Table of Contents

Advertisement

Quick Links

Our company network supports you worldwide with offices in Germany, Austria,
Switzerland, Great Britain and the USA. For more information please contact:
FORTEC Elektronik AG
Hauptniederlassung
Lechwiesenstr. 9
86899 Landsberg am Lech
Telefon:
+49 (0) 8191 91172-0
Telefax:
+49 (0) 8191 21770
E-Mail:
sales@fortecag.de
Internet:
www.fortecag.de
FORTEC Elektronik AG
Büro Wien
Nuschinggasse 12
A-1230 Wien
Telefon:
+43 1 8673492-0
Telefax:
+43 1 8673492-26
E-Mail:
office@fortec.at
Internet:
www.fortec.at
The information contained in this document has been carefully researched and is, to the best
of our knowledge, accurate. However, we assume no liability for any product failures or
damages, immediate or consequential, resulting from the use of the information provided
herein. Our products are not intended for use in systems in which failures of product could
result in personal injury. All trademarks mentioned herein are property of their respective
owners. All specifications are subject to change without notice.
Manual
SOM-6867
Advantech
FORTEC Elektronik AG
Büro West
Hohenstaufenring 55
50674 Köln
Telefon:
Telefax:
E-Mail:
Internet:
ALTRAC AG
(Tochter der FORTEC):
Bahnhofstraße 3
CH-5436 Würenlos
Telefon:
Telefax:
E-Mail:
Internet:
+49 (0) 221 272 273-0
+49 (0) 221 272 273-10
west@fortecag.de
www.fortecag.de
+41 (0) 44 7446111
+41 (0) 44 7446161
info@altrac.ch
www.altrac.ch

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SOM-6867 and is the answer not in the manual?

Questions and answers

Summary of Contents for Fortec Elektronik SOM-6867

  • Page 1 Manual SOM-6867 Advantech Our company network supports you worldwide with offices in Germany, Austria, Switzerland, Great Britain and the USA. For more information please contact: FORTEC Elektronik AG FORTEC Elektronik AG Hauptniederlassung Büro West Lechwiesenstr. 9 Hohenstaufenring 55 86899 Landsberg am Lech 50674 Köln...
  • Page 2 User Manual SOM-6867...
  • Page 3 A product returned without proof of the purchase date is not eligible for warranty service. Write the RMA number visibly on the outside of the package and ship it prepaid to your dealer. Part No. 2006686700 Edition 1 Printed in Taiwan March 2015 SOM-6867 User Manual...
  • Page 4: Declaration Of Conformity

    Product name and serial number – Description of your peripheral attachments – Description of your software (operating system, version, application software, etc.) – A complete description of the problem – The exact wording of any error messages SOM-6867 User Manual...
  • Page 5 Before setting up the system, check that the items listed below are included and in good condition. If any item does not accord with the table, please contact your dealer immediately.  SOM-6867 CPU module  1 x Heat spreader (1960065753N001) SOM-6867 User Manual...
  • Page 6: Safety Instructions

    The sound pressure level at the operator's position according to IEC 704-1:1982 is no more than 70 dB (A). DISCLAIMER: This set of instructions is given according to IEC 704-1. Advantech disclaims all responsibility for the accuracy of any statements contained herein. SOM-6867 User Manual...
  • Page 7 Don't touch any components on the CPU card or other cards while the PC is on.  Disconnect power before making any configuration changes. The sudden rush of power as you connect a jumper or install a card may damage sensitive elec- tronic components. SOM-6867 User Manual...
  • Page 8: Table Of Contents

    Figure 3.11iManager Configuration ..........22 Figure 3.12Serial Port 2 Configuration ........23 Figure 3.13Serial Port 3 Configuration ........24 Figure 3.14Hardware Monitor ............. 25 3.3.6 Serial Port Console Redirection..........26 Figure 3.15Serial Port Console Redirection ....... 26 SOM-6867 User Manual...
  • Page 9 S/W Introduction & Installation..51 S/W Introduction ..................52 Driver Installation ..................52 4.2.1 Windows Driver Setup ..............52 4.2.2 Other OS..................52 Advantech iManager ................52 Appendix A Assignment......... 55 SOM-6867 Type 6 Pin Assignment............56 SOM-6867 User Manual viii...
  • Page 10 Table D.1: System I/O ports............66 DMA Channel Assignments ..............67 Table D.2: DMA channel assignments........67 Interrupt Assignments ................67 Table D.3: Interrupt assignments ..........67 1st MB Memory Map ................68 Table D.4: 1st MB Memory Map ..........68 SOM-6867 User Manual...
  • Page 11 SOM-6867 User Manual...
  • Page 12: Chapter 1 General Information

