CETC AV3680A Quick Start Manual

Handheld cable & antenna tester

Advertisement

Quick Links

AV3680A
Handheld Cable & Antenna
Tester
Quick Start Guide
st
THE 41
INSTITUTE OF
CHINA ELECTRONICS TECHNOLOGY GROUP CORPORATION

Advertisement

Table of Contents
loading

Summary of Contents for CETC AV3680A

  • Page 1 AV3680A Handheld Cable & Antenna Tester Quick Start Guide THE 41 INSTITUTE OF CHINA ELECTRONICS TECHNOLOGY GROUP CORPORATION...
  • Page 2 Antenna Tester developed denotes content and the terms in this and produced by the 41 hazard. It calls attention to a Guide belongs to the 41st Institute of CETC. As a high- particular operating Institute of CETC. grade, precision procedure, method, or other...
  • Page 3: Table Of Contents

    Quick Start Guide for AV3680A Handheld Cable &Antenna Tester Contents Chapter 1 Manual Overview ................. 1 Chapter 2 Ready for Use ..................2 2.1 Pre-operation Preparation ................. 2 2.2 Startup and utilization ................4 2.3 Front Panel ....................4 2.4 Operating interface ..................6 2.5 Top Interface .....................
  • Page 4: Chapter 1 Manual Overview

    It introduces the calibration of AV3680A in detail, and describes operating steps for basic measurement formats of AV3680A and gives a brief description on techniques used in the test, through test cases such as cable testing, antenna testing, etc. By reading this chapter, you can use AV3680A to finish some typical DUT test by yourself.
  • Page 5: Chapter 2 Ready For Use

    2.1.1 Environmental Requirements To ensure the service life and validity and accuracy of AV3680A, please conduct testing under the following conditions: 1. Temperature range: Storage temperature range: -40℃ ~ +70℃; operating temperature range: -10℃ ~ +50℃...
  • Page 6 3. Powered by built-in battery AV3680A can be powered by rechargeable lithium-ion batteries. If left unused for a long time, the battery will self discharge, so it must first charge the battery before using it again. Refer to Section 2.6 for battery usage details.
  • Page 7: Startup And Utilization

    Warning menu name. 2.3 Front Panel This Section provides a detailed introduction of the front panel of AV3680A. Figure 2.1 is the front panel of AV3680A. Figure 2.1 Front panel of AV3680A Handheld Cable & Antenna Tester The features of common keys are described as below:...
  • Page 8 Quick Start Guide for AV3680A Handled Cable & Antenna Tester 【FREQ/DIST】: used for measurement parameter settings such as frequency parameter, signal standard, distance parameter and velocity factor etc. 【SWEEP/SET】: used for measurement parameter settings such as trigger mode, scan mode, scan time, scan points and average / bandwidth etc.
  • Page 9: Operating Interface

    Quick Start Guide for AV3680A Handled Cable & Antenna Tester 2.4 Operating interface AV3680A is provided with a 7-inch HB TFT true color LED with the function of touch screen and supports soft-key operations of applications through touch screen. The operating interface is as shown in Figure 2.2.AV3680A provides different interfaces with different color contrast corresponding to different testing...
  • Page 10: Battery

    Buying stand-by batteries of the same model with the original one is recommended if long-time field test is performed. The mounting or replacement of the battery of AV3680A is easily performed as shown in Figure 2.1.
  • Page 11 Quick Start Guide for AV3680A Handled Cable & Antenna Tester Mount/ Pull out the battery Pull down Open battery cover battery cover Push up battery cover Close battery cover Figure 2.1 Battery Mounting or Replacement In addition, for those dead batteries, charging time in OFF state is about 4 hours.
  • Page 12: Chapter 3 Typical Application

    Quick Start Guide for AV3680A Handled Cable & Antenna Tester Chapter 3 Typical Application AV3680A offers many measurement formats, and this Chapter will make a detailed instruction on operation steps of several basic measurement formats by three test cases. 3.1 Calibration To ensure accuracy of test results, the instrument needs to be calibrated before test to eliminate the system errors.
  • Page 13 Quick Start Guide for AV3680A Handled Cable & Antenna Tester Specific mechanical calibration procedure is as follows: ➢ Connect the OPEN to the test port and select the [Open] menu. At this time, the screen will automatically prompt “[开路器/OPEN]测量中……”. When the [Open] menu becomes into [Open], it indicates the completion of the OPEN calibration.
  • Page 14: Cable Test

