U S E R M A N U A L The Dyna-Form Mercury Advance is a pressure relieving mattress suitable for use with patients at VERY HIGH RISK of pressure ulcer damage. Offering high levels of patient comfort, this unique system has the facility to “step up” to that of a dynamic mattress when clinically required.
A and B cells which are filled and emptied in sequence. In Static Mode, the mattress attains the pressure reducing properties of the Dyna-Form Mercury static foam mattress (details available on request), whilst in Alternating Mode the mattress is able to offer similar properties to a pressure relieving dynamic system.
Page 5
U S E R M A N U A L LED Mode Settings This symbol when illuminated (The green indicator light) is used to indicate that the equipment is on or ready for use. When a patient requires a true dynamic function or indeed more pressure in the cells, as they may be uncomfortable or feel as though the support surface is too soft or unstable, then please Power On / Off select a “High”...
D Y N A - F O R M M E R C U R Y A D V A N C E 3. Troubleshooting Warning / Fault Cause Solution Control Unit does The Control 1. Check the Control Unit is connected to mains power outlet with the correct voltage. Unit may not be not operate;...
4.1 Mattress (This is the applied part type BF) Place the Dyna-Form Mercury Advance Mattress directly on to the bed platform ensuring that the Blue multi-stretch waterproof cover is on top and that the umbilical hose is located at the left- hand corner at the foot end of the bed.
Control Unit off. 5.3 Troubleshooting For assistance (if needed) in setting up, using or maintaining the Mercury Advance System, or to report unexpected operation or events, please contact Direct Healthcare Services on the contact details on the reverse of this manual.
Do wash hands before commencing the cleaning process. 8.4.1 Warning Wear appropriate protective clothing such as gloves, apron Ensure the Mercury Advance System is not exposed to: and a mask. 1. Excessive heat sources e.g. fires, radiators etc. Ensure all work surfaces are cleaned before and after contact 2.
LIMITATION Operational Altitude ..........≤ 2000m Control Unit Symbols 10.2 Exposure Exposure to direct sunlight, dust, lint and general debris is not considered to be an issue with the Mercury Advance System. SERVICE REFER TO DO NOT DISPOSE OF REQUIRED USER MANUAL WITH HOUSEHOLD WASTE.
• Do not connect to any other medical device or equipment. • Correct fuse rating MUST be used. Failure to do so could result The Mercury Advance System should not be used for patients with in the risk of a fire.
Page 12
D Y N A - F O R M M E R C U R Y A D V A N C E EMI/EMC Statement and Manufacturer’s Declaration This equipment has been tested and found to comply with the limits of EN 60601-1-2 2007. These limits are designed to provide reasonable protection against harmful interference in both a medical and residential environment.
Need help?
Do you have a question about the Mercury Advance and is the answer not in the manual?
Questions and answers