3.93 and higher. 2-Stage Cool Mode Basic Description: In 2-Stage cooling (C2) mode the TC-1 uses a single temperature probe to monitor glycol temperature and, based on stage 1 and stage 2 set points, engages stage 1 and stage 2 relays whenever glycol temperature is above each stage's respective set point.
2-stage thermostat operation. For complete controller installation details, please see TC-1 Installation Guide and related advisories. Power the TC-1 via appropriate mains voltage and wire per TC-1 Installation Instructions. Attached a TP-1 temperature probe to the controller's ...
Page 4
Press the PGM button to advance to 'dCH' (dual-zone cool/heat) and turn this setting 'On' via the UP or DOWN button...
Page 5
Only COOL and HEAT modes are affected when 'dCH' is set to 'On'. Also, the following parameters are ignored by the thermostat when 'dCH' is set to 'On': CP, HP and Hr. Please see TC-1 User's Guide for more information about these parameters.
Page 6
Adjusting ZONE1 Set Point (SP1) Press / release the PGM button to advance to the 'SP1' entry screen (as indicated in the TEMPERATURE display window) Press the UP/DOWN buttons to adjust SP1 to the desired value (as shown in the SETPOINT display window) Adjusting ZONE2 Set Point (SP2) Press / release the PGM button to advance to the...
Page 7
Displaying Zone Temperatures and Set Points When PROBE 1 is selected, temperature and set point for ZONE1 are displayed in the TEMPERATURE and SETPOINT windows, respectively. Likewise, when PROBE 2 is selected, temperature and set point for the ZONE2 are displayed in the TEMPERATURE and SETPOINT windows, respectively.