Safety
Installation
Start-up
Read all instructions carefully before installation.
Use only the blower motor and circulating pump(s)
combinations marked on the Model Nameplate indicating
suitability for use in this model. Any other motors or pumps
cannot be substituted.
Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
and standards, including fire rated construction.
When cutting or drilling into a wall or ceiling, do not
damage electrical wiring or other concealed utilities (water
or gas lines, sewer lines, etc.).
Cooler motor, pump, cabinet and junction box must be
grounded in accordance with all local and national codes.
A ground wire must be used between the power supply
and the cooler.
Be sure that the cooler is connected to proper line voltage
stamped on the pump and blower (fan) motor specification
plate. NOTE: Improper voltage will void the pump and/or
motor warranties and may cause serious personal injury
or property damage.
Do not operate this blower (fan) motor with any solid-state
speed control device.
'
G
S
UIDE
C
M
ARE
ANUAL
Operation
Maintenance
Trouble Shooting
Congratulations: You have purchased a product of superior performance and design,
which will give the best service when properly installed, operated and maintained.
This guide will provide you with information needed to mount, operate, inspect, maintain,
and troubleshoot your evaporative air cooler.
The first section, Installation and Start-Up, gives details for installation. The second
section, Maintenance, contains operational and maintenance instructions , while
Troubleshooting includes information on commonly encountered problems.
INSTALLER: Please deliver this guide to owner.
WARNING -
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING.
Always disconnect electrical power to unit before working
on or servicing cooler. More than one disconnect switch
may be required to de-energize the equipment for
servicing.
Do not remove access panels while cooler is running, this
may cause the blower (fan) motor to overload and damage
the motor windings.
NOTE:
Do not locate unit near exhaust or vent pipes as odors or
fumes may be drawn into cooler.
Use of anode devices, chemical additives or treatments in this
cooler will void the warranty.
Your warranty does not cover shipping damage. Report all
shipping damage at once to dealer or carrier making the
delivery.
For future reference, record the model and serial numbers,
date and place of purchase of your evaporative cooler here:
Model #
Serial #
Date of Purchase:
Place of Purchase:
1-999-2467
Date: 1/14

Advertisement

Table of Contents
loading

Summary of Contents for Aerocool Trophy TD3800

  • Page 1 ’ WNER UIDE SE AND ANUAL DUCTED COOLER MODELS: TD3800, TD4801, TD4812, TD6801, TD6812 TH3800, TH4801, TH4812, TH6801, TH6812, TUP6801, TUP6812 For Customer Assistance CALL 1-800-325-6952 DO NOT RETURN TO PLACE OF PURCHASE! Congratulations: You have purchased a product of superior performance and design, which will give the best service when properly installed, operated and maintained.
  • Page 2 INTRODUCTION Location Your cooler may be a down (TD), horizontal (TH) or up (TUP) Your Trophy evaporative air cooler was thoroughly tested and discharge model. Down discharge coolers are designed for inspected before leaving the factory. This manual is your guide to installation on either flat or pitched roofs (see Fig.
  • Page 3: Installation

    Duct System Motor Installation Mount blower motor to the motor cradle using the motor straps as Air can be delivered over a distance to individual rooms or areas by shown. Position motor so that the vent holes in the motor case are means of a duct system.
  • Page 4: General Inspection

    Belt Tension Adjustment GENERAL INSPECTION CAUTION : Disconnect all electrical power to the cooler Initial Start-up or Annual Inspection and insure that belt is not rotating before adjusting belt tension. Do not adjust belt tension by changing diameter CAUTION: Disconnect all electrical power to the cooler of motor pulley.
  • Page 5: Maintenance Schedule

    Cleaning Water Pump & Hose MAINTENANCE SCHEDULE CAUTION: Disconnect all electrical power to the cooler Regular maintenance and periodic inspection is the key to long and before attempting to install, open, or service your cooler. successful service from your Trophy cooler. The cooler should receive More than one disconnect may be required to de-energize major servicing at least once a year, more often if conditions require the equipment for servicing.
  • Page 6: Troubleshooting Guide

    Changing Cooler Pads If necessary, replace with new pads, available from your dealer. Aspen, expanded paper or other types of evaporative CAUTION: Disconnect all electrical power to the cooler cooling pads will not work and will void your warranty. before attempting to install, open, or service your cooler. 3.
  • Page 7 A DEL ROPIETARO Í ANUAL DE SO Y UIDADO MODELOS de ENFRIADOR: TD3800, TD4801, TD4812, TD6801, TD6812 TH3800, TH4801, TH4812, TH6801, TH6812, TUP6801, TUP6812 Para Asistencia al Cliente LLAMAR 1-800-325-6952 NO REGRESARLO A LUGAR DE COMPRA! Felicitaciones: Usted acaba de comprar un producto de superior rendimiento y diseño, que la dará...
  • Page 8 Ubicación INTRODUCCIÓN Su enfriador ya sea modelo de descarga inferior (TD) o de descarga lateral (TH). Enfriadores de descarga lateral son diseñados para su Su enfriador fue detalladamente probado e inspeccionado antes de instalación en el costado del edifico, en techos con declive o planos salir de la fábrica.
  • Page 9: Instalación

    Sistema de Conducto Instalación de Motor El aire puede ser llevado a largas distancias para cuartos individuales Monte el motor de la turbina en su soporte usando las abrazaderas o áreas por medio de sistema de conductos. El sistema de conductos como se indica.
  • Page 10: Inspección General

    Ajuste de banda INSPECCIÓN GENERAL PRECAUCION: Desconecte toda la corriente eléctrica Lista de inspección de pre-comienzo o anual hacia el enfriador y asegúrese que la banda no este dando vueltas antes de ajustar la tensión. No ajuste la banda PRECAUCION: Desconecte toda la corriente eléctrica cambiando el diámetro de la polea del motor.
  • Page 11 Limpieza de la bomba y manguera LISTA DE MANTENIMIENTO PRECAUCION: Desconecte toda la corriente eléctrica Mantenimiento regular e inspecciones periódicas son la clave de un del enfriador antes de intentar instalar, abrir, o darle bueno y prolongado servicio de su Trophy enfriador. El enfriador debe servicio a su enfriador.
  • Page 12 Cambiando los filtros (aspen) e. Si es necesario, remplace con panales nuevos, disponibles en su distribuidor. Aspen, papel extendido u otros tipos de filtros PRECAUCION: Desconecte toda la corriente eléctrica del evaporativo no funcionan y anulan su garantía. enfriador antes de intentar instalar, abrir, o darle servicio a su 3.