Page 2
Make sure you comply with statutory and technical requirements when you install your SEguIn DuTERIEz firebox. Ask your SEguIn DuTERIEz Autopilot IHS™ is the product of a brand new patented technology that reseller for advice on assembling your firebox.
- Oxygen analyser test and calibration if necessary Symbol description - Test of the two motor dampers and calibration if necessary. IHS Logo The remote control indicates "Pass" if everything is correct, and "Failed" Appears as soon as you turn on the remote control, when there is a problem.
Page 4
Lighting the fire: Advanced menu The firebox is ready to light a fire and the flaps open. The remote control has a menu from which you This symbol appears by pressing the remote control can change the advanced settings. Press the twice in standby mode or in final combustion mode.
Page 5
Recommendations for lighting a Feeding the fire When the fire feeding alarm triggers, the firebox is ready for more wood. firebox fitted with the IHS system The remote control recommends how much wood to add. Small quantity of wood (700 - 1200 g) The so-called "reversed lighting"...
Page 6
- Open the damper: - When the complete load has ignited Open in the horizontal position - gradually close the damper: - Open the ashbox air slide: Flap closed = control in the vertical position Aire slide pushed to the left/to the right - Press the remote control twice: The "matchbox"...
Reassemble the unit after inspection and cleaning Window Do not alter the air passages without first consulting cheminées SEGuIn Air passage n° 3: Approx. 1 mm gap CAutIon: It is recommended to carry out this cleaning operation twice...
Fault detection When the remote control displays a fault The remote control can trigger 2 types of alarm. Servicing alarms and safety alarms. Safety alarms are more serious than servicing alarms. The following diagram indicates the meaning of the alarms that are displayed on the remote control. Servicing alarms on the remote control You can continue using the firebox but the fault must be found because the firebox requires technical servicing.
Page 9
** In the event of fault n° 1-2-3 and 13, proceed as follows: 4 - Remove the top cover PROCEDuRE TO REPLACE THE SEnSOR OR SEnSORS 1 - Remove the firebox Airbox support plate (4 hexagonal screws) temperature sensor oxygen sensor 5 - Raise the cable or cables to the top 6 - unscrew the sensor or sensors 7 - Replace the sensors...
Need help?
Do you have a question about the AutopilotIHS and is the answer not in the manual?
Questions and answers