0171942en 0907 Hydronic Air Heater Pureheat OPERATOR’S MANUAL...
Page 3
Ground Heaters, Inc. invoice date to Distributor or for a period of one year from Distributor’s invoice date to end-user, excluding pre-season orders which will have an effective warranty date of November 15th.
Page 6
(to properly adjust burner air intake and verify that proper combustion parameters have been achieved). licensed gas technician must supply all fuel lines, fittings, regulators, etc. necessary to connect the Pureheat NG/LP burner to the fuel source at the correct pressure and flow.
PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL TABLE OF CONTENTS Page Technical, Checklists, Warranty Information ..............Warnings ............................. ii, iii Specifications ..........................List of Abbreviations ........................ INTRODUCTION EXTERNAL FEATURES ....................INTERNAL COMPONENTS ....................1.2.1 Heater with Burner Options ..................1.2.2 Heater with Burner Detail ....................
Page 9
Using Five HHS3004 with Booster Pump for Curing and Frost Prevention Applications 2-7 MONITORING OPERATING PARAMETERS ..............UNIT SHUTDOWN......................2.7.1 Burner Shutdown ......................2.7.2 Disconnecting Hoses from Heat Xchangers™ and Pureheat ........2.7.3 Rewinding the Circulation Hose .................. 2.7.4 Completing Unit Shutdown ..................2-10 CONNECTING/DISCONNECTING OPTIONAL BOOSTER PUMP........
Page 10
PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL TABLE OF CONTENTS (continued) Page MAINTENANCE ADDING HEAT TRANSFER FLUID.................. 4.1.1 To Clear a “LOW LEVEL FAULT”................BURNER INSTALLATION/CHANGEOVER ..............4.2.1 From NG/LP to Diesel/Fuel Oil ..................4.2.1.1 Installation ......................4.2.1.2 Setup ........................4.2.2 From Diesel/Fuel Oil to NG/LP ...................
Page 12
PUREHEAT 45,000 SQ. FT FROST PREVENTION LAYOUT (FIVE HHS 3004'S AND FIVE 4-PORT MANIFOLDS)............B-8 PUREHEAT VALVE POSITIONS FOR ADDING HTF (MACHINE IN USE).........B-9 PUREHEAT VALVE POSITIONS FOR ADDING HTF (MACHINE NOT IN USE) ......B-10 PUREHEAT QUICK-CONNECT AND CAM-LOCK CARE AND MAINTENANCE.....B-11 APPENDIX C PUREHEAT APPLICATIONS AND CAPACITIES ...............
PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL LIST OF ABBREVIATIONS The following is a list of abbreviations used throughout the Operator’s Manual: Abbreviation/Symbol Term/Meaning amp. ampere (measurement of electrical current) above sea level British Thermal Unit (measurement of heat energy) °C...
The Pureheat™ Hydronic Air Heater is equipped with a 5-Port On-Board Manifold and 1,000 ft (396 m) of 1 in. (25 mm) ID Red Circulation Hose Assemblies with Quick-Connects (QCs). The standard equipment package includes the following lengths of Circulation Hoses: Two (2) 200 ft (61 m), Four (4) 100 ft.
PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 1 INTERNAL COMPONENTS (Photos 1-2 through 1-6) 1.2.1 Heater with Burner Options (Photo 1-2) The following components are accessed via the side door: 1. Main Control Panel 10. Main Pump 2. Hydronic Heater and Expansion Tank (not shown) 11. Rewind Foot Pedal 3.
Page 18
PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 1 1.2.2 Heater with Optional Burner Detail (Photos 1-3 and 1-4) The following components are accessed via the Side Door: 1. Natural Gas (NG)/Liquid Propane (LP) Supply NG/LP Gas Train Gas Connection NG/LP Burner Control (not shown) 2.
PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 1 1.2.3 Inside Rear Doors The following components are located inside the Rear Door: (Photo 1-5 through 1-8) 1. HX200 Heat Xchangers 2. Cab Interior Light and Remote Manifold Storage Location – not shown) 3.
PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 1 IDENTIFICATION The Pureheat™ Hydronic Air Heater serial number is located on the Main Control Panel. Always reference the Pureheat serial number when ordering parts or requesting technical assistance. SAFETY FEATURES Pureheat™ Hydronic Air Heaters are safe, quality equipment, are NHTSA compliant, meet all state requirements, meet all Transport Canada requirements, and are CSA certified.
3. Self Respect: Dresses for the weather; wears eye protection and gloves; and does not take chances with personal safety. Do not operate the Pureheat while intoxicated or impaired by alcohol or other substances. 4. Careful and Responsible: Insures the machine is operating properly before leaving it unattended;...
13. Torque for wheel lug nuts should be set at 110 ft-lbs. Failure to observe these warnings may result in injury or death. REPAIR PARTS AND ACCESSORIES Your Ground Heaters Distributor carries a complete line of parts and accessories needed for all repair or replacement requirements. MAINTENANCE All maintenance should be performed by a qualified service technician using the Operators Manual.
100 ft (30 m) or 200 ft (61 m)] of Circulation Hoses. Maximum run should not exceed 200 ft (61 m) from base unit. • The maximum vertical rise or drop from the Pureheat to each HX200 is 60 ft (18 m) one way from base unit. 2.1.1.2 HX200 Heat Xchangers™ with Optional Booster Pump A Pureheat™...
2.1.2 Optional Booster Pump All Pureheat™ Hydronic Air Heaters are equipped to accept an optional Booster Pump which requires the use of an Auxiliary Pump Panel for electrical connection to provide safety shutdown of the optional Booster Pump. (For setup instructions, refer to Section 2.8, CONNECTING/DISCONNECTING OPTIONAL BOOSTER PUMP.)
2.2.1 Positioning 1. Position the Pureheat’s 5-Port On-Board Manifold as close as possible to the space to be heated. Circulation Hoses can then easily enter and exit the structure. The Pureheat must be positioned a minimum of 12 ft (3.6 m) from fuel source or combustible materials.
PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 2 2.2.3 Unloading HX100 Heat Xchangers 1. OPEN the Rear Doors and remove the aluminum Ramp from the storage location above Xchangers. 2. Position the Ramp onto the Ramp Alignment Pins to unload either the left side, right side or the middle section HX100s.
2.2.7 Deployment of Circulation Hoses or Option Heat Transfer Hose (Applies to Pureheat and Hose Handling Systems HHS3004) The Hose Reel contains Ten (10) 1 in. ID Red Circulation Hoses with QCs [Four (4) at 50 ft (15 m), Four (4) at 100 ft (30 m), and Two (2) at 200 ft (61 m)].
PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 2 2.4.2 Warming the Heat Transfer Fluid 1. Use the UP/DOWN arrow keys to adjust the temperature set-point on the TC to 70°F (21°C). (Refer to Appendixes A-2 and A-3.) 2. Turn the BURNER Switch ON, then verify the following: a.
PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL–SECTION 2 OPERATING WITH OPTIONAL ACCESSORIES The Pureheat has the capability to operate with up to Twenty (20) 750 ft (228 m) Accessory Hose Loops using One (1) Booster Pump, Five (5) Hose Handling Systems 3004 (HHS3004), Five (5) 4-Port Remote Manifolds and One (1) Auxiliary Pump Panel.
PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 2 2. Place the Five (5) HHS3004 and Five (5) 4-Port Remote Manifolds spaced appropriately on the jobsite for thawing application. 3. Connect the five (5) 4-Port Remote Manifolds to the 5-Port On-Board Manifold as directed in Step 2.2.7, Deployment of Circulation Hoses.
2. Turn ON the HOSE REWIND Switch. 3. Rinse QC in a bucket of water to remove any dirt before connecting onto hose reel. (Refer to Appendix B-11 PUREHEAT SAFTEY CONTROLS 2-10 QUICK CONNECT AND CAM-LOCK CARE AND MAINTENANCE.
PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 2 9. Return Foot Pedal to storage location. 2.7.4 Completing Unit Shutdown 1. Retrieve and reload the Heat Xchangers™ into the trailer. Stow ramp, latch and lock the Rear Doors to secure Heat Xchangers™.
Pureheat) to the Auxiliary Pump Panel. NOTE: The Booster Pump should only be started after the Pureheat has been set up and is ready for use. The Booster Pump will only operate when the Main PUMP Switch is turned ON at the Main Control Panel.
PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 3 BURNER ADJUSTMENT AND SHUTDOWN The Pureheat™ Hydronic Air Heater can be operated on natural gas (NG), liquid propane vapor (LP) or diesel/fuel oil (OIL). (Refer to Appendix A-24 or A-25 for Burner component identification) NOTE: All Burners on Pureheat™...
PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 3 3.1.1.1 Fuel Pressure Adjustment 1. Ensure that the fuel supply source is OFF. 2. Ensure that the Main Gas Supply Ball Valve is SHUT. 3. Remove the ¼ in. pressure tap plug located in the gas train inlet ball valve body (opposite of the pilot gas cock).
3. Shut the Main Gas Supply Ball Valve. Remove the manometers, petcocks and adapters, and reinstall pipe plugs (use pipe dope). NOTE: Should the Burner fail to respond during any of the air adjustments or if the fuel pressure cannot be adjusted or drifts, discontinue Burner setup and contact your Pureheat™ Distributor. DIESEL/FUEL OIL 3.2.1...
PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 3 Use air band and shutter settings and fuel pressure adjustments to obtain an Exhaust O value of 3 to 4% in the 3 to 4% range assures that there are no and a smoke spot value of 1 or less.
PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 3 6. Once the Burner lights, sample the exhaust. Adjust the air band and shutter until combustion parameters fall within the above outlined values. 7. Lock the air band and shutter in place by tightening the locking screws.
12. Cover the open end of the fill hose to retain HTF after priming. NOTE: If the HTF container height is such that it will not allow gravity flow from the Pureheat™ fill hose, use a separate container with an opening low enough to facilitate priming the fill hose using the method described.
PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 4 17. After the Low Level Shutdown device has cycled through a 15 second self test, the low level condition will clear. 18. The PUMP Switch may now be turned ON, and the HTF FILL Switch released to finish filling.
1. Set the Burner Air Band at 6 and Air Shutter at 6. These initial air settings will be fine tuned later. 2. With fuel in the remote tank, power up the Pureheat™ control panel as directed in Section 2.4, START UP.
PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 4 4.2.2.1 Installation (Refer to Appendix A-24) 1. Remove the trailer enclosure lower panel located below the trailer's left side door adjacent to the fender (to provide unrestricted access to the Burner mounting plate on the Pureheat™...
LISTED BELOW SHOULD BE PERFORMED BY CERTIFIED PERSONNEL AT YOUR GROUND HEATERS DISTRIBUTOR. 2. When operating the Pureheat™ at high altitudes, the hydronic heater should be checked every 500 hours for sooting or other combustion abnormalities. Combustion Analyzer and Smoke Spot Tester must be used for this test.
PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 4 SUMMER STORAGE INSTRUCTIONS 1. Allow the heater to cool sufficiently. Cover the chimney and the Burner with plastic wrap or other waterproof material. This will prevent corrosive moisture build-up and blockages caused by animal nests.
PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 5 TRANSPORTING THE PUREHEAT HYDRONIC AIR HEATER This section describes the three basic methods of Pureheat Hydronic Air Heater transport and associated precautions. TOWING The Pureheat is easily towed by a vehicle rated to tow up to 8,500 lbs (3,855 kg) (HX Package) or 11,300 lbs (5125 kg) for the fuel tank package.
TROUBLESHOOTING CHART (Contact your local Ground Heaters Distributor for situations not covered in this section.) NOTE: Discontinue troubleshooting activities and shut down the Pureheat™ Hydronic Air Heater if one of the following occurs: 1. One of the GFIs trips and will not remain reset.
BURNER switch OFF. Turn the pump switch ON and the pump will start immediately. Turn the PUMP switch OFF. If the test does not conform to the instructions and results as outlined above, call your Ground Heaters distributor. 6- 3 V.
PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 6 BURNER CONTROL LOCKOUT (Refer to Appendix A-13 or A-8 through A-14) 6.3.1 Gas Burner Control The POWER light will illuminate only during the heating cycle. After flame is established, the POWER, PILOT, MAIN and FLAME lights should all be illuminated.
