Summary of Contents for Safety Technology International STI-6400 Exit Stopper
Page 1
STI-6400 Exit Stopper ® INSTRUCTION MANUAL Features: • Helps prevent both unauthorized exits and entries through emergency exit doors. • Easy to install. • Less expensive than heavy horizontal bar type units and practical for all emergency doors. • May be mounted on top, right, left or next to almost any door.
PECIFICATIONS Polycarbonate Enclosure: Dimensions 5.375” W x 5.375” H x 2 “ D (137mm x 137mm x 51mm) Flammability: UL94 V-2 Wall Thickness: 0.12 in (3.05mm) Electronics: STI-6400 - All Units 9 VDC Alkaline or 9V-24VDC wired Power Source Class II UL Listed transformer Horn Volume at 1 ft.
LARM EATURE ESCRIPTION • Volume Switch JP2 - Sets alarm volume to high 105 dB or low 95 dB. • Duration Switch JP3 and JP4 - Amount of time alarm sounds after trip. Arming resets at end of duration if door is closed. Alarm will not reset if in continuous mode; alarm sounds until battery is drained.
OUNTING PTIONS TYPICAL FLUSH MOUNT DOOR JAM INSTALLATION 19039 SCREW MAGNET MUST BE 6 x 1 1/4 in. INSTALLED OPPOSITE (2) PROVIDED RAISED RIB ON OUTER COVER. NOTE: 2 SPACERS MUST BE SPACERS - USE AS NECESSARY USED ON STEEL DOORS MAGNET 19018 ANCHOR (2) PROVIDED...
STI-6402 D OUBLE NSTALL OTES 1. Determine length needed for reed 06402 REED SWITCH (RS1) switch wires. STI provides 6 ft. which can be cut to desired length. TO KEY SWITCH 2. Connect first reed switch in RS1 and second in RS2 (Figure 7). (Refer to Figure 1 for additional details on page 4.) 3.