    Chapter General Information This chapter gives background information on the SOM-6867 CPU Computer on Module Sections include:  Introduction  Specification  Functional Block Diagram...
  • Page 13: Introduction

    SOM-6867 provides a variety of interfaces such as PCI Express, SATA Gen 2 USB3.0, USB client, and advanced optional functions for on-board storage. Moreover, PCIe x4 can be used as x4 or x1 - making SOM-6867 more flexible. Advantech iManager 2.0 satisfies a lot of embedded application requirements with...
  • Page 14: Expansion Interface

    ATX: +8.5~20V and +4.75~5.25VSB (standby power) AT: +8.5~20V CMOS Battery: +3.3V  Temperature Specification: Operating: 0 ~ 60°C (32 ~ 140°F) Storage: -40 ~ 85°C (-40 ~ 185°F)  Humidity Specification: Operating: 40°C@95% relative humidity, non-condensing Storage: 60°C@95%relative humidity, non-condensing SOM-6867 User Manual...
  • Page 15: Functional Block Diagram

    (Intel I210) USB3.0 USB3.0-to-LAN (option) DDI 2 HDMI / DisplayPort / DVI LPC BUS (Option BOM with LVDS) WDT / GPIO / I iManager RS1/ RS2/ FAN SMBus SPI Bus SPI BIOS Figure 1.1 Functional Block Diagram SOM-6867 User Manual...
  • Page 16: Chapter 2 Mechanical Information

    Chapter Mechanical Information This chapter gives mechanical information on the SOM-6867 CPU Computer on Module Sections include:  Board Information  Mechanical Drawing  Assembly Drawing...
  • Page 17: Board Information

    Board Information The figures below indicate the main chips on SOM-6867 Computer-on-Module. Please aware on these positions while designing your carrier board to avoid mechan- ical and thermal issues for best performance. DDR3L SODIMM OnModule Smart Fan Connector BIOS Socket Processor Figure 2.1 Board Chips Identify - Front...
  • Page 18: Connector List

    Description Wafer 2.0, 3P 90D(M)DIP 2001-WR-03-LF W/Lock Pin Name Fan Tacho-Input Fan Out Mechanical Drawing For more detail about 2D/3D models, please find on Advantech COM support service website http://com.advantech.com. Figure 2.3 Board Mechanical Drawing - Front SOM-6867 User Manual...
  • Page 19: Figure 2.4 Board Mechanical Drawing - Back

    Figure 2.4 Board Mechanical Drawing - Back Figure 2.5 Board Mechanical Drawing - Back SOM-6867 User Manual...
  • Page 20: Assembly Drawing

    These figures demonstrate the assembly order from thermal module, COM module to carrier board. M2.5 Screw Stand off + Nut Figure 2.6 Assembly Drawing There are 4 reserved screw holes for SOM-6867 to be pre-assembled with heat spreader. SOM-6867 User Manual...
  • Page 21 SOM-6867 User Manual...
  • Page 22: Chapter 3 Bios

    Chapter BIOS This chapter gives BIOS setup information for the SOM-6867 Computer on Module board Sections include:  Introduction  Entering Setup  Hot / Operation Key  Exit BIOS Setup Utility  EnableUSB 3.0  BIOS/FW Supported Matrix...
  • Page 23: Entering Setup

    Entering Setup SOM-6867 BIOS has been stored into a flash ROM which is soldered on board. With the BIOS Setup program, users can modify BIOS settings and control various system features. This chapter describes the basic navigation of the SOM-6867 BIOS setup screens.
  • Page 24: Main Setup

    Use this option to change the system time and date. Highlight System Time or System Date using the <Arrow> keys. Enter new values through the keyboard. Press the <Tab> key or the <Arrow> keys to move between fields. – System Date: mm/dd/yyyy – System Time: hh/mm/ss SOM-6867 User Manual...
  • Page 25: Advanced Bios Features Setup

    Advanced BIOS Features Setup Select the Advanced tab from the SOM-6867 setup screen to enter the Advanced BIOS Setup screen. Users can select any item in the left frame of the screen, such as CPU Configuration, to go to the sub menu for that item. Users can display an Advanced BIOS Setup option by highlighting it using the <Arrow>...
  • Page 26: Trusted Computing

