Solar Fires and Fireplaces LANDSCAPE 22 Installation And Servicing Instructions

22" hot box coal-log effect gas fires and remote control natural gas and lpg models

Advertisement

INSTALLATION AND SERVICING INSTRUCTIONS
THESE INSTRUCTIONS SHOULD BE RETAINED BY THE USER FOR FUTURE REFERENCE
THIS APPLIANCE MUST BE INSTALLED/SERVICED BY A COMPETENT PERSON
IN ACCORDANCE WITH ALL THE REGULATIONS IN FORCE
THIS PRODUCT IS APPROVED TO THE EUROPEAN GAS APPLIANCE DIRECTIVE
This appliance is identified by the Serial Number. The Serial Number is found at the
top of the data plate to the right of the control knob. This serial number must be
NB
PRIOR TO INSTALLATION, ENSURE THAT THE LOCAL DISTRIBUTION
CONDITIONS (IDENTIFICATION OF THE TYPE OF GAS AND PRESSURE) AND THE
ADJUSTMENT OF THE APPLIANCE ARE COMPATIBLE.
The use of a fireguard conforming to BS 6539 is recommend when the appliance is
used in the presence of young children, the elderly or infirm.
The countries of destination are GB & IE.
Solar Fires and Fireplaces, Alyn Works, Mostyn Road, Holywell, Flintshire, CH8 9DT
SOLAR 22" HOT BOX
LANDSCAPE 22
COAL\LOG EFFECT GAS FIRES
AND REMOTE CONTROL
NATURAL GAS AND LPG MODELS
quoted in all correspondence.
Tel 01745 561685 Fax 01745 560987

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LANDSCAPE 22 and is the answer not in the manual?

Questions and answers

Summary of Contents for Solar Fires and Fireplaces LANDSCAPE 22

  • Page 1 The use of a fireguard conforming to BS 6539 is recommend when the appliance is used in the presence of young children, the elderly or infirm. The countries of destination are GB & IE. Solar Fires and Fireplaces, Alyn Works, Mostyn Road, Holywell, Flintshire, CH8 9DT Tel 01745 561685 Fax 01745 560987...
  • Page 2: Section One Installation

    SECTION ONE INSTALLATION LIST OF COMPONENTS 1) Hot box with brass trim 2) 22" HOT BOX Burner Unit 3) Ceramic Pieces 12 4) Black Coals-17 large 7 triangular. 5) User/Installation Instructions 6) Guarantee Card 7) Fire front and Fret INSTALLATION INSTRUCTIONS 1) APPLIANCE DATA Gas Category (Natural gas)
  • Page 3: General Installation Requirements

    2 GENERAL INSTALLATION REQUIREMENTS 2.1 The law demands that all gas appliances are installed and serviced by a qualified installer in accordance with the current GAS SAFETY (INSTALLATION AND USE) REGULATIONS OR RULES IN FORCE. The installation must comply with these installation instructions and all relevant parts of Local and National Building Regulations issued by the Department of the Environment and Local and National Building Standards (Scotland Consolidation) Regulations issued by the Scottish...
  • Page 4 2.5 The Fireplace 1) The recess into which the 22" HOT BOX is to be fitted should conform to the dimensions shown in Fig.1 and must be constructed of non-combustible materials. If a chairbrick is already in position, this must be removed and the recess cleared to permit the provision of a debris-collection space (minimum depth of 50mm) behind the appliance.
  • Page 5: Installing The Appliance

    2.7 Care should be taken to ensure soft furnishings or decorations, such as wallpaper, are not too near the appliance, as they may become discoloured or scorched. 3) INSTALLING THE APPLIANCE 3.1. Check that the fire opening, flue and chimney comply with the relevant Building Regulations for England and Scotland.
  • Page 6 3.5 Isolate the gas supply by turning off at the meter. Fit a suitable means of isolation to the gas supply to the fire. 3.6 Establish the route the gas supply will take. NB only rigid or semi-rigid pipe is acceptable.
  • Page 7 4.4 Place the left and right hand side cheeks to sides of fire. NB Direction of cut angles at rear of cheek. 4.5 Insert the front coal blocks into the coal block support shelf.(SEE FIG 7) 4.6 Position 7 triangular coals to the rear top of the base boards. Ensure they are equally spaced (See Figs 8 and 9)
  • Page 8 4.7 Place 6 large coals along the front coal block support and resting on the ceramic burner inserts. (See Figs 8 and 9) Place 6 large coals on the rear edge of the front row of coals, resting on the triangular coals (see Figs 8 and 9) 4.9 Remove any protective film from the trim.
  • Page 9: Commissioning The Appliance

