BLOCK SALT SOFTENER
INSTALLATION INSTRUCTIONS
Plumbing Regulations
This water softener should be installed in accordance
with
the
plumbing
available from your water softener dealer. Ask for.
Water pressure
The recommended operating pressure is between
1.5 and 6 bar (20 and 90psi), but the pressure should
not be below 1 bar (15psi) when water is flowing, or
exceed 8 bar (120psi). To check the water pressure you
need to connect a pressure gauge to the garden tap,
kitchen tap, or any other tap connected directly to the
Bypass valve
(normally closed)
Hard water
tee to outside
taps and hard
water taps
The diagram above shows how easy it is to install the Block Salt water softener.
regulations.
Copies
PLUMBING
Inlet valve
(normally open)
Check valve or
non-return valve
incorporating
backflow
prevention
to BS6282
Terminate at exterior
of the building as a
warning pipe
Rising main
stopcock
There are just four connections: mains water inlet, outlet, drain and overflow.
WRAS Information for Installation of Ion exchange
Water Softeners for Systems Supplying Water
are
for Domestic Purposes. June 2007 No 9-07-01.
mains water supply. Alternatively you may contact
the local water supplier who will tell you the water
pressure in your area. If the water pressure is above
6 bar we recommend installing a pressure limiting
valve which is available from your softener supplier.
Outlet valve
(normally open)
Drain connection
(connect drain to air gap)
Waste Pipe
Outlet
Inlet
Drain
Overflow
connection