BD ASM 400 Operating Manual page 13

Display and switching unit
Table of Contents

Advertisement

Menu 12 – Hysteresis and compare mode of set point 2
Menu 13 – Setting the switch-on delay for set point 1
Menu 14 – Setting the switch-off delay for set point 1
Menu 15 – Setting the switch-on delay for set point 2
Menu 16 – Setting the switch-off delay for set point 2
13
active
inactive
Fig. 7 Hysteresis mode
After confirming "HY 2 " resp. "CP 2" by pushing both buttons, you
can choose between hysteresis and compare mode for contact 2.
To complete the setting, push both buttons simultaneously.
Please take further information from the figures in menu 11.
After confirming "d1on" by pushing both buttons, the switch-on
delay after reaching contact 1 can be set. The time can be set
from 0 to 100 seconds. To complete the setting, push both buttons
simultaneously.
After confirming "d1of" by pushing both buttons, the switch-off
delay after reaching contact 1 can be set. The time can be set
from 0 to 100 seconds. To complete the setting, push both buttons
simultaneously.
After confirming "d2on" by pushing both buttons, the switch-on
delay after reaching contact 2 can be set. The time can be set
from 0 to 100 seconds. To complete the setting, push both buttons
simultaneously.
After confirming "d2of" by pushing both buttons, the switch-off de-
lay after reaching contact 2 can be set. The time can be set from 0
to 100 seconds. To complete the setting, push both buttons simul-
taneously.
active
inactive
Fig. 8 Hysteresis mode
inverted
www.bdsensors.de
ASM 400