    3.3.1 Trusted Computing Figure 3.4 Trusted Computing Settings  Security Device Support This item allows users to enable or disable BIOS support for security device. SOM-6867 User Manual...
  • Page 27: Acpi Settings

    Enable Hibernation This item allows users to enable or disable hibernation.  ACPI Sleep State This item allows users to set the ACPI sleep state.  Lock Legacy Resources This item allows users to lock legacy devices’ resources. SOM-6867 User Manual...
  • Page 28: Intel® Smart Connect Technology

    3.3.3 Intel® Smart Connect Technology Figure 3.6 Intel(R) Smart Connect Technology  ISCT Support Disable/Enable ISCT Support. SOM-6867 User Manual...
  • Page 29: W83627Dhg Super Io Configuration

    This item allows users to set parameters of Serial Port 0.  Serial Port 1 Configuration This item allows users to set parameters of Serial Port 1.  Parallel Port Configuration This item allows users to set parameters of Parallel Port (LPT/LPTE). SOM-6867 User Manual...
  • Page 30: Figure 3.8 Serial Port 0 Configuration

    Serial Port 0 Configuration Figure 3.8 Serial Port 0 Configuration  Serial Port This item allows users to enable or disable Serial Port (COM).  Change Setting This item allows users to select and optimal setting for Super IO device. SOM-6867 User Manual...
  • Page 31: Figure 3.9 Serial Port 1 Configuration

    Serial Port 1 Configuration Figure 3.9 Serial Port 1 Configuration  Serial Port This item allows users to enable or disable Serial Port (COM).  Change Setting This item allows users to select and optimal setting for Super IO device. SOM-6867 User Manual...
  • Page 32: Figure 3.10Parallel Port Configuration

    This item allows users to enable or disable Parallel Port (LPT/LPTE).  Change Setting This item allows users to select and optimal setting for Super IO device.  Device Mode This item allows users to change the Printer Port mode. SOM-6867 User Manual...
  • Page 33: Imanager Configuration

    This item allows users to select Ite8518 Power Saving Mode.  Serial Port 2 Configuration Set parameter of Serial Port 2.  Serial Port 3 Configuration Set parameter of Serial Port 3.  Hardware Monitor This item allows users to monitor hardware status. SOM-6867 User Manual...
  • Page 34: Figure 3.12Serial Port 2 Configuration

    3.3.5.1 Serial Port 2 Configuration Figure 3.12 Serial Port 2 Configuration  Serial Port Customer can enables or disables Serial Port (COM).  Change settings Users can select an optional setting for Serial Port. SOM-6867 User Manual...
  • Page 35: Figure 3.13Serial Port 3 Configuration

    3.3.5.2 Serial Port 3 Configuration Figure 3.13 Serial Port 3 Configuration  Serial Port COM Port 3 enables or disables Serial Port (COM).  Change settings Users can select an optional setting for Serial Port. SOM-6867 User Manual...
  • Page 36: Figure 3.14Hardware Monitor

    3.3.5.3 Hardware Monitor Figure 3.14 Hardware Monitor SOM-6867 User Manual...
  • Page 37: Serial Port Console Redirection

    Figure 3.15 Serial Port Console Redirection  Legacy Console Redirection Setting This item allows users to set Legacy console redirection settings.  Console Redirection This item allows users to enable or disable console redirection for Microsoft Windows Emergency Management Services (EMS). SOM-6867 User Manual...
  • Page 38: Cpu Configuration

    SuSE Linux 9.2, RedHat Enterprise 3 Update 3.).  Intel Virtualization Technology When enabled, a VMM can utilize the additional hardware capabilities provided by Vanderpool Technology.  Power Technology This item allows users to enable the power management features. SOM-6867 User Manual...
  • Page 39: Figure 3.17Socket 0 Cpu Information

    3.3.7.1 Socket 0 CPU Information Figure 3.17 Socket 0 CPU Information 3.3.7.2 CPU Thermal Configuration Figure 3.18 CPU Thermal Configuration SOM-6867 User Manual...
  • Page 40: Ppm Configuration

    PPM Configuration Figure 3.19 PPM Configuration  CPU C state Report This item allows users to enable CPU C state report to OS.  Max CPU C-state This option controls Max C state that the processor will support. SOM-6867 User Manual...
  • Page 41: Ide Configuration

    This item allows users to enable or disable SATA Port0 Hotplug.  Serial-ATA Port 1 This item allows users to enable or disable Serial ATA Port 1.  SATA Port1 HotPlug This item allows users to enable or disable SATA Port1 Hotplug. SOM-6867 User Manual...
  • Page 42: Network Stack Configuration

    3.3.10 Network Stack Configuration Figure 3.21 Network Stack Configuration  Network Stack This item allows users to enable or disable UEFI Network Stack. SOM-6867 User Manual...
  • Page 43: Csm Configuration

    This item controls the execution of UEFI and Legacy Storage OpROM.  Video This item controls the execution of UEFI and Legacy Video OpROM.  Other PCI devices This item determines OpROM execution policy for devices other than Network, Storage, or Video. SOM-6867 User Manual...
  • Page 44: Usb Configuration

    Maximum time the device will take before it properly reports itself to the Host Controller. “Auto” uses default value: for a Root port it is 100ms, for 1 Hub port the delay is taken from Hub descriptor. SOM-6867 User Manual...
  • Page 45: Security Configuration

    This item allows users to revert TXE settings to factory defaults.  Intel(R) AT This item allows users to enable/disable BIOS AT Code from running.  Intel(R) AT Platform PBA This item allows users to enable/disable BIOS AT Code from running. SOM-6867 User Manual...
  • Page 46: Chipset

    Chipset Select the Chipset tab from the SOM-6867 setup screen to enter the Chipset BIOS Setup screen. You can display a Chipset BIOS Setup option by highlighting it using the <Arrow> keys. All Plug and Play BIOS Setup options are described in this sec- tion.
  • Page 47: North Bridge

    Graphics Power Management Control This item allows users to configure Graphics Power Management Control options.  LCD Control This item allows users to control LCD setting.  MAX TOLUD This item allows users to set Maximum value of TOLUD. SOM-6867 User Manual...
  • Page 48 Graphics Device.  Aperture Size This item allows users to select Aperture Size.  DOP CG This item allows users to enable/disable DOP Clock Gating.  GTT Size This item allows users to select GTT Size. SOM-6867 User Manual...
  • Page 49 Default ISP is PCI B0D2F0 for Window Boot. Linux Boot to select B0D3G0. 3.4.1.2 Graphics Power Management Control Figure 3.28 Graphics Power Management Control  RC6 (Render Standby) This item allows users to enable/disable render standby support. SOM-6867 User Manual...
  • Page 50 This item allows users to select the LCD panel scaling option used by the Inter- nal Graphics Device.  Backlight Control This item allows users to select back light control setting.  Active LFP This item allows users to select “No LVDS” or “eDP Port-A”. SOM-6867 User Manual...
  • Page 51: South Bridge

    Serial IRQ Mode This item allows users to configure Serial IRQ Mode.  Global SMI Lock This item allows users to enable/disable SMI Lock.  BIOS Read/Write Protection This item allows users to enable/disable BIOS SPI region read/write protect. SOM-6867 User Manual...
  • Page 52 This item allows users to enable/disable Power Management capability of Audio Controller.  Audio HDMI Codec This item allows users to enable/disable internal HDMI codec for Azalia. – HDMI Port B This item allows users to enable/disable HDMI Port B. SOM-6867 User Manual...
  • Page 53 USB Port 1 This item allows users to enable/disable USB Port 1.  USB Port 2 This item allows users to enable/disable USB Port 2.  USB Port 3 This item allows users to enable/disable USB Port 3. SOM-6867 User Manual...
  • Page 54 This item allows users to enable/disable PCI Express Port 3 or onboard LAN. – Hot Plug This item allows users to enable/disable PCI Express Hot Plug. – Speed This item allows users to configure PCIe Port Speed. SOM-6867 User Manual...
  • Page 55: Security

    This item allows users to set Administrator Password.  User Password This item allows users to set User Password.  P1: SM611GX8 HDD Security Configuration for selected driver. (This item will be shown if onboard SSD is available) SOM-6867 User Manual...
  • Page 56: Boot

    This item allows users to enable or disable boot with initialization of a minimal set of devices required to launch active boot option. Has no effect for BBS boot options.  Boot Option Priority This item allows users to set the system boot order. SOM-6867 User Manual...
  • Page 57: Save & Exit

    Select this option to quit Setup without making any permanent changes to the system configuration and reboot the computer. 3.7.5 Save Changes When users have completed system configuration, select this option to save changes without exit BIOS setup menu. SOM-6867 User Manual...
  • Page 58: Discard Changes

