Table of Contents

Advertisement

Quick Links

ClosetAir Installation
Manual
geistglobal.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ClosetAir and is the answer not in the manual?

Questions and answers

Summary of Contents for Geist cool ClosetAir

  • Page 1 ClosetAir Installation Manual geistglobal.com...
  • Page 2: Table Of Contents

    Two Installation Options ........................... 17 Mounting Requirements ........................... 18 Initial Setup ........................... 20 Data Form ats ................................20 Accessing Web Server ................................20 Window s ................................20 ................................23 Chapter 3 - Installation GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 3: Table Of Contents

    General Safety ................................51 Live Circuits Safety ................................51 Equipm ent Grounding ................................51 Electrostatic Discharge ................................52 Explosive Environm ent ................................52 Servicing and Adjustm ents ................................52 Repairs and Modifications ................................52 GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 4 ClosetAir Installation Manual GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 5: Introduction

    Section 1502 of the Dodd-Frank Act which was passed by the US Congress in 2010 requires certain companies to annually disclose their use of conflict minerals. Conflict minerals covered under this act include tantalum, tin, tungsten, and gold. GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 6 Nor shall Geist, a division of PCE, Inc., and its affiliates be liable for any damages, inclusive of loss of profits or data, arising from the use of or in connection with this document. GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 7 © 2017 - Geist, a division of PCE, Inc. All Rights Reserved Rev 06/30/2017 GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 8: About This Manual

    Audience Profile This document is intended for use by authorized technicians experienced with same of similar product types and for personnel requiring guidance for equipment installation, operation, maintenance, and support. GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 9: On-Line Documentation

    Version control: V(ersion) Platform #, Major #, Minor # Hardware Product Classification o Power Distribution Unit  Basic  Monitored only  Switched only  Monitored + Switched o Environmental Monitoring o Cooling o Data Center Infrastructure Management (DCIM) GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 10 ClosetAir Installation Manual Figure 1 Overlay Symbology Guide The chart above depicts the symbols used on Geist overlays. GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 11: Safety

    INDICATES A POTENTIAL HAZARDOUS SITUATION WHICH, IF NOT AVOIDED, COULD RESULT IN PRODUCT DAMAGE AND MINOR TO MODERATE INJURY. NOTE Provides useful information that is beneficial for operation and usage of this product. GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 12: Figures

    Name and/or Title goes here Column 1 Column 2 Column 3 Column 4 Column 5 Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 13: Chapter 1 - Product Specifications

    Minimum Maximum Operating 95% (non-condensing) Storage 95% (non-condensing) Elevation Table 1-3 Elevation Limits Minimum Maximum Operating 0 m (0 ft) 2,000 m (6,561 ft) Storage 0 m (0 ft) 15,240 m (50,000 ft) GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 14: Electrical

    Electrical Electrical product characteristics an performance are defined below. Also please see the product nameplate for additional rating limits. Electrical Specifications The ClosetAir RAC10 operates with power inputs as shown in the following table. Table 1-4 Electrical Specs Input Specifications...
  • Page 15: Federal Communications Commission (Fcc)

    An independent U.S. government agency overseen by Congress, the commission is the United States' primary authority for communications laws, regulation and technological innovation. The FCC standards specific to this equipment are: FCC Part 15 Class A GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 16: Chapter 2 - Pre-Installation

    2. Plug RAC10 into appropriately rated and protected branch circuit receptacle. Service and Maintenance: No service or maintenance is required. Do not attempt to open the RAC10 or you may void the warranty. No serviceable parts inside. GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 17: Two Installation Options

    Chapter 2 - Pre-Installation Two Installation Options Figure 2-1 Installation Options Wall or ceiling mount for automated heat exhaust and critical monitoring / alerts. GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 18: Mounting Requirements

    3. Supplying power receptacle must be below drop ceiling to keep power cord out of plenum space. 4. Optional RAC-D002 duct kit may be used for interfacing to existing duct work. Figure 2-2 Drop Ceiling Mount Option GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 19 Chapter 2 - Pre-Installation Wall Mount 1. Mount to wood studs, spaced 16” apart. 2. Must use 2” length, #10 wood screws into studs as shown in Figure #2. Figure 2-3 Wall Mount Option GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 20: Initial Setup

    Click the Start button, then choose Control Panel >> Adjust Your Computer's Settings >> View Network Status and Tasks >> Change Adapter Settings. (Alternatively, on some Windows 7 machines, this may be Start, then Settings >> Control Panel >> Network and Sharing Center >> Change Adapter Settings.) GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 21 Internet Protocol Properties window. If you see more than one TCP/IP entry, as in the example above, the computer may be configured for IPv6 support as well as IPv4; make sure to select the entry for the IPv4 protocol. GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 22 IP address, simply repeat the steps above, and change the computer's Ethernet NIC card settings back to the ones you wrote down prior to changing them, to restore its normal network and internet settings. GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 23: Mac

    IP address, simply repeat the steps above, and change the computer's Ethernet NIC card settings back to the ones you wrote down prior to changing them, to restore its normal network and internet settings. GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 24: Chapter 3 - Installation

    Fan Controller gives useful trend analysis data that allows users to view changes and draw useful conclusions about what is happening over time in the monitored environment. Figure 3-1 Sensors Page GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 25: Items Displayed On Sensors Page

    This value will read 0 °C or 32 °F until and external temperature sensor is connected. · Capacity: Percent, from 30-100 of maximum fan speed. 0 may be selected to disable the fans if needed. GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 26: Alarms

    Alarm options include time tripped before notification, a repeat cycle, Email and SNMP Trap. There is also a provision to notify if a sensor is unplugged. Figure 3-3 Alarms Page GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 27: Alarm Types

