Takara Belmont Roller Ball AK-S23A Operating Manual

Takara Belmont Roller Ball AK-S23A Operating Manual

Far-infrared hair processor

Advertisement

Takara Belmont Far-Infrared Hair Processor
Mo del
A K− S 23 A
A K− S 23 A F
Operating Manual
Thank you for purchasing Takara Belmont product.
Please read through this manual carefully before
installing or using. These instructions provide important
information for correct usage of the product to avoid
personal injuries or property damages against you or
your clients.
This product is intended for the exclusive use in
hairdressing salons for their salon services, and must be
operated or handled by the hairdressers or by their staff
under the supervision of hairdressers.

Table of Contents

........................
..............................
...........................
........................
..............................
....................................
...........................
........................
Information
..............................
Third Version
July 2012
...
...............
...
1
1
1
..................
1
...
1
.....................
1
1
...
1
1
..................
2
...............
2
...............
2
Request No. 1A0929B0
1
5
6
6
7
7
9
0
1
3
5
5
6
6
7
9
0
1
3

Advertisement

Table of Contents
loading

Summary of Contents for Takara Belmont Roller Ball AK-S23A

  • Page 1: Table Of Contents

    ………………… … Lamp Indication during Operation and Inputs from Button Troubleshooting …………………… Thank you for purchasing Takara Belmont product. Care and Maintenance ……………… Please read through this manual carefully before installing or using. These instructions provide important Daily Inspection Procedure ……………...
  • Page 2: Safety Precautions (To Be Strictly Observed)

    These precautions are provided for the safe use of this product and to prevent personal injury and harm to users and third parties. Please follow all of the precautions shown here, as they contain important information related to safety. TAKARA BELMONT bears no responsibility for personal injury or harm caused to the user or third parties in the event that the “Safety Precautions”...
  • Page 3 Safety Precautions (To be strictly observed) WARNING Be sure to execute the daily check. Do not apply water to the product. Execute the daily check according to the “Daily Do not apply water to the main unit directly nor Inspection Procedure” described in this manual wipe them with a wet cloth.
  • Page 4 Safety Precautions (To be strictly observed) CAUTION Do not dry a towel on the rotation ring. Do not dry wet objects such as a wet towel on the rotation ring of the Roller Ball. Neglecting this caution may result in burning of the towel. Do not move the product while holding it at the ring or the guide bar.
  • Page 5 Safety Precautions (To be strictly observed) CAUTION Pay attention to the surrounding area when moving the product. Think of the physical condition of the customer. When the product is moved, the dryer arm will also The head of the customer will become warm due move as the product moves.
  • Page 6: Name Of Each Part

    Name of Each Part Top Cover Carrier Shaft Shaft Cover Control Panel Ring Cover Ring Heater Specification with Fan Upper Shaft Reflector Fuse Heater Guard Nape Guard Power Switch Guide Bar Grip Infrared Thermal Sensor Sensor Sheet...
  • Page 7: Location Of Warning Label

    Location of Warning Label MAY CAUSE BURNS DO NOT TOUCH THE HEATER GUARD MAY CAUSE THE DAMAGE ON THE HEATER DO NOT GIVE AN EXCESSIVE SHOCK TO THE RING Accessories Operating Manual: 1 copy...
  • Page 8: Control Panel

    Control Panel 3 Temperature Indicator 1 Display Panel 4 2 Temperature Buttons Time Setting Buttons Operation Mode 5 Selection Buttons Partial Heating 6 Buttons 8 9 Ring Rotation Button Mute Button 7 Start/Stop Button Fan Button (only for the specification with fan) Description of Buttons and Indications 1...
  • Page 9 Description of Buttons and Indications 5 Operation Mode Selection Buttons and Lamps Lamp - A mode can be selected by pressing the appropriate button. To customized the changed settings as the standard setting, keep pressing the button chosen for one second or longer. (See the section "Customized Settings"...
  • Page 10: Outline Of Modes

    Outline of Modes Description of Modes Mode Use the mode for the heating process of the hot double-process perms. Adjust the mode according to the hair condition, chemicals used, perming techniques, etc. (Hot double-process perms) Use the mode for the acceleration of the acidic hair dyes. Adjust the mode according to the hair condition, chemicals used, techniques, etc.
  • Page 11: Error Codes

