MegaVideo MPV-QE-SD User Manual

Prime hdr ir bullet ip camera

Advertisement

Quick Links

Prime HDR
IR Bullet IP Camera
User's Manual
Ver. 1.5
MPV-QE-SD & SH
001B0EQXZ1A5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MPV-QE-SD and is the answer not in the manual?

Questions and answers

Summary of Contents for MegaVideo MPV-QE-SD

  • Page 1 Prime HDR IR Bullet IP Camera User’s Manual Ver. 1.5 MPV-QE-SD & SH 001B0EQXZ1A5...
  • Page 2: Table Of Contents

    Table of Contents Overview ..........................2 Features ........................2 Package Contents ....................... 3 Dimensions ........................4 microSD Card Slot / Factory Default Button ..............5 Camera Cabling ........................6 All-in-One Cable ......................6 Connect Power ......................7 Connect Ethernet Cable....................7 Connect Alarm I/O .......................
  • Page 3: Overview

    Overview The Prime HDR IR Bullet IP Camera is a high-end surveillance solution with compact and easy set-up design. Supporting up to 3M real-time video and Quad Streams Codec (H.264 Baseline/ Main / High Profile + MJPEG), the camera offers supreme image quality while keeping efficient bandwidth for storage management.
  • Page 4: Package Contents

    Package Contents Please check the package containing the following items listed below. Prime HDR IR Bullet IP Camera (cable included) 5-Pin Alarm Terminal Block 2-Pin Power Terminal Block Plastic Screw Anchor (x5) M5 Standard Screw (x1) M4 Self-Tapping Screw (x5) Quick Guide NOTE: Users MUST pre-drill and use plastic anchors before fastening the supplied self-tapping screws on the wall.
  • Page 5: Dimensions

    Dimensions The dimensions of the camera are shown below.
  • Page 6: Microsd Card Slot / Factory Default Button

    microSD Card Slot / Factory Default Button The camera’s microSD card slot and factory default button are inside the front housing. If users need to use them, the front housing must be opened. Follow the steps below to reach microSD card slot and factory default button. Step 1: Loosen the screw on the camera housing but do not detach it.
  • Page 7: Camera Cabling

    Camera Cabling Before users connect cables, make sure that all cables and the power adaptor are placed in dry and well-waterproofed environments, e.g. waterproof boxes. The purpose is to prevent moisture accumulation inside the camera and moisture penetration into cables, which might lead to camera breakdown. Please refer to the following sections to complete camera connection.
  • Page 8: Connect Power

    Connect Power For power connection, please use an AC 24V / DC 12V adaptor and connect it to the 2-pin terminal block of the All-in-One cable and the power outlet. Alternatively, users can power the camera by PoE if a Power Sourcing Equipment (PSE) switch is available.
  • Page 9: Waterproof Cable Connectors

    Waterproof Cable Connectors Follow the steps below to waterproof the connectors of the All-in-One cable. Step 1: Connect the required devices to the All-in-One cable and coat the joints with silicone gel. There should be no gap between the connectors and the cables. For alarm I/O connector and power connector, make sure the side with wires attached is also sealed with silicone gel.
  • Page 10: Installation

    Installation Please read the instructions provided in this chapter thoroughly before installing the camera. Ceiling / Wall Mounting The camera can be installed directly on a wall or ceiling with the integrated 2-axis adjustable Bracket Mount. Please note that the wall or ceiling must have enough strength to support the camera.
  • Page 11 Step 2: At the center of the two marked holes, drill a 30 mm diameter (radius as 15 mm) cable entry hole. Then drill a hole slightly smaller than the supplied plastic screw anchor on each marked screw hole. Step 3: Thread the All-in-One cable of the camera through the cable entry hole.
  • Page 12: System Requirements

    System Requirements To perform the camera via web browser, please ensure the PC is in good network connection, and meet system requirements as described below. Items System Requirement Minimum : 1. Intel® Core i5-2430M @ 2.4 GHz 2. 4 GB RAM Personal Computer Recommended : 1.
  • Page 13: Access Camera

    Access Camera For initial access to the IP camera, users can search the camera through the installer program: DeviceSearch.exe. Accessing the Camera by Device Search Software Step 1: Double click on the program Device Search.exe. Step 2: After its window appears, click on the <Device Search> button on the top.
  • Page 14 Step 8: A prompt window requesting for default username and password will appear. Enter the default username and password shown below to login to the camera. Login ID Password Admin 1234 NOTE: ID and password are case sensitive. NOTE: It is strongly advised that administrator’s password be altered for the security concerns.
  • Page 15 Once the Viewer is successfully installed, the Home page of the IP camera will be displayed as the figure below. Motorized Lens Models...
  • Page 16 AF Lens Models Zoom and Focus Adjustment The live image will be displayed on the Home page when the camera is successfully accessed. If zoom or focus is not at the desired position, please use the function buttons on the Home page to adjust zoom and focus. NOTE: Please refer to the Prime HDR IP Camera Menu Tree for more button function details.
  • Page 17: Setup Video Resolution

    Setup Video Resolution Users can setup video resolution on Video Format page of the user-friendly browser-based configuration interface. Video Format can be found under this path: Streaming> Video Format. The default values of video resolution are as below. H.264- 1920 x 1080 (30/25 fps)+ Normal Mode H.264.- 1280 x 1024(30/25 fps) H.264- 1920 x 1080 (30/25 fps)+...
  • Page 18: Configuration Files Export / Import

    Configuration Files Export / Import To export / import configuration files, users can access the Maintenance page on the user-friendly browser-based configuration interface. The Maintenance setting can be found under this path: System> Maintenance. Users can export configuration files to a specified location and retrieve data by uploading an existing configuration file to the camera.
  • Page 19: Tech Support Information

    Tech Support Information This chapter will introduce how to delete previously-installed DCViewer in the PC and how to setup the Internet security. Delete the Existing DCViewer For users who have installed the DCViewer in the PC previously, please first remove the existing DCViewer from the PC before accessing to the IP camera. Deleting the DCViewer In the Windows <Start Menu>, activate <Control Panel>, and then double click on <Add or Remove Programs>.
  • Page 20: Setup Internet Security

    Setup Internet Security If ActiveX control installation is blocked, please either set Internet security level to default or change ActiveX controls and plug-ins settings. Internet Security Level: Default Step 1: Start the Internet Explorer (IE). Step 2: Click on the <Tools> tab on the menu bar and select <Internet Options>.

This manual is also suitable for:

Mpv-qe-sh

Table of Contents