Summary of Contents for Accuniq BP250

  • Page 2 The device bears the CE label in accordance with the provisions of Medical Device Directive 93/42/EEC. THE PERSONS RESPONSIBLE FOR PLACING DEVICES ON THE EC MARKET UNDER MDD 93/42/EEC SELVAS Healthcare, Inc. 155, Shinseong-ro, Yuseong-gu, Daejeon, 34109 Republic of Korea TEL: 82-42-879-3000, FAX: 82-42-864-4462 VITAKO Sp.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS • INTRODUCTION ..................... 1. IINTENDED USE................... 2. WORD DEFINITIONS..................3. CLASSIFICATION AND COMPLIANCE............4. SAFETY PRECAUTIONS................5. SAFETY SYMBOLS AND INFORMATION............ 6. Guidance for Electromagnetic compatibility (EMC) ........• TERMS OF EACH PART AND FUNCTIONS ..........1. FRONT PART....................2.
  • Page 4: Introduction

    We will provide you with detailed instructions. 1. INTEDED USE ACCUNIQ BP250 Automatic Blood Pressure Monitor is designed to measure systolic and diastolic blood pressure and pulse rate of Persons who are 18 years and older using the oscillometric method on a cuffed arm.
  • Page 5: Classification And Compliance

    3. CLASSIFICATION AND COMPLIANCE 1) This device is classified as; - Class 1 type-BF against electric shock - Ordinary equipment without protection against ingress of water - Equipment not suitable for use in presence of a flammable anesthetic mixture by standard of EN 60601-1: 2006(Basic safety and essential performance of Medical Electrical Equipment) 2) This device is complied with Class A for Noise-Emission, Level B for Noise-immunity, by standard of IEC 60601-1-2:2007(Electromagnetic Compatibility Requirements).
  • Page 6 - Where the ambient temperature falls -20°C or exceeds 60°C. - Where the atmospheric pressure falls below 70kPa (700mbar) or exceeds 106kPa (1060mbar). - Where the humidity is over 95% non-condensing. - Where the unit is exposed to spray or splashing water. - Where the unit is exposed to dust.
  • Page 7 1. Measurements may be impaired if this device is used near televisions, microwave Caution ovens, X-ray equipment or other devices with strong electrical fields. To prevent such interference, use the meter at a sufficient distance from such devices or turn them off.
  • Page 8: Safety Symbols And Information

    5. SAFETY SYMBOLS AND INFORMATION The International Electrotechnical Commission (IEC) has established a set of symbols for medical electrical equipment which classifies a connection or warning of any potential hazard. The classifications and symbols are shown below. Save these instructions for your safety. Degree of protection against electric shock: TYPE BF Please observe operating instructions General warning sign...
  • Page 9 This symbol is used inside system. Identifies the point where the safety ground of the system is fastened to the chassis. Do not open. This is for factory only. Alternating current Direct current Date of manufacture Manufacturer Non-ionizing radiation CE mark Serial No.
  • Page 10: Guidance For Electromagnetic Compatibility (Emc)

    1) Guidance and manufacturer’s declaration – electromagnetic emissions The ACCUNIQ BP250 is intended for use in the electromagnetic environment specified below. The customer or the user of the ACCUNIQ BP250 should assure that it is used in such an environment. Electromagnetic environment – guidance...
  • Page 11 70 % UT interruptions, it is recommended that supply line IEC (30 % dip in UT) (30 % dip in UT) the ACCUNIQ BP250 be powered 61000-4-11 for 25 cycles for 25 cycles from an uninterruptible power supply <5 % UT <5 % UT...
  • Page 12 3) Guidance and manufacturer’s declaration – electromagnetic immunity 2 The ACCUNIQ BP250 is intended for use in the electromagnetic environment specified below. The customer or the user of the ACCUNIQ BP250 should assure that it is used in such an environment. Compliance...
  • Page 13 4) Recommended separation distances between portable and mobile RF communications equipment and the ACCUNIQ BP250 The ACCUNIQ BP250 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the ACCUNIQ BP250 can help prevent...
  • Page 14 frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. Caution 1. At 80 MHz and 900 MHz, the separation distance for the higher frequency range applies. 2.
  • Page 15: Terms Of Each Part And Functions

    TERMS OF EACH PART AND FUNCTIONS 1. FRONT PART ① START BUTTON Press START button after being ready to measure, the cuff will be wrapped automatically and begins to pressurize. ② STOP BUTTON Press STOP button if you want to stop it during measurement. Pressurizing will stop and the air will exhaust from the cuff.
  • Page 16 Note The cuff and the buttons (START and STOP button) of this device are located at reverse side by R and L type. FRONT PART ⑧ ARM REST ④ CLOCK SECTION ③ LCD DISPLAY ⑪ RFID CARD-READER ⑦ CUFF ⑩ MAGNETIC CARD-READER ①...
  • Page 17: Printer

