6.2. SX-2000CO Control Output Unit ..20 Note Two modes of operation are made available for the SX-2000CI and SX-2000CO: Normal mode where the unit operates within the SX-2000 system and Stand-alone mode where the unit operates independently of the SX-2000 system.
· When connecting the power cord of the DC may cause fire or electric shock. power supply panel for the SX-2000CI/CO to an · If you detect smoke or a strange smell coming AC outlet, ensure that the total load current never from the unit.
The front-mounted indicators of each unit show the control input status or control output status. The SX-2000CI and SX-2000CO are 1U-size* units that can be mounted in an EIA equipment rack. It has 2 power supply inputs, one of which can be connected to a backup power source to protect against power failures.
ID NUMBER RESET SETTING 1. Control Input Indicators 8. Reset Key [RESET] [CONTROL INPUT 1 – 32] (Green) Pressing this key restarts the SX-2000CI. Light when the corresponding control inputs are turned ON. 9. DIP Switch [SETTING] • Switch 1 2.
Page 5
[Rear] 14 15 CONTROL INPUT CI/CO LINK DC 24V OUT THROUGH DATA MAX. 0.1A 10. Functional Earth Terminal [SIGNAL GND] 13. Control Input Terminals Hum noise may be generated when external [CONTROL INPUT 1 – 32] equipment is connected to the unit. Connecting Photo coupler inputs.
4. FAULT Indicator [FAULT] (Yellow) Sets operation mode. (See p. 15.) Lights when communications with the connected ON: Operates in stand-alone mode. SX-2000CI are interrupted. OFF: Operates in normal mode. 5. USB Port [USB] • Switches 2 – 8 This port is not used.
Page 7
When driving the unit with the power supply unit 15. CI/CO Link Data Terminal [CI/CO LINK DATA] connected to the SX-2000CI, connect the power Connect this terminal to the CI/CO Link Terminal supply to this terminal via an optional RM-200RJ of the SX-2000CI.
4. CONNECTIONS 4.1. Removable Terminal Plug Connection Notes • Do not use a micro screwdriver. Sufficient torque is not given to the screws when tightening them, and connections may not be secured. • Avoid soldering stranded or shielded cable, as contact resistance may increase when the cable is tightened and the solder is crushed, possibly resulting in an excessive rise in joint temperatures.
Note: For the detailed information on the connections of power supply unit and CI/CO links, refer to the page indicated at the end of each "Connection example." 4.2.1. Connection example 1 Connect each 2 power supply units to the SX-2000CI and SX-2000CO separately. (See p. 10 and 15.) Program timer SX-2000CI...
A channel of the DC power input terminal and the other power supply unit to the B channel of the DC power input terminal on the SX-2000CI. Connect the power supply units to the SX-2000CO in the same manner.
Page 11
Both the SX-2000CI and SX-2000CO can be driven by connecting 2 power supply panels to the SX-2000CI only. Connect the DC power input terminals of the SX-2000CI to those of the SX-2000CO and the CI/CO link data terminals of the SX-2000CI to those of the SX-2000CO via the RM-200RJ Terminal Unit (optional).
Page 12
AWG14 – 18 STP Category 5 straight cable (with RJ45 connectors) Shield AWG14 – 18 SX-2000CI Over 3-pair shielded RM-200RJ CPEV cable (main cable) CI/CO link data terminal DC power input terminal AWG14 –...
Page 13
Note When connecting the power supply unit to one of the equipment, be sure to connect it to the SX-2000CI side. If it is connected to the SX-2000CO side, the maximum cable length between the SX-2000CI and SX-2000CO may be reduced.
4.4. Control Input Connections (SX-2000CI Only) This connection example allows timer-activated automatic broadcasts. When the TT-104B's preprogrammed time is reached, the SX-2000CI receives a control output signal (make contact) from the TT-104B and activates preset broadcast patterns. TT-104B OUTPUT CHANNEL (24 V DC 0.5 A) program timer OUTPUT CHANNEL (24 V DC 0.5 A)
THROUGH DATA CI/CO link through switch: OFF (Factory preset: OFF) The SX-2000CI and SX-2000CO can be connected using the shielded CPEV cable (1-pair for data line) via the optional RM-200RJ Terminal unit. Note Total cable length connecting CI/CO link terminals within the system must be kept shorter than 800 m.
Step 3. Set the link through switch on the SX-2000CI/CO's rear panel to the OFF position. Note: The CI/CO link through switch is set to OFF by default. SX-2000CI rear CI/CO LINK THROUGH DATA CONTROL INPUT CI/CO LINK DC 24V OUT THROUGH DATA MAX.
Page 17
5.2.1. No priority control (DIP switch 3: OFF, DIP switch 4: OFF) In this mode, priority control is disabled. (Factory default) SETTING For example, closing the control input 2 while the control input 1 is closed causes the control output 2 to close simultaneously while the control output 1 remains closed.
Page 18
5.2.3. Last-in-first-out (DIP switch 3: OFF, DIP switch 4: ON) The most recent control input takes precedence over the earlier one. SETTING For example, closing the control input 2 while the control input 1 is closed causes the control output 1 to open. The control output 1 becomes closed when the control input 2 is opened.
Shielded CPEV cable* or STP Category 5 straight cable * When connecting the power supply to each unit: 1-pair for data line When connecting the power supply only to the SX-2000CI: 1-pair data line and 2-pair power line for a redundant power supply...
Shielded CPEV cable* or STP Category 5 straight cable * When connecting the power supply to each unit: 1-pair for data line When connecting the power supply only to the SX-2000CI: 1-pair data line and 2-pair power line for a redundant power supply...