Download Print this page

Continuum Maestro Owner's Manual

Pedicure spas

Advertisement

Quick Links

Continuum
Pedicure Spas
®
OWNER'S MANUAL
®
MAESTRO
PEDICURE SPA
Continuum Footspas, LLC P.O. Box 363 Brookfield, WI 53008
Toll Free: 1.877.255.3030 Telephone: 262.754.4900 Fax: 262.754.4901 MyContinuumPedicure.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the Maestro and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Continuum Maestro

  • Page 1 Continuum Pedicure Spas ® OWNER’S MANUAL ® MAESTRO PEDICURE SPA Continuum Footspas, LLC P.O. Box 363 Brookfield, WI 53008 Toll Free: 1.877.255.3030 Telephone: 262.754.4900 Fax: 262.754.4901 MyContinuumPedicure.com...
  • Page 2 To the original owner of our pedicure chairs, Continuum Footspas may repair or replace, at its option, any pedicure chairs found to be defective in material or workmanship upon inspection by a factory authorized representative of Continuum Footspas.
  • Page 3 ® Introduction ® The entire team at Continuum Footspas sincerely thanks you for choosing one of our pedicure chairs. We fully realize you had a choice and we look forward to making absolutely sure you made the right choice. A tremendous amount of time and energy has gone into designing and manufacturing not only a beautiful looking pedicure chair, but a pedicure chair that will perform trouble free for many years.
  • Page 4 Very Important Requirements Every Continuum pedicure chair must be installed by a licensed plumber and licensed electrician. Installation must comply with all national, state and local building codes and/or regulations. Your pedi- cure chair will not operate properly unless it has sufficient water pressure and temperature, proper drainage and adequate electrical power.
  • Page 5 1. DANGER: RISK OF ELECTRIC SHOCK. Connect ONLY to a circuit protected by a ground-fault circuit-interrupter (GFCI). 2. GROUNDING IS REQUIRED. Every Continuum pedicure chair MUST be installed by a qualified service representative and MUST be properly grounded. Also, the designated outlet MUST be grounded.
  • Page 6 5. Do not operate your pedicure chair without the jet covers attached to the jet housing. 6. Any Continuum pedicure chair must be connected only to a supply circuit that is protected by a ground fault circuit-interrupter (GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis.
  • Page 7 Remove and discard all packing and lifting materials. Installation Instructions EVERY CONTINUUM PEDICURE CHAIR MUST BE INSTALLED BY A LICENSED PLUMBER AND A LICENSED ELECTRICIAN. INSTALLATION MUST COMPLY WITH ALL NATIONAL, STATE AND LOCAL BUILDING CODES AND/OR REGULATIONS. FAILURE TO COMPLY WITH THESE CODES AND/OR REGULATIONS WILL RESULT IN THE LIMITED WARRANTY BEING NULL AND VOID.
  • Page 8: User Maintenance Instructions

    Cleaning and Disinfecting Products Your state board requires disinfecting of your pedicure basin. Continuum recommends “Splish Splash One-Step Disinfectant.” The following page outlines the benefits of Splish Splash together with contact information.
  • Page 10 If the wet end is not positioned correctly, damage to the jet may occur due to misalignment. This will NOT be covered by any Continuum warranty. Never turn the jet on without adequate water in the basin. There must be at least one (1) inch of water above the motor housing.
  • Page 11 ● Use of this product should be pleasant and comfortable. Should pain or discomfort result, discontinue use and consult your physician. WARNING: WHEN USING CONTINUUM PEDICURE CHAIRS, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING: 1. READ AND FOLLOW ALL INSTRUCTIONS.
  • Page 12: Chair Control

    Client Chair Control Keypad The Maestro utilizes two Chair Control Keypads, one located on the arm for the client; the other located on the front panel for the technician. Both keypads control forward/backward and tilting of the chair. The chair will automatically stop when fully tilted, full forward/backward or when a movement button is released.
  • Page 13: Operational Summary

    All Maestro Pedicure Spas feature an I Fill system ( Auto Fill) with two (2) “pipeless” magnetic jets. Your Maestro is equipped with I Fill 3. Two (2) “magnetic” jets are utilized. With “magnetic” jets, the entire front jet cover assembly is removable for cleaning and disinfecting. The impeller is held in place by a strong magnet together with a corresponding magnet embedded in the jet body.
  • Page 14 ™ Operating Instructions for Standard i-Fill System (Auto Fill) (The Standard Auto Fill System is included in all Maestro Models) NOTE: The standard I-Fill system cannot be used with liners. If liners are desired, one must order I-Fill 3. Step #1) LIFT AND TURN chrome handle for Hot/Cold water valve located in front of spa.
  • Page 15 USER’S MANUAL iFill Spa Control System iFill 3 MODEL L0903A NOTE: I-Fill 3 was designed to work with or without liners. The standard I-Fill system cannot be used with liners. MasterBox Control Keypad When using electrical equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury.
  • Page 16 AND COLD WATER LINES TO AVOID LOSING HOT WATER FROM ONE CHAIR TO THE OTHER. System Installation A capacitive sensor with advanced electronics and firmware are used to detect the water level. This technology can also work with a disposable liner. © 2017 Continuum Footspas, LLC iFill 3 - August, 2017...
  • Page 17 (Fig. 4), sensor. This delay allows the user to set the preferred water level in automatic fill mode. Fig. 4: Time delay setting © 2017 Continuum Footspas, LLC iFill 3 - August, 2017...
  • Page 18 © 2017 Continuum Footspas, LLC iFill 3 - August, 2017...
  • Page 19 LEG SUPPORTS, MASSAGE SYSTEM and OPTIONS LEG SUPPORTS he Maestroʼs leg supports have been designed and engineered to lock in the up position for dual and independent feet and calf treatment. To utilize one or both leg supports, using both hands at the base of the support, simply pivot it inward until it stops.
  • Page 20: Care And Maintenance

    BASIN, UPHOLSTERY, and LEG SUPPORTS Basin The Maestroʼs solid surface basin is extremely durable and stain resistant. In addition to cleaning and disinfecting procedures as outlined by your state board, one may choose to scrub the basin as well. Simply use a fine nylon scouring pad (ie; Scotch Bright™ #6448 or #7448) together with a good cleaning powder (ie;...