Test 1 120V Ac Electrical Supply - LG DLGX8001 Service Manual

Electric & gas dryer
Hide thumbs Also See for DLGX8001:
Table of Contents

Advertisement

Test 1
120V AC Electrical supply
NOTE: To properly check power supply in case of floating neutral or
high resistance connections, a load must be applied to the
circuit. It is important that the power button be pressed while
checking the voltages as described below.
Tap Relay Connector
Black(X4)
Blue(X562)
BK
WH
BR
With the dryer plugged in, press the
POWER button to turn on dryer.
Check the voltage at the main PCB
between Black wire on the blue tab
BK
relay connector(X562) and White wire
on the black tab relay connector(X4)
Is 120VAC present while pressing the
start button?
(NOTE: For gas dryers skip this step.)
With the dryer plugged in, check the
voltage at the terminal block between the
neutral (WH) and L1 (BK) terminals. Is
the voltage 120 VAC while pressing the
START/PAUSE button?
With the dryer plugged in, check the
voltage at the power cord plug
between the neutral and L1 (and L2
for electric dryers). Is the voltage 120
VAC while pressing the
START/PAUSE button?
Replace the power cord.
YES
NO
YES
YES
33
•Replace
main PCB.
•Replace
YES
display
PCB.
power cord.
terminal
block
NO
connections.
power
supply fuse
or circuit
breaker.
NO
receptacle
connections.

Hide quick links: