Nordyne O4HD-091A-14-FA-DV Installation, Operation And Maintenance Manual page 10

Oil fired warm air furnaces
Table of Contents

Advertisement

temperature h asdropped andthe limitcontrol h asreset,
thefanwilloperate untilthefanofftimeis achieved. The
oil burnerwill thenresumeoperation andcontinue until
thethermostat is satisfied. R estore thethermostat setting
toa comfortable temperature.
NOTE:
IF THE FURNACE
IS TO BE SHUT DOWN
FOR AN EXTENDED
PERIOD
OF TIME, CLOSE
THE OIL SUPPLY
VALVE
TO THE BURNER.
I'ACAUTION
I
DO NOT ATTEMPT
TO
START
THE
BURNER
WHEN
EXCESS
OIL HAS ACCUMULATED,
WHEN THE FURNACE
IS FULL OF VAPOUR,
OR
WHEN
THE
COMBUSTION
CHAMBER
IS VERY
HOT.
NEVER
BURN GARBAGE
OR PAPER
IN
THE FURNACE,
AND NEVER
LEAVE PAPER
OR
RAGS AROUND
THE UNIT.
22.
ECM BLOWER
MOTOR
OPERATION
(O4HD-091A-V-FA)
Setting Blower "ON" and "OFF" Timings
Blower
on/off time
delays are handled
by ECM
motor programming.
Features of this ECM variable
speed motor are that it will deliver a constant airflow
within a wide range of external static pressures, and
also includes:
Soft Start:
This ECM variable
speed
motor will
slowly ramp up to the required operating
speed.
This feature in the heating cycle allows the heat
exchanger
to reach operating
temperature
before
the set heat speed, which
minimizes
noise
and
increases comfort.
Soft Stop: At the end of the heating cycle, the ECM
variable speed motor will slowly ramp down.
This
feature allows for increased energy efficiency
and
reduced noise levels.
Dehumidification:
A dehumidification
feature has
been programmed into the variable speed motor. At
the start of each cooling cycle, the variable speed
motor will run at 82% of the rated airflow for 7.5
minutes.
After 7.5 minutes has elapsed, the motor
will increase
to 100% of the rated airflow.
This
profile
is used
to
provide
dehumidification
and
improve system efficiency.
Continuous
Fan Operation
: When the thermostat
continuous
fan (G) switch is on without
a call for
heating or cooling, the indoor fan is immediately
energized
up to 50% of the cooling speed.
This
feature allows continuous
circulation of air between
calls for heating or cooling.
If a call for heat (W) or cool (Y) occurs
during
continuous fan, the blower will remain energized
10