Page 1
An iSCAN™ utilizes a low power, wireless, radio operating in the 2.4 GHz band as its primary mode of communication. The wireless radio operates in compliance with IEEE Standard 802.15.4-2006.
5. The iSCAN™ has non-volatile on board data storage which may collect data for later upload. 6. iSCAN™ provides date time stamps for all data. The onboard clock for the iSCAN™ is set to UTC by readers in the network.
Please note that the iSCAN™ uses the same command list as the iTAG™ command list. For iSCAN™ command and control, please refer to the iTAG™ Command List for a complete description of commands that control the iSCAN™...
Under no circumstances must the absolute maximum ratings giving in this table be violated. Stress exceeding one or more of the limiting values may cause permanent damage to the device. Parameter Units Condition Users must utilize an iControl provided ™. Charger Supply Voltage charging cradle for the iSCAN Polarity protected.
Incorporated http://www.iControl-Inc.com General Characteristics. (1) Programmable in 5MHz steps starting at 2405MHz per IEEE 802.15.4 iSCAN™ Radio Specification (Transmit).
Page 6
Incorporated http://www.iControl-Inc.com iSCAN™ Radio Specification (Receive).
Page 7
Module Unique Address Identification. Each iSCAN™ is assigned a unique 8 byte MAC address by iControl Incorporated. The MAC address is used for radio network address identification. The MAC address can not be modified by the User and is located in protected flash memory.
Incorporated http://www.iControl-Inc.com FCC Compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Incorporated http://www.iControl-Inc.com Figure 2 iSCAN™ FCC Label Location FCC Warnings: Modifications: Modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment under FCC Rules. Radio Frequency Exposure: Notes: 1) For mobile or fixed location transmitters the minimum separation distance is 20cm, even if calculators indicate the MPE distance is less.
Page 10
Incorporated http://www.iControl-Inc.com NCC 警語 - 減少電磁波影響,請妥適使用 (For Reducing RF Influence, Use Properly) - 為維護隱私權,請妥適使用 (For protect individual privacy, Use Properly) - 本器材須經專業工程人員安裝及設定,始得設置使用,且不得直接販售給一般消費者。 (This device must be installed by expert and will not be sold directly to the general public through retail store) - 低功率電波輻射性電機管理辦法...