CONTENTS ............ General presentation of the wall hung gas boiler General description of the wall hung gas boiler ............Description of the boilers types .................. Symbols ........................Pg 4 General instructions concerning the safety of the wall hung gas boiler ......Pg 5 Technical characteristics ...................
TYPE [kcal/h] The fan The pump production expansion vessel OPTIMUS MT 20670 C15 SPV 24 MEFM SYMBOLS S- with instant production of DHW (without cumulation) P- with pump V-with closed expansion vessel 24-the maximum power output in kW M- the burner is supplied by a continuous modulating valve...
C 15 SPV 24 MEFM RESET MOD GENERAL INSTRUCTIONS CONCERNING THE BOILER SAFETY This manual is part of the product and it has to be given to the user. Read this manual carefully and keep it carefully for a further application by the user and by the mounting and installing authorized personnel.
Domestic cold water pressure 0,2 - 8 bar Exhaust gases temperature at rated output 142,4°C Burned gases connection ( input- output) O 100 / O 60 Burned gases connection length Max 3 m Orientative values 150 l Maximum water content in the installation Maximum surface of the precinct 150 m²...
The fan The boiler is provided with a fan for scavenging. The flue system and the air supply (for the boiler with forced draft) is made of two concentric pipes connected to the outside of the room where the boiler is mounted. The exhaust gases/ water heat exchanger is monothermal, the domestic water is The exhaust gases/ water heat exchanger...
The command and control system of the boiler running performs: - the ignition and the protection when the flame is extinguished, provided by the electronic ignition; - the protection when the gas is switched off, provided by electro-valve; - the water pressure signalling in the boiler, provided by minimum pressure sensor; - the temperature signalling on the heating and DHW circuits, provided by the electronic board functions;...
For designing the central heating installation we must be aware of the hydraulic features of the pump. The hydraulic characteristic of the pump the third stage of the speed the second stage of the speed the first stage of the speed Pump output Q[mc/h]...
MOUNTING-INSTALLATION INSTRUCTIONS The chapter addresses both to the qualified persons which contribute to the boiler installation and to the beneficiary which is concerned that the effected works to be done following the safety rules in operation of all the installations which contribute to the good running of the boiler.
MOUNTING-INSTALLATION INSTRUCTIONS You must not use the boiler empty or only partly filled with water. THE USE OF EMPTY OR PARTLY FILLED BOILER MAY LEADS TO EXPLOSION. The domestic cold water supply pipe of the DHW processing circuit remains permanently open (the closing of the net is made only by the valves from the discharge points) to allow the dilatation taking over from this circuit.
It`s forbbiden to install the boiler without earthing. THE COUPLING FOR SCAVENGING Without coupling to the chimney The scavenging is made through a pipe of 60 mm diameter, coaxial with the air inlet pipe of 100 mm diameter. The exhaust pipe is within the inlet one. The input-output coaxial flue system is delivered with the boiler.
The control board DISPLAY SW 5 Fig 1. The control board for OPTIMUS MT Display board LCD in the user module Button - Operation function This button shuts down/ opens out the boiler (the boiler is still connected to the On/Off: tension).
Page 14
Comfort: pressing this button, you select the comfort module(symbol 6 on) and the SW 4 set range of the domestic circuit may decrease. Press again to cancel it (symbol 6 off). Heating: Pressing the button once, the temperature preset by the heating is displayed;...
DHW module in case of monothermal boilers (symbol 7 on) Ignition demand in the DHW module takes priority of the heating module. The burner ignition takes place when a DHW demand appears; the boiler tries to supply hot water to the user at a preset temperature.
- insufficient pressure of the water in the hydraulic core circuit (irregularity) in case the pressure sensor measures an insufficient pressure of the water in the system, (<0,5 bar) the burner and the pump are deactivated and the flickering intermittent symbol Err E1 occurs on the display.
THE BOILER RUNNING The boiler running will be < without permanent control> provided automatically by the controllers installed on the boiler, and eventually by the environment devices (room thermostat). These devices must be set at the temperature corresponding to the controlled environment. the temperature setting on the heating circuit will be between 40-80º...
Additional facilities you may obtain: - Mounting an exterior temperature sensor, the boiler adjusts the heat carrier temperature depending on the temperature value from outside the building, the room wanted temperature and the heat leakage coefficient through the building walls. T.
Delivering to the user It is compulsory that the qualified personnel to instruct the user in great detail about the following aspects on boiler starting: The boiler starting and the shutting-down procedures, in safety conditions by checking the following elements: * the electric power supply respecting the polarity * gas supply * the central heating circuit supply and loading...
STAMPING, DOCUMENTS, PACKING, STORAGE, QUALITY AND GUARANTEE CONDITIONS STAMPING A designated card is fixed on each product by sticking with following: The manufacturer company The name of the product The serial number and the lot Number of CE type examination certificate Quality Department authority sign The boiler type and size The gas type which the input rated pressure has been set for...
RESPONSIBILITIES DURING THE WARRANTY PERIOD MAXOPTIMUS Boiler C 15 SPV 24 MEFM MALFUNCTIONS WHICH REFER TO THE MANUFACTURER’S RESPONSABILITY Possible The component Repair mode Irregularities error signal Crt.. A defective running Replace the The minimum pressure sensor pressure sensor Interrupted course or Renew the course Temperature defective sensors...
MALFUNCTIONS WHICH REFER TO THE RESPONSABILITY OF THE UTILITIES PROVIDER The component Possible Repair The disturbed Causes error signal system mode Crt.. The boiler doesn`t - electrical power supply Call the run, there is no deficiency (inadequate Electrical electric signal on display electrical circuit, circuit power...
LISTS AND PLANS NECESSARY FOR MOUNTING AND PUTTING INTO SERVICE Plan 1 The couplings arrangement of Wall hung gas boiler with forced draft MAXOPTIMUS C15SPV24MEFM THE Coupling DIMENSION 1. DHW inlet ” outside thread 1/2 - 2. DHW outlet ” outside thread 3.
Plan 2 Hydraulic diagram of The Wall hung gas boiler with forced draft OPTIMUS - C15SPV24 MEFM 1.Electrical fan with Hall sensor 13. temperature sensing probe for DHW 2.main heat exchanger 14. minimum water pressure switch 3.secondary heat exchanger 15. safety thermostat 4.ignition/ionization electrode 16.
Plan 3 The Couplings diagram for the wall hung gas boiler with forced draft OPTIMUS MT- C15 SPV 24 MEFM Panta 3% (aprox. 2 ) 3/4” 3/4” 3/4” 1/2” 1/2”...
Plan 4 Typical flue system applications for the wall hung gas boiler with forced draft C15SPV24MEFM Lmin=1m; Lmax=3m COAXIAL FLUE Lmin=1m; Lmax=5m Lmin=1m; Lmax=5m TWIN FLUE...
Plan 5 Electrical diagram for the wall hung gas boiler C15SPV24MEFM 3 - WAY VALVE 10 11 TR 2 TO J3 (TO J9 IF MONOELECTRODE) EARTH EARTH FLAME ELECTRODE EARTH ROOM THERMOSTAT GAS VALVE LOCAL USER MANUAL HALL SENSOR INTERFACE SAFETY THERMOSTAT 961 INTERFACE 52 51 50 49 48 47 46 45 44...