    Figure 3.6 Connection Type for Return Loss/VSWR Measurement AV3680A mainly tests RF cable. Take the cable with length of 25m, radio frequency of 2.1GHz and VSWR of 1.05 as an example, this part makes a detailed instruction on test steps of return loss (Measurement steps of return loss and VSWR test are the same, therefore, it only takes return loss measurement as example here).
  • Page 15 Quick Start Guide for AV3680A Handled Cable & Antenna Tester Figure 3.7 Selection of Measurement Format 3. Press【FREQ/DIST】to enter the frequency menu; select [Start Freq] menu, then use the numeric keys, knob or arrow keys to input the start frequency value and select the corresponding unit menu to complete the input;...
  • Page 16 Quick Start Guide for AV3680A Handled Cable & Antenna Tester Figure 3.9 Return Loss and SWVR Test Diagram at 2,100MHz Return loss or VSWR is the matching degree of DUT at each frequency point in the whole frequency band. Sweep span can be specifically set according to CAUTION operating frequency of the measured cable or DUT during measurement.
  • Page 17 Quick Start Guide for AV3680A Handled Cable & Antenna Tester Press 【FREQ/DIST】to enter the frequency menu; select [Start Freq] menu, then use the numeric keys, knob or arrow keys to input the start frequency value and select the corresponding unit menu to complete the input;...
  • Page 18 Fault Point Figure 3.13 DTF Measurement Connections AV3680A provides two measurement formats including DTF return loss and DTF VSWR. As for their difference, we will not explain here again for it is similar to the difference between return loss and VSWR.
  • Page 19 Quick Start Guide for AV3680A Handled Cable & Antenna Tester Figure 3.15 Start Frequency & Stop Frequency Set 5. Press 【SWEEP/SET】 to enter sweep/set menu; select [Sweep Point] to set the required sweep point, which is set to 401 here, as shown in Figure 3.16.
  • Page 20 Quick Start Guide for AV3680A Handled Cable & Antenna Tester Figure 3.17 Start Distance & Stop Distance Set 8. According to Section 3.1 in this Chapter, calibrate port 1 of Tester; 9. Select [Velo Factor] menu to set velocity factor of DUT, as shown in Figure 3.18. Velocity factor, which is the transmission speed and light speed of electromagnetic wave in the cable, is between 0~1.
  • Page 21 Quick Start Guide for AV3680A Handled Cable & Antenna Tester Figure 3.19 Cable Loss Set Velocity factor and cable loss are inherent parameters of cable, if any further questions, please check the cable instructions or consult the CAUTION cable manufacturer.
  • Page 22: Antenna Test

    Figure 3.21 Measurement on Length of Cable 3.3 Antenna Test AV3680A can test the return loss/VSWR of general passive receiving antenna. This part will introduce the measurement process of passive antenna by taking terminal antennaTZD-P021Z05-195 as an example. Terminal antenna TZD-P021Z05-195 is kind of receiving antenna with frequency of 2,100MHz, whose standing wave is minimum at 2,100MHz in theory.
  • Page 23: Universal Devices And Parts Test

    Figure 3.23 VSWR Test of Terminal Antenna TZD-P021Z05-195 3.4 Universal Devices and Parts Test Addition to cable and antenna test, AV3680A can also be used for testing the attenuation, cable connectors, cable joints, etc. This part will measure the return loss of 10dB attenuation, as an example, with operations as follows: 1.
  • Page 24: Test Skills

    As there have given a detailed description to the test steps for several test formats, this part will make a brief introduction on some common skills used in the measurement process. 1. Amplitude: AV3680A provides three ways for amplitude adjustment: First, through the top and bottom adjustment; Second, through automatic ratio adjustment; Third, through the adjustment on reference value, location and ratio.
  • Page 25 Figure 3.27 Return Loss Curve after Automatic Ratio Adjustment 2. Limit line: Users have their own eligibility criteria in batch test. In this regard, AV3680A provides 【Limit】 function for the setting of limit line, making it easier to test products. Thus, when large quantities of products need to be tested, it only needs to replace DUT and observe limit line to judge whether the product is qualified or not.
  • Page 26 5. Cable Model: It has given detailed steps for setting velocity factor and cable loss in DTF test. To make it easier to test and set parameters, AV3680A offers a series of common cable models for user’s recall. Users can directly use[Cable Model] menu in the menu bar of 【FREQ/DIST】to enter the interface for cable model selection.
  • Page 27 The more the sweep points are, the longer the measured maximum distance will be. In terms of cable loss, nominal value of effective directionality of AV3680A is equal to or more than 42dB. If the reflected signal energy is less than the effective directionality, the valid test result is not available.
  • Page 28: Chapter 4 Ask For Help

    4.1 Basic check  If any problem occurs in the AV3680A you are using. You can check them yourself in accordance with the following guidance. If the problem remains, please contact us. ...
  • Page 29: Return-To Factory Repairing Method

    4.3 Repair Method When your problems with AV3680A appear difficult to solve, you can contact us by phone or fax. If you confirm that the instrument needs to be repaired, please follow the steps below to package the instrument: 1) Write a paper document describing the instrument failure and put it in a packing case with the Tester;...
  • Page 30: Appendix I: Technical Indicators

    Quick Start Guide for AV3680A Handled Cable & Antenna Tester Appendix I: Technical Indicators The technical indicators of AV3680A have been strictly tested when leaving the factory. Users can also verify the testing in accordance with the technical indicators provided in this manual. The major technical indicators of AV3680A are as shown in the table below.
  • Page 31: Appendix Ii: Accessories / Options List

    Quick Start Guide for AV3680A Handled Cable & Antenna Tester Appendix II: Accessories / Options List Table 2 Accessories / Options List of AV3680A Handheld Cable & Antenna Tester Home Accessories/ Options No. Accessories/ Options 1 power cord 1 AC-DC adapter...

Table of Contents