    2. PRINTER ① PRINT button - Use it when you print out the data. - If you set [ON] at the rear (PRINT ON/OFF switch), the data is printed automatically even when you do not press PRINT button. - Normally, when you press this button, all the data output after you turn the power on will be printed. (If you turn it off, all memorized data would be deleted.) - When you set the date and time, the number goes up with this button pressed.
  • Page 18: Rear Part

    3. REAR PART ① POWER It is used to turn the power on and off. ② POWER INPUT It is used to connect with the adapter. ③ CAL This is only for inspection. Never open it. ④ EARTH (POTENTIAL EQUALIZATION TERMINAL) Please make sure for safety.
  • Page 19 1. While sound switch is activated on (so sound is functioning), place the VOLUME Note ON/OFF switch to [OFF] for deactivation of voice message and music play. 2. Printer, card reader, human sensor and reverse monitor is optional. 3. The operator should not touch both USB port and the patient’s body simultaneously.
  • Page 20: Accessories

    4. ACCESSORIES Adapter/Power cable User guide Guide 5. OPTIONS Cart / Chair RFID Card/Magnetic Card Thermal paper / Printer Human sensor Reverse monitor Reverse monitor support/cable - 20 -...
  • Page 21: Installation

    INSTALLATION 1. CONNECTION ADAPTER Just connect the power cable to the adapter on the rear and turn the POWER ON/OFF switch on the lower part of the rear (See the picture). Caution In order to avoid the risk of electrical shock, connect this device only to the power supply equipped with the protective grounding.
  • Page 22: Connecting Ports

    Being thermal type, printing is photocopied on one side of the paper (slippery side), Note without using printing ink. Please check remainder of the paper always and then replace it. Please use exclusive paper (58mm). Keep paper rolls in a dark and ventilated place. Avoid any dust on the paper.
  • Page 23: Setting Time And Date

    4. SETTING TIME AND DATE - Turn the power of the unit on. - Open the printer cover. - Sequence is HOUR → MINUTE → MONTH → DAY → YEAR HOUR Press SET button, then DATE and TIME will blink. At that time, press PRINT button.
  • Page 24 Note If you want to measure blood pressure during setting the date and time, press STOP button. Then you can measure again immediately. You should set all data at once (hour, minute, month, day and year). Note In case of stopping setting, the values return to previous ones which you have done before.
  • Page 25: System Setup

    SYSTEM SETUP Set the Operating Conditions for the device. 1. Entering SYSTEM SETUP If press the ‘STOP’ button for 3~5seconds, there is chime bell as ‘PPI~~’ three times. At that time, press the ‘START’ button as pressing the ‘STOP’ button at the same time then enter the system setup mode 2.
  • Page 26: Setup

    6. Setup <BGM> Set the BGM environment. - Pre-set: 10minutes (Music coming out with 10 minute’s interval) - Select ‘BGM’ with “STOP” button and press “START” button to move to the configuration window. - Select desired items with “STOP” button. - Save it to the unit by pressing “START”...
  • Page 27 <Date type> Set the Date Format to be displayed. - Pre-set: YY-MM-DD (Year-Month-Day) - Select ‘Date type’ with “STOP” button and press “START” button to move to the configuration window. - Select desired items with “STOP” button. - Save it to the unit by pressing “START” button. - Press “STOP”...
  • Page 28 <SYSTEM> Change the setting of the device environment. Select the ‘SYSTEM’ on main screen ‘SYSTEM SETUP’, and then enter the Menu. Display by ‘Date/Time’, ‘LOGO’, ‘Product initialization’ of menu. ① Date / Time Set the current date and time. - Setting on basic: the date of factory release - Select the ‘Date/Time’...
  • Page 29: Measurement

    MEASUREMENT 1. CAUTIONS FOR MEASUREMENT - 29 -...
  • Page 30: Measurement

    2. MEASUREMENT ① Check the voltage and turn the power on. Note With the human sensor attached optionally, the LCD screen is automatically turned on as it detects a user coming to the range. The sensor should be placed [ON]. ②...
  • Page 31 ④ Press the START button. Checking blood pressure begins as the cuff is automatically pressurized with the LCD screen displaying animations of the checking in process. When the measurement is started, the voice Caution “Starting message announced measurement, don’t move or speak please.” When you feel painful and want to stop the measurement, press...
  • Page 32 Note When the PRINT ON/OFF switch on the rear is set as 「OFF」, the result will not be printed even if the measurement is completed. Note For the card users, six previous results stored in the card can be recalled to compare with the current ones newly checked.
  • Page 33: Data On Measurement By Printer

