Download Print this page
SciCan AquaStat W 10000 Use And Care Manual

SciCan AquaStat W 10000 Use And Care Manual

Water distiller

Advertisement

WATER DISTILLER
Use and Care Guide
Model / Series No. W 10000
DISTILLATEUR D'EAU
Guide d'utilisation
et d'entretien
Modèle / Numéro de série W 10000
WASSERDESTILLIERGERÄT
Bedienungsanleitung
Modell / Serienummer W 10000
DESTILADOR DE AGUA
Instrucciones de uso
Modelo / Número de serie W 10000
DISTILLATORE D'ACQUA
Istruzioni per l'uso
Modello / Numero di serie W 10000
L8588 Rev 1.0
www.scican.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the AquaStat W 10000 and is the answer not in the manual?

Questions and answers

Summary of Contents for SciCan AquaStat W 10000

  • Page 1 Modèle / Numéro de série W 10000 WASSERDESTILLIERGERÄT Bedienungsanleitung Modell / Serienummer W 10000 DESTILADOR DE AGUA Instrucciones de uso Modelo / Número de serie W 10000 DISTILLATORE D’ACQUA Istruzioni per l’uso Modello / Numero di serie W 10000 L8588 Rev 1.0 www.scican.com...
  • Page 2: Table Of Contents

    Superfici esterne........61 Guide de dépannage ........21 Guida per l’eliminazione dei guasti....63 Conditions de Garantie .........23 Garanzia e indirizzi dei Servizi Assistenza Clienti......66 Aquastat is a trademark of SciCan. INHALTSVERZEICHNIS For all service and repair inquiries: In Canada 1-800-870-7777 Einleitung ............1...
  • Page 3: Introduction

    Introduction our Aquastat distiller will provide you with a durable appliance capable of reducing the many impurities which can be found in tap water. Aquastat reduces these impurities through the process of evaporation and condensation. As the water is heated it turns into vapor which rises leaving most impurities behind in the boiling chamber or discharged through the volatile gas vent.
  • Page 4: Safety Precautions

    Safety Precautions Observe these safety precautions when using your water distiller. • Read all instructions before using. • Do not let the cord touch hot surfaces or hang over the edge of a counter or table. • Always allow the boiling chamber to cool before removing it from the distiller.
  • Page 5 Safety Precautions Continued Your distiller requires no special care other than cleaning. If servicing becomes necessary, please contact an authorized distributor. See the warranty on page 10 for service details. Do not attempt to repair the distiller yourself. The distiller is designed and intended for household use only. This system was tested in accordance with the WQA S-400 Series Standard and has the product water production rate of 1 US gallon (4 L) per 4 hours and has the product water storage capacity of 1 US gallon.
  • Page 6: Clean The Water Bottle

    Preparing Your Aquastat Cooling Vents Baffle Cord Securing Dispensing Valve Boiling Chamber Water Bottle Distiller Chassis To Clean the Water Bottle First, make sure the dispensing valve is installed and tightened onto the water bottle. Then fill the water bottle about full with water.
  • Page 7: Operating Instructions

    Operating Instructions Place the distiller on a dry, level surface in a well ventilated area. Plug the cord into a properly grounded rated voltage AC electrical outlet ONLY. Remove the boiling chamber from the distiller by grasping its handle and pulling it straight out of the distiller chassis. Do not lift up when pulling the boiling chamber out of the chassis.
  • Page 8: Boiling Chamber

    Operating Instructions Continued Slide the boiling chamber into the distiller chassis and press firmly to insure that it is properly placed. It is important that the boiling chamber be pressed firmly into the distiller chassis. Flat edge It is recommended that you place one Baffle of baffle hand on the back of the distiller chassis...
  • Page 9 Operating Instructions Continued 12. Place the water bottle on the base of the distiller chassis. The base of the distiller chassis has raised edges to assist in positioning the water bottle properly. NOTE: Do not remove the water bottle while the distiller is running. 13.
  • Page 10 Cleaning Instructions CAUTION: To prevent personal injury or electric shock, do not immerse the distiller, its boiling chamber, cord, or plug in water or other liquid. Boiling chamber Rinse the boiling chamber after every distillation cycle once the unit has cooled completely.
  • Page 11 Troubleshooting Guide Problem Possible cause Solution Start button does Distiller is not plugged in. Plug the distiller into a not light up. rated voltage outlet. Boiling chamber is not Make sure the boiling fully inserted. chamber is seated properly. Start button lights up, but The fan’s delayed start Wait at least 1 ⁄...
  • Page 12 Troubleshooting Guide Continued Problem Possible cause Solution The distiller is not in a Distiller must be well ventilated area. operated in a well ventilated area for proper heat dissipation. See page 4. There is excess scale Clean the boiling build-up in the boiling chamber.
  • Page 13 Limited Warranty This certifies that your product is warranted by the manufacturer to be free from defects in material, construction, and craftsmanship for 1 (one) full year from the date of original purchase. If service should be necessary, send the product with a description of the claimed defect to the distributor from whom the product was purchased.
  • Page 14 Limited Warranty SciCan, Division of Lux & SciCan Medtech AG, Zwingenberger Ltd. Alpenstrasse 16, CH-6300 Zug, Switzerland 1440 Don Mills Road, Toronto, ON M3B 3P9 Phone : 41-41-727-70-27 Phone : (416) 445-1600 Fax : 41-41-727-70-29 Fax : (416) 445-2727 Toll Free : 1-800-667-7733 SciCan, Inc.