    If the condition does not change after taking this action, contact the nearest dealer or Takara Belmont directly. indication will blink, alternately. The surface of the customer’s head Contact the nearest dealer or Takara Belmont directly.
  • Page 12: Setting

    Setting   Be sure to observe the correct use to make the maximum performance of the Roller Ball and to ensure comfortable use by the customer. Materials of Cap Used For the salon service using the hot double-process perming agents or the acidic hair dyes (acidic color), use the polyethylene cap. Since the polyethylene cap can transmit infrared rays, the infrared thermal sensor can correctly measure the hair temperature, thereby enabling correct temperature control.
  • Page 13 Setting   Alarm notifying misalignment of head position When the alarm sounds, ask the customer to (For the PERM, COLOR, and TREATMENT modes) return to the correct position. Misaligned position alarm! When the product is operated with the customer in the correct position, the infrared thermal sensor directly measures the customer's head temperature to control it to the preset temperature.
  • Page 14: Operating Procedures

    Operating Procedures   Set the Roller Ball in the correct position. If the unit is not set in the correct position, it will not work properly. (See page 11.) Turn on the power switch. When the power switch is turned on, all lamps will illuminate for one second, and then only the Time Setting Buttons operation mode lamps will blink, showing the state...
  • Page 15 Operating Procedures   Cooling [Changing the settings during operation] When the preset time has elapsed and the time Settings excluding mode selection can be changed during indication is zero (0), the cooling operation will be the operation. started. ※For the setting of ring rotation and stop, it can be changed only for manual mode.
  • Page 16: Rotation And Stopping Of Ring During Operation

    Rotation and Stopping of Ring during Operation   Only for the Manual Mode State of Ring Rotation Button during Operation Operation For regular use For use where the ring rotation is (Ring rotation button: ON) stopped under the manual mode (Ring Rotation button: OFF) The ring rotates.
  • Page 17: Customized Settings

    Customized Settings   1. Customizing Settings in Modes It is possible to adjust the initial settings in each mode as required. (customized settings) (The initial settings are displayed when the mode selection button is pressed.) The customized settings are stored in memory even after turning off the power. *During the operation or interrupted operation, the settings will not remain in memory.
  • Page 18: Troubleshooting

    Turn off the power switch, and contact the Is the fuse (located at the lower nearest dealer or Takara Belmont directly. side of the main unit) blown? Immediately stop using the product, Is the problem rectified when the...
  • Page 19 (See page 11.) nearest dealer or Takara Belmont directly. If the error code appears continuously even error Check if the customer's head position is not where the customer’s head set in the correct...
  • Page 20: Care And Maintenance

    Care and Maintenance   Splashing of water on the control panel or metal parts may result in product failure or rusting. Immediately dry the product with a soft cloth. Soft cloth The product should not be exposed to moisture and water. The plastic, plated, or painted parts should be wiped with a dry and soft cloth.
  • Page 21: Daily Inspection Procedure

    □Make sure that the dryer arm Move the product attached to the dryer arm If you note any problem, disconnect the and check the action. power plug and immediately contact the operates safely without any problem. nearest dealer or Takara Belmont directly.  ...
  • Page 22: Dimensions And Specifications

    Dimensions and Specifications Dimensions -mm- (194.5) 285.5 Specifications Model No. AK-S23A/AK-S23AF Weight 8.0kg Rotation clutch mechanism Safety device Power supply fuse AC110V 8.2A AC120V 9.0A Electrical requirements AC220V 3.4A 50/60Hz AC230V 3.5A AC240V 3.7A *Specifications are subject to change without notice.
  • Page 23 Dimensions and Specifications 1709 Dimensions 1602 -mm- 1546 (Operation Distance) * The above shows reference values when the lower end of the wall mount plate is installed at a height of 1900 mm from the floor surface. 1200 (45° )...
  • Page 24 TAKARA BELMONT CORPORATION 1-1, 2-Chome, Higashi-shinsaibashi,Chuo-ku,Osaka,Japan TEL : (06) 6213-5945 FAX : (06) 6212-3680 Printed in Japan...