Advertisement

Quick Links

C-PANEL
User Manual
Version:V1.00
1
www.jps.com.tw

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C PANEL and is the answer not in the manual?

Questions and answers

Summary of Contents for JPS C PANEL

  • Page 1 C-PANEL User Manual Version:V1.00 www.jps.com.tw...
  • Page 2: Table Of Contents

    2.3.3 Use th fly wheel function in the monitor mode ..............6 2.3.4 Use fly wheel and up/down keys to edit data ................6 Parameter Mode (Select,Read,Edit,Write) ................7 2.4.1 Select the parameter to edit or read..................8 Alarm Mode ............................9 (RESET) ...............................9 C-Panel SIZE ..............................10 www.jps.com.tw...
  • Page 3: C-Panel Description

    Monitor Mode 5-digital Numerical Displahy N, Hz ,A, V Negative Symbol data type indicator DI Status Bar Status of DI16 Status of DI1 The DI Status Bar shows the on/off status of DI1 ~ DI16 for real time. 。 www.jps.com.tw...
  • Page 4: The Start Up Message Of Panel

    (1). After Start up the display will show the panel’s software version firstly. P8b10 (the sample shows the version (2). Then the display changes the message to show company’s logo. -JPS- (the sample shows (3). Then the display changes the message to show the fitting motor type. Induc...
  • Page 5: C-Panel Opearation Guide

    In order to operate the run and stop function on the control panel, the condition list below should be satisfied:  Pr.065=0 FWD terminal function: no function.  Pr.068=73 Set the virtual input function: FWD function.  Pr.059=1 Control panel RUN / STOP function switch: enable. www.jps.com.tw...
  • Page 6: Use Th Fly Wheel Function In The Monitor Mode

    Using up/down keys to change the value press to change the value. Bothe of these two ways can be used to change the value.  Write twice within 0.5sec, the value will be written into memory. Press www.jps.com.tw...
  • Page 7: Parameter Mode (Select,Read,Edit,Write)

    Enter edit mode to change the value, if you wish. Write down the value into the parameter and save in memory. Exit from edit mode to select another parameter, or exit to the top level to change to another operation mode. www.jps.com.tw...
  • Page 8: Select The Parameter To Edit Or Read

    Edit parameter value Write down the parameter value The proceedures of editing and writing the parameter value are same with the proceedure that are introduced in paragraph 02.3.4 . Return Press to return to previous mode sequentially. www.jps.com.tw...
  • Page 9: Alarm Mode

    ** After power on or reset, all alarm record will be shift by the sequence A0A1A2A3, and the record A0 will be refresh by present status. (RESET) mode  Press Twice within 0.5sec. This procedure will reset the driver and panel itself, and the effect like power-on restart. www.jps.com.tw...
  • Page 10: C-Panel Size

    C-Panel SIZE 面板尺寸 開孔建議 C- PANEL (PANEL SIZE) (hole size recommendation) (Unit:mm) www.jps.com.tw...

Table of Contents