    3.7.7 Restore Defaults The SOM-6867 automatically configures all setup items to optimal settings when users select this option. Optimal Defaults are designed for maximum system perfor- mance, but may not work best for all computer applications. In particular, do not use the Optimal Defaults if the user’s computer is experiencing system configuration...
  • Page 59 Enable: Enable XHCI Mode Disable: Disable XHCI Mode Auto: System will depend on previous boot setting in OS to enable/disable XHCI. Smart Auto: System will depend on previous boot setting in POST and OS to enable/disable XHCI. SOM-6867 User Manual...
  • Page 60: Bios/Fw Supported Matrix

    3.9.1. Operating System BIOS Environment VBIOS FW Windows/WES 7 Legacy VBIOS Windows Embedded Compact7 (Default) (Default) Windows/WES 8 Android Linux (Fedora 18/Yocto 18) * SOM-6867 standard product is configured with 64bis BIOS (Windows 7) SOM-6867 User Manual...
  • Page 61 SOM-6867 User Manual...
  • Page 62: S/W Introduction & Installation

    Chapter S/W Introduction & Installation Sections include:  S/W Introduction  Driver Installation  Advantech iManger...
  • Page 63: S/W Introduction

    It makes these embedded features easier to integrate, speed up develop- ing schedule, and provide the customer's software continuity while upgrade hard- ware. For more details of how to use the APIs and utilities, please refer to Advantech iManager 2.0 Software API User Manual. SOM-6867 User Manual...
  • Page 64 Chapter 4 S/W Introduction & Installation...
  • Page 65 SOM-6867 User Manual...
  • Page 66: Appendix A Pin Assignment

    Appendix Pin Assignment This appendix gives you the infor- mation about the hardware pin assignment of the SOM-6867 CPU System on Module Sections include:  SOM-6867 Type 6 Pin Assign- ment...
  • Page 67: A.1 Som-6867 Type 6 Pin Assignment

    SOM-6867 Type 6 Pin Assignment This section gives SOM-6867 pin assignments on COM Express connectors which are compliant with COMR.0 R2.1 Type 6 pin-out definitions. For more details about how to use these pins and getting the design reference, please contact Advantech for design guide, checklist, reference schematic, and other hardware/software support.
  • Page 68 GND (FIXED) LVDS_A0+ LVDS_B0+ LVDS_A0- LVDS_B0- LVDS_A1+ LVDS_B1+ LVDS_A1- LVDS_B1- LVDS_A2+ LVDS_B2+ LVDS_A2- LVDS_B2- LVDS_VDD_EN LVDS_B3+ LVDS_A3+ LVDS_B3- LVDS_A3- LVDS_BKLT_EN GND (FIXED) GND (FIXED) LVDS_A_CK+ LVDS_B_CK+ LVDS_A_CK- LVDS_B_CK- LVDS_I2C_CK LVDS_BKLT_CTRL LVDS_I2C_DAT VCC_5V_SBY GPI3 VCC_5V_SBY VCC_5V_SBY VCC_5V_SBY PCIE_CLK_REF+ BIOS_DIS1# SOM-6867 User Manual...
  • Page 69 VCC_12V B107 VCC_12V A108 VCC_12V B108 VCC_12V A109 VCC_12V B109 VCC_12V A110 GND (FIXED) B110 GND (FIXED) SOM-6867 Row C,D GND (FIXED) GND (FIXED) USB_SSRX0- USB_SSTX0- USB_SSRX0+ USB_SSTX0+ GND (FIXED) GND (FIXED) DDI1_CTRLCLK_AUX+ DDI1_CTRLDATA_AUX- RSVD RSVD RSVD RSVD GND (FIXED)
  • Page 70 GND (FIXED) GND (FIXED) DDI2_PAIR1+ (Option) DDI2_PAIR1- (Option) DDI2_HPD (Option) RSVD RSVD DDI2_PAIR2+(Option) DDI2_PAIR2- (Option) RSVD RSVD DDI2_PAIR3+ (Option) DDI2_PAIR3- (Option) GND (FIXED) GND (FIXED) GND (FIXED) GND (FIXED) RSVD RSVD RSVD RSVD RSVD GND (FIXED) GND (FIXED) SOM-6867 User Manual...
  • Page 71 GND (FIXED) C101 D101 C102 D102 C103 D103 C104 VCC_12V D104 VCC_12V C105 VCC_12V D105 VCC_12V C106 VCC_12V D106 VCC_12V C107 VCC_12V D107 VCC_12V C108 VCC_12V D108 VCC_12V C109 VCC_12V D109 VCC_12V C110 GND (FIXED) D110 GND (FIXED) SOM-6867 User Manual...
  • Page 72: Appendix B Watchdog Timer