    3. DATA ON MEASUREMENT BY PRINTER ▼ Results on Printing Paper ▼ LCD Display ▼Classification of the blood pressure : National High Blood Pressure Education Program, National Heart, Lung and Blood institute, NIH (JNC7, 2003) - 33 -...
  • Page 34 - When pressure is high with the jammed air hose, message appears on the printer as Note ERROR PRESSURE. When the message is repeated, call for maintenance service. - When pressure is low as air leaks, message appears on the printer as ERROR CUFF.
  • Page 35 OPTION 1. Reverse monitor 1) Attachment of the reverse monitor ① Put support of reverse monitor in the direction of arrow. ② Attach reverse monitor into reverse monitor support as above. ③④ Put guide board in the direction of arrow and then complete it. 2) Connect Connect reverse monitor and a blood pressure monitor to the rear ‘BACK MONITOR PORT’...
  • Page 36 ⑥ Weight button Used when putting user’s body weight. ⑦ Height button Used when putting user’s height. ⑧ Numbers and • button Used when putting numbers such as ID, weight, height etc. Use ‘•’ button in order to put a decimal point in case of body weight, height. For example, if body weight is 68.9kg, put ‘weight button→6→8→•→9’...
  • Page 37 4) Measurement ① Input data ID: After pressing ‘ID’ button in the initial screen, put ID, using 0~9 numeric button. - ID limitation you can put is 000000001~999999999. Weight: After putting ID, press ‘WEIGHT’ button, you put body weight, using 0~9 numeric button.
  • Page 38 ③ Result When measurement is complete, body mass index (B.M.I.), fatness is displayed based on ID, weight and height in LCD. ④ Standard for judging result • Body Mass Index (B.M.I.): this is calculated by dividing body weight by the square of height in meter. thin normal overweight...
  • Page 39 2. MAGNETIC CARD Machine manager can issue cards through supportive card issuer, in machine’s delivery, you can issue it yourself. When machine manager issues cards, please refer to card issuer or program manual. 1) Setting In card’s using, you should set CARD ON/OFF in the rear part by ‘ON’.
  • Page 40 When measurement started, cuff pressure begins. Animation notifying “measuring” appears. ③ Result When the measurement is completed, systolic blood pressure, diastolic blood pressure, pulse and assessment of blood pressure and pulse wave pattern is displayed in the result screen. - 40 -...
  • Page 41 ④ Print-out the result of the measurement ▼ Using only magnetic card ▼ Magnetic Card + reverse monitor - 41 -...
  • Page 42 3. RFID card Machine manager can issue cards through supportive card issuer, in machine’s delivery, you can issue it yourself. When machine manager issues cards, please refer to card issuer or program manual. 1) Setting In card’s using, you should set CARD ON/OFF in the rear part by ‘ON’.
  • Page 43 When measurement started, cuff pressure begins. Animation notifying “measuring” appears. ③ Result When the measurement is completed, systolic blood pressure, diastolic blood pressure, pulse and assessment of blood pressure and pulse wave pattern is shown in the result screen. 1. In using card(Magnetic&RFID card), previous measured result is stored by six Note times, it shows the total seven times measured result including current measure result.
  • Page 44 ④ Print-out the result of the measurement ▼ Using only RFID card ▼ RFID card+ input data on the reverse monitor - 44 -...
  • Page 45: Maintenance

    MAINTENANCE - 45 -...
  • Page 46 - 46 -...
  • Page 47: Error&Repair

    ERROR & REPAIR Error Cause Repair ERROR PRESSURE pressure is high with the When message jammed air hose repeated, call maintenance service. ERROR CUFF pressure is low as air leaks When message repeated, call maintenance service. - Don’t move or speak. ERROR MEASURE subject moves or speaks while in testing...
  • Page 48: After Service

    AFTER SERVICE 1. AFTER SERVICE If there is any problem with the unit, please follow the steps below; ※ Contact our company’s Overseas Service Department immediately. After gathering the model name, Serial Number, date of purchase and description of the problem, contact our company with information shown below.
  • Page 49: Specification

    SPECIFICATION ACCUNIQ BP250 ACCUNIQ BP250 Model (Right type) (Left type) Measuring Method Oscillometric Display mode 7inch wide color LCD display Systolic/Diastolic/Mean blood pressure, Pulse pressure, Pulse, Blood pressure assessment, Pulse wave pattern Result Contents Reverse Monitor(Option): Systolic/Diastolic blood pressure, Pulse, ID No, B.M.I., and Fatness...
  • Page 50: Warranty

    WARRANTY WARRANTY Item Automatic Blood Pressure Monitor Warranty period Model ACCUNIQ BP250 2years (main unit only) Serial NO. Date of purchase Month Year Name: TEL: Customer Address: Name: TEL: Dealer Address: Date Defection Confirmation Note - When you receive this warranty, make sure that the name of the dealer and the month, day and year of purchase are all completed.
  • Page 51 Pass/Fail 4 Measurement Proper measurement Pass/Fail General Judgment Pass/Fail Model ACCUNIQ BP250 Serial No. Installation place Date of purchase Check date Checked by Approved by Copy this sheet for use If repair is required, write down so in the Remarks column.
  • Page 52 Pass/Fail Other 1 Clock Present date/time Pass/Fail General Judgment Pass/Fail Model ACCUNIQ BP250 Serial No. Installation place Date of purchase Check date Checked by Approved by Copy this sheet for use If repair is required, write down so in the Remarks column.
  • Page 53 EUROPEAN REPRESENTATIVE VITAKO Sp. z o.o. ul. Stanisława Żaryna 7c 02-593 Warszawa, POLAND TEL: +48 505 522 888 BP250E-20170918 Rev 2.0...