH Stabilizer.
  • Page 13: Electric Control Box (Option)

    Whisper 60 modular Guide 4.4 .1 Electrical Control Box with Relay 12/24V DC Warning! Disconnect power from the system. Cable to the feed Batteriy pump. Blue or red is Positive Positive Black is always Negative Power Relay Battery Negative Cleats for the control cable to the main switch.
  • Page 14: How To Use The System

    Whisper 60 modular Guide 5.0 How to use the system 5.1 Filling and starting the system. Step1 Place the Sample Valve in Pos. SAMPLE and guide the hose to a drain. (Not for COMPACT Models) Step 2 Open the Sea Cock and let water flow into the system.
  • Page 15: Preservation Configuration Flow Diagram

    Whisper 60 modular Guide Flow Diagram Preservation Configuration...
  • Page 16: Maintenance

    Whisper 60 modular Guide 6.0 Maintenance 6.2 Short Term Storage/Fresh Water Flush Ideally, the SEA STAR Whisper performs optimally when the RO unit is used periodically. However, the Likelihood of bacterial and biological growth in the membranes increases, when stagnant seawater (in extended periods) is in contact with the membranes.
  • Page 17: Long Term Storage / Preservation Procedure

    Whisper 60 modular Guide Long Term Storage/Preservation During periods when the RO unit is to be shut down for an extended period of time, it is necessary to re-flush the unit every three month OR to circulate a preservative solution through the membrane to prevent the growth of biological organisms.
  • Page 18: Membrane Replacement

    Whisper 60 modular Guide Membrane Replacement End-Cap Membrane Brine Seal Pressure Vessel End- Cap End-Cap with connections. To open the pressure vessels, you need a 5mm face spanner. With that tool you can turn the End-Caps out. Prepare the Membranes Seal in the same position as the old Membrane. Most probably you have to change the seal at the new membrane to the opposite position.
  • Page 19: Flow Diagram With Air/Oil Separator

    Whisper 60 modular Guide Flow Diagram with Air/Oil Separator...
  • Page 20: Flow Diagram Standard Configuration

    Whisper 60 modular Guide Flow Diagram Standard Configuration...
  • Page 21: Wiring

    Sea Star Handbuch Elektrische Schaltung Wiring Batterie + ( 10mm Bolzen ) 24V DC units have a converter 24V – 12V Control Cable 1 24V+ Plus Ein – Aus Schalter Motor Feed Pump Plus (red) 12/24 Volt Schaltrelais Batterie Control Cable 3 Motor Feed Pump Minus Schwarz Batterie ,Minus Control Cable 2+4 - Minus...
  • Page 22: The John Guest System

    Whisper Handbook 9.1The John Guest System...

Table of Contents