Page 1
AGURO Manual for installation, operation and maintenance GB_2016_30 GB_2016_31 It was tested according to/complies with norms: • EN 14 785:2007 • 15a B-VG • Din + • BIm SchV 2...
Dear customer, We thank you that you have bought a AGURO pellet stove, thus having shown your confidence in VIADRUS brand. Your new stove was manufactured in a company that is a holder of ISO 9001:2000 certification. Before installation and commissioning, please carefully acquaintance with the instruction manual for your new pellet stove.
Page 4
Legend: Protective grate 15. Stone Reservoir 16. Steel heat-exchanger Auger 17. Insulation Auger motor 18. Ceramic insulation Control unit 19. Rear cladding Manostat 20. Cast-iron burner bowl Flue exhauster 21. Heating chamber Cast-iron door frame 22. Cast-iron heat-exchanger Display 23. Cleaning cover 10.
Fig. №. 2 Main dimensions Transportation and storage Transportation The pellet stove has to be only transported in the vertical position, in the original package and with properly fixation against movement and falling. Transportation has to be performed in close space in order to avoid damage from atmospheric conditions.
Before installation of pellet stoves it is necessary to carry out revision of the breast, into which the stove has to be connected, including design and assessment of the flue channel, which has to provide safety exhaust of flue gases from the connected stove.
Connection of the pellet stove to the chimney Before commissioning the pellet stove, check and testing of the flue channel has to be performed even before closing the flue channel by the sheathing of the heat-air chamber. These activities may be only performed by a qualified person, for example, a chimney-sweeper company.
Wrong operation and insufficient combustion of fuel brings to a damage of the product. The control of the AGURO pellet stove is very easy. Control elements of the pellet stove are displayed in Fig. 4 Navigation in menu „UP“, increase the value Navigation in menu „DOWN“, decrease the...
• Put ash into inflammable vessels with a cover! • The consumer mustn’t be used for combustion of waste, rubbish; and no liquid fuels can be used in any combination! Use only recommended fuels. • In case of occurrence of a fire of deposits in the chimney, extinguish quickly the fire in the stove by a dry-power extinguisher or by sand, remove all flammable material situated near the stove and the chimney body.
The first commissioning At the first kindling, because of burning-in of the surface painting of the pellet stove, it is necessary to ventilate constantly and supply enough quantity of fresh air to the room! • Before the first commissioning, it is necessary to remove labels and withdraw parts of accessories from the ash-pan or from the combustion chamber;...
Page 11
Screen 1 Screen 2 Information Information Exhaust T [°C] Ignition [nr] Room T [°C] Prod. Code 494-6000 Air Flux Fan Speed [rpm] Work Time [h] MENU 2 – MENU CUSTOMIZATION - Press the button – to display the screen for changing of user parameters. Screen 1 Screen 2 Menu Customization...
Page 12
MENU 2.2 – HEATING MANAGEMENT Manual setting of the room thermostat temperature Heating Management Room Thermostat << MENU 2.2.1 – ROOM THERMOSTAT Setting of the temperature value on the room thermostat Room Thermostat Max: 40 Set: Min: MENU 2.3 – REMOTE CONTROL Selection of using of the stove remote control.
Page 13
MENU 2.4.2.1 – DAILY Selection of days in the daily mode – from Mon to Sun (separately for each day) Daily Monday Tuesday << Wendesday Thursday Friday MENU 2.4.2.1.1 Setting of times of the stove operation from – to for separate days of the mode (3 modes/day) Daily Monday...
Page 14
MENU 3 - MENU SETTINGS Press the button for at least 3 sec. to set user parameters Menu Settings Keyboard Settings << Keyboard Menu System Menu MENU 3.1 – KEYBOARD SETTINGS Date, time and language settings. Keyboard Settings Time and Date <<...
MENU 3.2.4 – SET CONTRAST Setting of text contrast on the display Set Contrast MENU 3.2.5 – SET MIN LIGHT – Setting of the minimum time of lighting of the display at non-active mode of the display. Keyboard Menu Learn Menu Keyboard Address Node List Set Contrast...
Stove first ignition and shutdown procedure 1. Please sure that the equipment is reliably connected to a chimney. 2. Pour pellets into the reservoir so that the pellet state sensor (situated on the left side of the reservoir) was under the pellets level. The reservoir capacity is approximately 35 kg of pellets. 3.
Pellet supply and exhaust fan rpm adjustment mode Each pellet stove is placed in different environment and in different geographic conditions, and that is both atmospheric and pressure ones. Somewhere the stove seems is combusting too “quickly”, and, on the contrary, somewhere too “slow”, although the system is automatically controlled.
Pellet stove maintenance and cleaning Equipment, which is not maintained according to our instructions, mustn’t be operated. In case of non-observance of the specified instructions, the warranties granted by the manufacturer would not be accepted. Carry out maintenance and cleaning of the stove essentially when the heating chamber is cold.
Clean-up of the heating chamber As soon as you find remnants of ash in the heating chamber, it is necessary to clean-up it (see chapter 7). The excessive ash quantity causes accumulation of pellets in the burner bowl and prevents access of needed combustion air to the pellets. The result could be the bad pellets combustion, clogging the glowing ignition plug or general bad function of the pellet stove.
The spaces to be cleaned: Upper flue heat-exchanger: Demount the upper cover. Loosen up 4 pcs of screws of the cleaning cover of the heat-exchanger by means of a mounting spanner No. 10 (it is a part of supply) and demount the cleaning cover. Sweep the heat-exchanger walls by a hand-brush and vacuum them by an ash vacuum-cleaner.
Possible causes of operation problems and their removal In case of problems that you cannot remove by yourselves, contact the supplier of the stove or a chimney-sweeper. PROBLÉM CAUSE SOLUTION Functionless display equipment • Switch-on the switch situated on the rear side to the powered position „1“...
This is valid for Czech Republic: All information regarding warranty for the product, cancelling of the warranty and possibility of reclaiming are specified on web-site: www.viadrus.cz This is valid for foreign countries: For all information regarding warranty for the product, cancelling of the warranty and possibility of reclaiming, please contact your seller.
Need help?
Do you have a question about the aguro and is the answer not in the manual?