Digital Monitoring Products 1154 Installation Manual

Wireless four-zone input module

Advertisement

Quick Links

1154 WIRELESS FOUR-ZONE INPUT MODULE
Installation Guide
Figure 1: 1154 Housing
DESCRIPTION
The 1154 Wireless Four-Zone Input
Module is designed to convert up
to four existing normally closed,
hardwired zones (such as motion
sensors, door & window contacts,
etc.) into wireless zones.
When a DMP panel is installed in
a location with an existing non-
DMP panel, then the 1154 can be
connected to the existing panel's
12 Volt auxillary power. Once
connected, the 1154 Wireless Input
Module converts up to four existing
hardwired zones into wireless zones.
This allows the new DMP panel to
communicate with the existing zones.
All DMP 1100 Series Wireless
Receivers and burglary
panels. See the last page for
compatibility details.
What is Included?
• 1154 Wireless Four-Zone Input Module
• 3V Lithium CR123A battery
• Hardware pack
Optional items:
• Model 376L DC Power Supply
• Model 505-12 12VDC Power Supply
1

PROGRAM THE PANEL

The 1154 can be programmed with up to four zones. When
programming the 1154 in the panel, refer to the panel
programming guide as needed.
1.
In ZONE INFORMATION, enter the ZONE number, and
then press CMD.
2. Enter the ZONE NAME and press CMD.
3. Once ZONE TYPE appears, select the appropriate
zone type, and then press CMD.
4. At the NEXT ZONE prompt, select NO. If you see the
WIRELESS ZONE prompt, select YES.
Note: If you are programming the 1154 onto a
zone that can be either hardwired or wireless,
then this prompt appears. If the zone you are
programming is wireless-only, then the prompt
does not appear.
5. Enter the eight-digit SERIAL NUMBER and press CMD.
6. Enter the CONTACT number being used.
7.
Enter the SUPERVSN TIME and press CMD.
8. At the NEXT ZONE prompt, select YES and continue
to program up to three more zones.
Note: Zones must be entered sequentially. For
example, if you begin by programming zone 71,
you would need to program zone 72 as the next
contact.
2

MOUNT THE 1154

The 1154 Wireless Input Module should be placed close to
the existing non-DMP panel.
With the 1154's housing cover removed, use the supplied
screws to secure the 1154 to a wall or other flat surface. The
1154 PCB has built-in holes to allow you to screw the housing
onto a surface without removing the PCB. See Figure 2.
Power Source
Selector Pins
Input Power
Terminal Block
+
3V
Lithium
Battery
-
Zone Wiring
Figure 2: 1154 Wireless Input Module PCB
Mounting Holes
Terminals
LT-1619 © 2017 Digital Monitoring Products, Inc.
17351

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1154 and is the answer not in the manual?

Questions and answers

Summary of Contents for Digital Monitoring Products 1154

  • Page 1 This allows the new DMP panel to screws to secure the 1154 to a wall or other flat surface. The communicate with the existing zones. 1154 PCB has built-in holes to allow you to screw the housing onto a surface without removing the PCB.
  • Page 2 Option A: Power from an Existing Panel If the 1154 is powered from an existing panel, the existing panel must be connected to AC power. Powered zones connected to the 1154 may need to be connected to the existing panel for power.
  • Page 3 Option B: External DC Plug-In Power Supply When using the optional Model 376L plug-in DC power supply, mount the 1154 near a wall outlet or other power Input Power source. Terminal Block Place the supplied jumper on the two power source Black Black &...
  • Page 4 Code de sécurité 6 de Santé Canada. Le système doit être installé à une distance minimale de 7.87 pouces (20 cm) séparant l’antenne d’une personne présente en conformité avec les limites permises d’exposition du grand public. 1154 Wireless Four-Zone Input Module...