    Alarms can be added for set point, fan speed, and internal or external temperature sensors displayed on the Alarms page. An alarm is added by pressing the “Add New Alarm Button” and selecting the sensor value to be monitored from a drop down menu. GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 28: Alarm Notifications

    The RAC unit is capable of any combination of the above alarms at once. Alarm type combinations are selected per alarm via the check boxes which are displayed for each alarm on the Alarms page. GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 29: Thresholds

    XML: Extensible Markup Language. Presents data in a structured tree for use with automated · scripts and monitoring systems. MIB: Management Information Base. Downloads the MIB for use with SNMP monitoring tools. · GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 30: Logging

    The number of selected sensors determines the maximum data logging time span. This period is calculated and displayed on the Logging page. The oldest data will be deleted when the onboard memory fills up in order to make room for new data. GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 31: Display

    The default interface displays a vertical menu bar to the left of the main window, while the classic interface displays a horizontal menu bar across the top of the screen. Figure 3-7 Display Page GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 32: Config

    · HTTP/HTTPS Server Port: Changes the TCP port that each server listens on. DNS Servers: Allows the unit to resolve host names for Email, NTP and SNMP servers as well · as cameras. GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 33: Configuration Network Tab

    Chapter 3 - Installation Configuration Network Tab The user can enter and update the network settings on the Network tab of the Configuration page. Figure 3-8 Configuration Network Tab GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 34: Configuration Monitoring Tab

    Configuration Monitoring Tab The user can enter and update the email alert, SNMP, and camera settings on the Monitoring tab of the Configuration page. See Unit Configuration section for details. Figure 3-9 Configuration Monitor Tab GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 35: Configuration Diagnostics Tab

    Chapter 3 - Installation Configuration Diagnostics Tab The user can update the Syslog settings on the Diagnostics tab of the Configuration page. Figure 3-10 Configuration Diagnostics Tab GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 36: Configuration Event Log Tab

    ClosetAir Installation Manual Configuration Event Log Tab The user can view the Event Log and update the Memory Syslog settings on the Event Log tab of the Configuration page. Figure 3-11 Configuration Event Log Tab GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 37: Configuration Admin Tab

    Chapter 3 - Installation Configuration Admin Tab The user can set the system clock on this tab. Additionally the user can set administrator and account passwords. Figure 3-12 Configuration Admin Tab GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 38 ClosetAir Installation Manual GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 39: Time And Date

    The time, date, IP address and friendly name of the unit are displayed in the top of each web page. NOTE The time and date are not adjusted for daylight savings time. Setting the time zone offset forward and backward an hour will cause a gap or overwriting of logs, respectively GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 40: Email

    Monitoring tab of the Configuration page. NOTE The unit cannot receive emails, the POP3 server is used strictly for authentication and is not required when using None or ESMTP. GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 41: Status Reports

    48 hours. Email addresses are selected when the report is created by checking the corresponding email destination box. Allowing the cursor to hover over an email destination box will display the email address that the box is associated with. Figure 3-15 Email Reports Page GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 42: Accounts And Passwords

    IP address and passwords given in the Default IP Address section. To generate a temporary recovery password to access the unit, contact customer service from a location where the unit can be accessed via the internet. GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 43: Snmp

    Monitoring tab of the Configuration page. Figure 3-17 SNMP Configuration Page The default community string is “public” and the MIB is downloadable via a link at the top of the unit’s web page. GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 44: Camera Configuration

    “Cameras” section of the Monitoring tab on the Configuration page. The unit will present a linked snapshot from each camera on the Sensors page. Figure 3-18 Camera Configuration Page NOTE Each camera must be set to allow anonymous access to enable this feature. GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 45: Telnet

    Information entered in the “Admin Info” section of the Admin tab of the Configuration page will show up at the bottom of the unit’s web interface. Figure 3-19 Admin Configuration Page Figure 3-20 Admin Information Display on Configuration Page GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 46: Control

    In addition, the Control page allows the user to assign friendly names to any external temperature sensors attached to the RAC10. Figure 3-21 Control Page GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 47: Initial Set Point Configuration

    · fan speed. Fan Capacity: Tells the RAC10 to use the manual set point entered in the box on the Control · page for a continuous fan capacity. Figure 3-22 Set Point Configuration GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 48: Accessories

    The sensors use a serial communication protocol and are subject to network signaling constraints dependent on shielding, environmental noise, and length of wire. Typical installations allow runs of up to 600 feet of sensor wire. GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 49: Ip-Addressable Network Cameras

    Camera model and IP address are entered on the Monitoring tab of the Configuration page. Figure 3-24 Camera Configuration Page NOTE Some cameras require additional software downloads to display live video in a web browser. GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 50: Chapter 4 - Final Checkout

    From within the UK 0845 026 3853 · · From abroad +44 845 026 3853 Asia English +1 888 630 4445 (US number) · · Chinese +86 755 8663 9505 Or contact your distributor. GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 51: Product-Specific Safety Notices

    The input power cable must be either plugged into an industry electrical code compatible receptacle or wired directly into an electrical code compatible interface. The equipment earth ground wire (typically green) must be firmly connected to the GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 52: Electrostatic Discharge

    Because of the danger of electrocution and/or severe health hazard, do not install substitute parts or preform any unauthorized modifications of this equipment. It is best to contact Geist for Warranty and Repair Service to ensure that safety features are maintained. GM1159 ClosetAir Installation Manual © 2017 Geist...
  • Page 53 Back Cover Thank You For Purchasing Geist...

Table of Contents