    Appendix Watchdog Timer This appendix gives you the infor- mation about the watchdog timer programming on the SOM-6867 CPU System on Module Sections include:  Watchdog Timer Programming...
  • Page 73: Programming The Watchdog Timer

    ** WDT new driver support automatically select available IRQ number from BIOS, and then set to EC. Only Win7 and Win8 support it. In other OS, it will still use IRQ number from BIOS setting as usual. For details, please refer to iManager & Software API User Manual: SOM-6867 User Manual...
  • Page 74: Appendix C Programming Gpio

    Appendix Programming GPIO This Appendix gives the illustra- tion of the General Purpose Input and Output pin setting. Sections include:  System I/O ports...
  • Page 75: Gpio Register

    GPIO Register GPIO Byte Mapping H/W Pin Name BIT0 GPO0 BIT1 GPO1 BIT2 GPO2 BIT3 GPO3 BIT4 GPI0 BIT5 GPI1 BIT6 GPI2 BIT7 GPI3 For details, please refer to iManager & Software API User Manual SOM-6867 User Manual...
  • Page 76: Appendix D System Assignments

    Appendix System Assignments This appendix gives you the infor- mation about the system resource allocation on the SOM-6867 CPU System on Module Sections include:  System I/O ports  DMA Channel Assignments  Interrupt Assignments  1st MB Memory Map...
  • Page 77: System I/O Ports

    Printer Port (LPT1) Intel(R) Atom(TM) Processor E3800 Series/Intel(R) Celeron(R) 03B0-03BB Processor N2920/J1900 Intel(R) Atom(TM) Processor E3800 Series/Intel(R) Celeron(R) 03C0-03DF Processor N2920/J1900 03E8-03EF Communications Port (COM3) 03F8-03FF Communications Port (COM1) 0400-047F Motherboard resources 04D0-04D1 Programmable interrupt controller 0500-05FE Motherboard resources SOM-6867 User Manual...
  • Page 78: Dma Channel Assignments

    Intel® Atom™/Celeron®/Pentium® Processor PCI Express - Root IRQ 18 Port 3 - 0F4C IRQ 19 Intel® Atom™/Celeron®/Pentium® Processor AHCI - 0F23 Intel® Atom™/Celeron®/Pentium® Processor PCI Express - Root IRQ 19 Port 4 - 0F4E IRQ 22 High Definition Audio Controller SOM-6867 User Manual...
  • Page 79: 1St Mb Memory Map

    Intel® Atom™/Celeron®/Pentium® Processor AHCI - 0F23 0x909157FF 0xE0000000- Motherboard resources 0xEFFFFFFF 0xFED01000- Motherboard resources 0xFED01FFF 0xFED03000- Motherboard resources 0xFED03FFF 0xFED04000- Motherboard resources 0xFED04FFF 0xFED08000- Motherboard resources 0xFED08FFF 0xFED1C000- Motherboard resources 0xFED1CFFF 0xFEE00000- Motherboard resources 0xFEEFFFFF 0xFEF00000- Motherboard resources 0xFEFFFFFF SOM-6867 User Manual...
  • Page 80 Intel® Atom™ Processor E3800 Series/Intel® Celeron® Processor 0x903FFFFF N2920/J1900 0x90914000- Intel® Atom(TM)/Celeron®/Pentium® Processor Platform Control 0x9091401F Unit - SMBus Port - 0F12 0xFED00000- High precision event timer 0xFED003FF 0x90600000- Intel(R) Atom(TM)/Celeron(R)/Pentium(R) Processor PCI Express 0x908FFFFF - Root Port 4 - 0F4E SOM-6867 User Manual...
  • Page 81 www.advantech.com Please verify specifications before quoting. This guide is intended for reference purpOS only. All product specifications are subject to change without notice. No part of this publication may be reproduced in any form or by any means, electronic, photocopying, recording or otherwise, without prior written permis- sion of the publisher.
  • Page 82 Our company network supports you worldwide with offices in Germany, Austria, Switzerland, Great Britain and the USA. For more information please contact: FORTEC Elektronik AG FORTEC Elektronik AG Hauptniederlassung Büro West Lechwiesenstr. 9 Hohenstaufenring 55 86899 Landsberg am Lech 50674 Köln...

Table of Contents