IF-80x Outdoor Slave Terminal
Thank you for choosing a product from Interflex. With this product, you have purchased a reliable device for
access control.
1.1 Scope of delivery
IF-80x Outdoor terminal (slave)
I/O controller board for controlling locking devices
Material for fastening
8-pin terminal strip
Blue wire for grounding the back panel
Mortise lock
Plastic strips for sealing the mortise lock
Adhesive tape for mounting the I/O controller board
Please check the completeness and condition of the
shipment upon receipt.
1.2 CE conformity
The device complies with the requirements of the respective EU guidelines (CE conformity).
Modifications to the device are not permitted.
All information contained in this documentation is accurate at the time of printing. All specifications are
subject to change without notice.
The product brand names and trademarks specified in this documentation are protected by commercial and
patent laws.
1.3 Shielded cables
To ensure malfunction-free operation, we recommend the use of shielded bus cables.
Operation is also possible with unshielded cables. In case of transmission problems, you will have to
examine the reasons in each individual case. Where necessary, a shielded cable should be used for the
connection of the respective devices.
1.4 Intended use
The device is used for reading RFID credentials, e.g. in access control systems, and also for controlling
locking devices. Any other use is not in accordance with the intended purpose and is therefore not permitted.
1.5 Function
Slave terminals of series IF-80x Outdoor are used for:
controlling the access of people who identify themselves via an RFID credential before entering a
security zone.
controlling and monitoring locking devices that prevent uncontrolled (physical) access to security zones.
writing NetworkOnCard access rights. The data is used for identification at offline devices, e.g. electronic
door fittings.
Interflex Datensysteme GmbH
1/13

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IF-80x and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Interflex IF-80x

  • Page 1 95-10330 V2017-07-24 IF-80x Outdoor Slave Terminal Thank you for choosing a product from Interflex. With this product, you have purchased a reliable device for access control. 1.1 Scope of delivery IF-80x Outdoor terminal (slave)  I/O controller board for controlling locking devices ...
  • Page 2: Assembly And Installation

    1.6 Function of the IF-80x outdoor terminal Terminals of the IF-80x Outdoor series are part of an access control system. They are preferably installed directly next to locking devices. They are generally connected to a master terminal, access manager or terminal controller via an RS485 data cable.
  • Page 3: Installation

    3 Installation 3.1 Mounting the IF-80x outdoor terminal Recommendation: Install the terminal at a height of approx. 125 cm (distance from floor to bottom edge of the terminal). Mounting holes Vertical mounting option with DIN appliance case Alternative mounting hole for wall-mounted cable...
  • Page 4 Ensure short cable routing. Cable loops can damage the device due to mechanical stresses. Tighten the screw only slightly or leave it out. Tightening the screw too tightly can result in mechanical stresses which can damage the device. Interflex Datensysteme GmbH 4/13...
  • Page 5 The drain wire must have an electrical connection to The cable lug of the blue wire is connected to the the back panel of the housing. strain relief. Lug for fastening the wall reader with the M2x6 mm Lug for mortise lock screw Interflex Datensysteme GmbH 5/13...
  • Page 6: Electrical Connections

    PoE or from an external power supply unit. Power supply to I/O controller board Data cable from I/O controller board to IF-80x Outdoor terminal Patch cable from computer to switch or hub...
  • Page 7 Screw down the terminal on the bottom left side (11) using the M2 x 6 mm countersunk screw included in delivery. Insert the mortise lock on the bottom right side and lock the terminal (13). Use the enclosed plastic strips to seal the mortise lock. Interflex Datensysteme GmbH 7/13...
  • Page 8: Wiring Overview

    4.3 Wiring overview 1 IF-80x Outdoor terminal 5 Circuit example: Control of an actuator (door opener). The actuator may only be operated with max. 30 V and 2 A. 2 I/O controller board 6 Circuit example: Connection of both inputs.
  • Page 9 Reduce the length of the COM cable, if necessary, to ensure that the total length of 100 m is not exceeded. Example: The IF-80x Outdoor terminal is connected to I/O controller board 1 by a 30-meter-long cable. The cable for the connection of I/O controller board 2 may not be longer than 70 m. Interflex Datensysteme GmbH...
  • Page 10: Device Settings

    Use the address switch to set the hardware address of the device. Switch Address 1 OFF (not required if connected to a master terminal) Address 2 Address 3 Address 4 Address 5 Address 6 Address 7 Address 8 Interflex Datensysteme GmbH 10/13...
  • Page 11 6.2 Setting the address without an I/O controller board If an I/O controller board without an address switch is used, you can set the address of the IF-80x Outdoor terminal via the RS-485 data cable. Once the terminal is connected to the controller, it responds with host address 8.
  • Page 12: Initial Operation

    See also Wiring Overview ........................8 7 Initial Operation Once you have connected the IF-80x Outdoor terminal and set the address, lock it using the mortise lock. Additionally fasten the device with the included M2 x 6 mm countersunk head screw.
  • Page 13: Technical Specifications

    130.5 x 87 x 24 Weight 0.5 kg 9 EU Declaration of Conformity Interflex hereby declares that the products comply with the directives 2014/53/EU and 2011/65/EU. The complete EU Declaration of Conformity is available at the following Internet address: www.interflex.de/en/header/downloads/ce_declaration_of_conformity.html...

Table of Contents