PUREHEAT CONTROL PANEL EXTERIOR LAYOUT MAIN MAIN BREAKER 1 BREAKER 2 HOURS LINE1GFI LINE 2 GFI FUJI ELECTRIC C1 C2 WARNING REFER TO OPERATOR MANUAL TO CLEAR FAULTS PXR-4 BURNER LOW LEVEL FAULT FAULT TEMPERATURE CONTROL HTF FILL PUMP BURNER...
PUREHEAT CONTROL PANEL DOOR INTERIOR LAYOUT HTF FILL PUMP BURNER HOSE REWIND CAB LIGHT WIRE NUMBERS SHOWN IN BOLD TEMPERATURE CONTROL BURNER LOW LEVEL FAULT LIGHT FAULT LIGHT MAIN MAIN LINE 1 GFI LINE 2 GFI BREAKER 1 BREAKER 2...
Page 56
PUREHEAT MAIN CONTROL PANEL EXTERIOR COMPONENT FUNCTION AND IDENTIFICATION DOOR COMPONENTS BREAKER 1 CURVE 10 15 AMP. (P/N E100-354): Provides ON and OFF power control and circuit protection for electrical circuit one. BREAKER 2 CURVE 10 20 AMP. (P/N E100-123): Provides ON and OFF power control and circuit protection for electrical circuit two.
PUREHEAT MAIN CONTROL PANEL INTERIOR COMPONENT FUNCTION AND IDENTIFICATION PANEL INTERIOR COMPONENTS CR-1 RELAY (P/N E100-205): Relay CR-1 is controlled by the Low Level Shutdown Device contacts C - B (NO) (normally open). Relay CR-1 contacts 8 – 7 (N.C.) (normally closed) control the 120V power to the LOW LEVEL FAULT light.
PUREHEAT DIESEL BURNER CONTROL SEQUENCE OF OPERATION AND LOCKOUT NORMAL SEQUENCE OF OPERATION: Assuming a normal power up has been completed per Section 2 of this manual, the BURNER Switch is turned ON, the In-Line Fuel Heater is energized and begins to warm the fuel in the Nozzle Assembly Tube. With a demand for heat, output contacts 14 &...
PUREHEAT CIRCULATION - BOOSTER PUMP MOTOR WIRING WIRE COLORS = BLACK RED = RED WHT = WHITE GRN = GREEN = BLUE = YELLOW = WHITE W/ YELLOW TRACE WHITE WITH YELLOW TRACE (X2) PUMP CABLE CIRCULATION - BOOSTER PUMP ASSY.
PUREHEAT TRAILER JUNCTION BOX AND BATTERY WIRING 7-WAY PLUG WIRING COLORS TRAILER WIRE COLORS BATTERY WIRE COLORS BLK = BLACK - VEHICLE 12 VOLTS DC BLK = BLACK - NOT USED BLK = BLACK - VEHICLE 12 VOLTS DC RED = RED...
PUREHEAT NG/LP BURNER COMPONENT IDENTIFICATION (P/N P100-673) HONEYWELL POWER PILOT FLAME MAIN ALARM RESET REGULATOR DUST CAP BURNER BLOWER WHEEL (P/N P100-334) MANIFOLD GAS PRESSURE REGULATOR (P/N P100-342) MANIFOLD GAS SHUT-OFF VALVE MAIN GAS VALVE (P/N P100-340) AIR DAMPERS AUX GAS VALVE (P/N P100-341) GAS TRAIN UNION 1/16"...
BOOSTER PUMP TO PUREHEAT CONNECTING SUPPLY MANIFOLD ENSURE VALVES 5,6 AND 7 ARE SHUT. REMOVE THE CAPS AND PLUGS FROM THE PUREHEAT BOOSTER PUMP CONNECTION POINTS AND THE BOOSTER PUMP HOSE ENDS. SHUT SHUT SHUT HTF SUPPLY - FLOW DIRECTION...