    LANDSCAPE 22 LOG LAYOUT 5) COMMISSIONING THE APPLIANCE Check all sequences of the controls: - 5.1 Ensure the main gas supply is turned on. 5.2 Turn on the gas at the isolating gas cock. 5.3 Press in and turn the main burner control...
  • Page 10: Turning Off The Appliance

    5.4 Keep the main burner control knob depressed for approx., 10 seconds then gently release it ensuring the pilot flame stays alight. 5.5 If the pilot flame extinguishes, repeat the process, depressing the control knob for a slightly longer period. 5.6 In the event of ignition failure the following method of lighting should be used: Press in and turn the main burner control anti-clockwise until the indicator is opposite PILOT/ IGN.
  • Page 11: Briefing The User

    8.4 After 5 minutes, light a smoke match and position it approximately 100mm down from the top of the fire opening and 30mm into the fire opening from the front edge (see Fig 12). Run the match across the full width of the fire opening. All smoke should be drawn into the flue.
  • Page 12: Servicing The Burner

    SERVICING THE BURNER 11.1 TO REMOVE THE BURNER ASSEMBLY FROM THE CASING, Disconnect the gas supply at the inlet elbow. 11.2 Unscrew the retaining screw:- a) Located centrally at the bottom of the control panel. b) The burner tray can now be removed together with the ceramic backboard. 11.3 Check the two burner slots for any debris.
  • Page 13 SPARE PARTS FOR 22" HOT BOX Description Part Nos ODS-pilot Assembly OP9039 OP9214 Control Valve (FSD) Type A V3-81 V3-85 Control Valve (FSD) Type B THER21512B THER21512A Control Knob K1-20 K1-20 Main Injector J1-23 J1-15 Matrix GENMAT GENMAT Fibre backboard GENBAC GENBAC Burner inserts (3)
  • Page 14: Section Two Users Instructions

    SECTION TWO USERS INSTRUCTIONS GENERAL INSTRUCTIONS AND INFORMATION a) The installation of this product must be carried out by a Qualified Installer and in accordance with the rules in force and requirements of the current GAS SAFETY (INSTALLATION AND USE) REGULATIONS or RULES IN FORCE and the installation instructions.
  • Page 15: Remote Control

    Keep main burner control knob depressed for approx., 10 seconds then gently release it ensuring the pilot flame stays alight. 1.5 If the pilot flame extinguishes, repeat the process, depressing the control knob slightly longer period. event ignition failure following method lighting should be used: Press in and turn the...
  • Page 16 To Switch Fire On Point the transmitter towards the fire. Press the two round buttons on the left of the transmitter, once, at the same time. A clicking sound will be heard and the pilot will establish. Once the pilot is lit the fire will automatically light on low.
  • Page 17 When using the remote control to operate the fire, ensure that the main gas control is set to the HIGH (large flame position) for maximum efficiency. To Switch Fire On. Point the handset towards the fire. Press the two buttons simultaneously, the fire should cross light smoothly.
  • Page 18 smoking, eating or drinking in the work area and always wash your hands before eating or drinking. The minimum clearance from the edge of the fire to a combustible surface at the side of the fire should be 150mm and if a shelf is installed above the fireplace it should be no closer 150mm to the top of the fire.
  • Page 19: Spare Parts List

    Place 6 large coals on the rear edge of the front row of coals, resting on the triangular coals (see Figs 8 and 9) SPARE PARTS LIST. PART NUMBERS Coal Pack A (17 large) COALLA Coal Pack B (7 triangular) COALTR User Manual MANULT...