HX200 HEAT XCHANGER TO PUREHEAT CONNECTION LAYOUT ™ FILL HOSE DUST CAP FILL HOSE OPEN OPEN RETURN MANIFOLD SUPPLY MANIFOLD SHUT MAIN PUMP PRESSURE GAUGE CHECK VALVE SHUT HTF SUPPLY - FLOW DIRECTION HTF RETURN - FLOW DIRECTION OPEN SHUT...
HX100 HEAT XCHANGER TO PUREHEAT CONNECTION LAYOUT ™ FILL HOSE DUST CAP FILL HOSE OPEN OPEN RETURN MANIFOLD SUPPLY MANIFOLD SHUT MAIN PUMP PRESSURE GAUGE CHECK VALVE SHUT HTF SUPPLY - FLOW DIRECTION HTF RETURN - FLOW DIRECTION OPEN SHUT...
HX50 HEAT XCHANGER TO PUREHEAT CONNECTION LAYOUT FILL HOSE DUST CAP FILL HOSE OPEN OPEN RETURN MANIFOLD SUPPLY MANIFOLD SHUT MAIN PUMP PRESSURE GAUGE CHECK VALVE SHUT HTF SUPPLY - FLOW DIRECTION HTF RETURN - FLOW DIRECTION OPEN SHUT FOUR PORT...
PUREHEAT 18,000 SQ. FT THAW LAYOUT (THREE HHS 3004'S AND THREE 4-PORT MANIFOLDS) FILL HOSE DUST CAP FILL HOSE OPEN OPEN RETURN MANIFOLD SUPPLY MANIFOLD SHUT MAIN PUMP PRESSURE GAUGE CHECK VALVE OPEN HTF SUPPLY - FLOW DIRECTION HTF RETURN - FLOW DIRECTION...
PUREHEAT 30,000 SQ. FT CURE LAYOUT (FIVE HHS 3004'S AND FIVE 4-PORT MANIFOLDS) FILL HOSE DUST CAP FILL HOSE OPEN OPEN RETURN MANIFOLD SUPPLY MANIFOLD SHUT MAIN PUMP PRESSURE GAUGE CHECK VALVE OPEN HTF SUPPLY - FLOW DIRECTION HTF RETURN - FLOW DIRECTION...
PUREHEAT 45,000 SQ. FT FROST PREVENTION LAYOUT (FIVE HHS 3004'S AND FIVE 4-PORT MANIFOLDS) FILL HOSE DUST CAP HTF SUPPLY - FLOW DIRECTION OPEN SUCTION VALVE FILL HOSE HTF RETURN - FLOW DIRECTION OPEN HTF FILL SHUT VALVE RETURN MANIFOLD...
Page 90
OPEN SHUT 1. Power up the PureHeat as described in section 2 of this manual. 2. Place the container of HTF near the access doors for the Hose Reel and the Main Control Panel. 3. Remove the Fill Hose from its storage location below the hose reel.
SHUT 1. Power up the PureHeat as described in section 2 of this manual. 2. Attach a hose equipped with Quick-Connect fittings to the Supply and Return Manifold in order to provide a complete fluid path prior to adding HTF.
PUREHEAT QUICK-CONNECT AND CAM-LOCK CARE AND MAINTENANCE NEVER: ALWAYS: Drop onto a hard surface such as concrete. Keep connection devices free of sand and dirt. Drive over with any size vehicle. Rinse in clear water before and after each use.
PUREHEAT APPLICATIONS AND CAPACITIES (See Appendix pages B-1 – B-10 for accessories connecting) PUREHEAT, FIVE HX200 or, EIGHT HX100 or, TWENTY HX50 HEAT XCHANGERS™ THAWING HX200 HX100 HX50 CURING FROST PREVENTION AIR HEATING Up to: 1,200.00 ft (with Propane Fuel @ .6 BTU per ft...
Page 96
Wacker Construction Equipment AG · Preußenstraße 41 · D-80809 München · Tel.: +49-(0)89-3 54 02 - 0 · Fax: +49 - (0)89-3 54 02-3 90 Wacker Neuson Corporation · P.O. Box 9007 · Menomonee Falls, WI 53052-9007 · Tel. : (262) 255-0500 · Fax: (262) 255-0550 · Tel. : (800) 770-0957 Wacker Asia Pacific Operations ·...