Quick Links

Pro
Power SB (R)
Pure Sine Wave Inverters
12V / 24V DC >> 230V AC
& 110V AC
adjustable between
Centre tapped earth
and Neutral earth bonding
Please read these instructions before installation or use!
Model
Centre tapped Earth
12V 300 watt Twin sockets
12V 600 watt Twin sockets
12V 1000 watt Twin sockets
12V 1600 watt Twin sockets
12V 2000 watt Twin sockets
24V 300 watt Twin sockets
24V 600 watt Twin sockets
24V 1000 watt Twin sockets
24V 1600 watt Twin sockets
24V 2000 watt Twin sockets
12V 1000 watt with RCD
12V 1600 watt with RCD
12V 2000 watt with RCD
RCD option
with 1 meter
24V 1000 watt with RCD
24V 1600 watt with RCD
24V 2000 watt with RCD
Remote control ( fits all the above models )
RoHS
RoHS
compliant
compliant
Option 1
Twin socket
Sterling Power Products
Neutral earth bonded
interchangeable between both
interchangeable between both
interchangeable between both
interchangeable between both
interchangeable between both
interchangeable between both
interchangeable between both
interchangeable between both
interchangeable between both
interchangeable between both
interchangeable between both
Pre-fitted
interchangeable between both
and wired
interchangeable between both
interchangeable between both
AC cable
interchangeable between both
interchangeable between both
Sterling Power Products Ltd.
www.sterling-power.com
www.sterling-power-usa.com
English
French
Deutsch
Pure
sine wave
output
Optional
remote control
with 10 meter
cable
Option 2
Pre wired RCD
adjustable between
Centre tapped earth
and Neutral earth bonding
Remote
Weight
Optional extra
1.4 kg
Optional extra
2.2 kg
Optional extra
3.5 kg
Optional extra
3.6 kg
Optional extra
4.1 kg
Optional extra
1.4 kg
Optional extra
2.2 kg
Optional extra
3.5 kg
Optional extra
3.6 kg
Optional extra
4.1 kg
Optional extra
3.5 kg
Optional extra
3.6 kg
Optional extra
4.1 kg
Optional extra
3.5 kg
Optional extra
3.6 kg
Optional extra
4.1 kg
EN60950-1
EN55022: A2:2003 CLASS B
EN55024:2003
EN61000-3-2:2000
EN61000-3-3:1995/A1:2001
IEC61000-4-2:A2:2003
IEC61000-4-3:20002/A1:2002
IEC61000-4-4:2004
IEC61000-4-6:A1:2004
IEC61000-4-8:A1:2000
Size mm
Cables
190x85x210L
1m DC 8 mm ring
190x85x250L
1m DC 8 mm ring
190x85x300L
8 mm connection
190x85x300L
8 mm connection
190x85x300L
8 mm connection
190x85x210L
1m DC 8 mm ring
190x85x250L
1m DC 8 mm ring
190x85x300L
8 mm connection
190x85x300L
8 mm connection
190x85x300L
8 mm connection
190x85x330L
8 mm connection
190x85x330L
8 mm connection
190x85x330L
8 mm connection
190x85x330L
8 mm connection
190x85x330L
8 mm connection
190x85x330L
8 mm connection
90 x 60 x 20
10 meter
4
technology
ProDigital
Part number
SIB12300
SIB12600
SIB121000
SIB121600
SIB122000
SIB24300
SIB24600
SIB241000
SIB241600
SIB242000
SIBR121000
SIBR121600
SIBR122000
SIBR241000
SIBR241600
SIBR242000
SWR

Advertisement

loading
Need help?

Need help?

Do you have a question about the SIB12600 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sterling Power Products SIB12600

  • Page 1 Optional extra 4.1 kg 190x85x330L 8 mm connection SIBR242000 Remote control ( fits all the above models ) 90 x 60 x 20 10 meter Sterling Power Products Ltd. RoHS RoHS technology www.sterling-power.com compliant compliant ProDigital www.sterling-power-usa.com...
  • Page 2: Specification

    Option 1 Option 2 Standard inverter with dual sockets. Pre-fitted RCD Model. Earth adjustable between centre tapped A 30 mA RCD pre-installed in unit earth ( default ) and Neutral earth bonded pre-wired for neutral earth bonding (simply add rear fuse for neutral earth bonding) to operate RCD.
  • Page 3 RCD be used on all inverters but we recognise that a lot of people do not use RCDs* especially with smaller units, so,alough ilegal to do so, we can only give the best advice to our customer base who adopt poor practices. It is Sterling Power Products actual advice that all inverters should be used in conjunction with a RCD for ultimate safety and to comply with electrical installation codes.
  • Page 4 and electric grinders etc. This could require a 500-1000% power increase terminal and the black cable to the negative terminal of the battery. above the product rating i.e. a 80W fridge may require 800W to fire it up (a Reverse polarity could destroy the unit and would not be under warranty. fridge is probably the hardest product to operate).
  • Page 5 12V 2000 watt avec DDR interchangeable entre les deux Option 4.1 kg 190x85x400L 8 mm connection SWR242000 Contrôle à distance (adaptabe à tous les modèles) 90 x 60 x 20 10 mètres Sterling Power Products Ltd. RoHS RoHS technology www.sterling-power.com compliant compliant ProDigital www.sterling-power-usa.com...
  • Page 6: Specifications

    Option 1 Option 2 Pré câblé avec disjoncteur différentiel Standard, convertisseur avec deux prises. Un DDR 30mamp est pré-installé dans l’appareil Réglable entre: deux phases actives et la terre, pré-câblé, une phase active et neutre une phase active et la terre. pour que le DDR fonctionne.
  • Page 7 Mises à la terre pour l’option 1 DDR = Disjoncteur différentiel Résiduel/détecteur fuite à la terre. Les convertisseurs se présentent sous 2 versions différentes. Deux phases actives ( fig 3 ) Dans ce cas, il n’y a pas un fil de phase et un fil neutre, mais deux fils de phase. Chacun de ces fils est à une tension de 110 volts par rapport au fil de terre, la tension entre les deux fiches est alors de 220 volts, les deux fiches sont actives.
  • Page 8 9) Vous devez utiliser uniquement des appareils électriques dont la 4) Installez des fusibles sur les câbles de courant continu pour chaque puissance est adaptée à votre convertisseur. Il faut aussi tenir compte de installation en respectant les spécifications. la puissance suppémentaire nécessaire au démarrage d’un moteur 5) Installez des fusibles et un interrupteur isolant conformément à...
  • Page 9 24V 2000 W mit 30mA FI Schutzschalter wechselbar optional 4.1 kg 190x85x330L 8mm Anschlussbolzen SIBR242000 Remote control ( fits all the above models ) 90 x 60 x 20 10 meter Sterling Power Products Ltd. RoHS RoHS technology www.sterling-power.com compliant compliant ProDigital www.sterling-power-usa.com...
  • Page 10: Spezifikation

    Option 1 Option 2 Standard Wechselrichter mit 2 Steckdosen Installierter 30mA FI-Schutzschalter Schutzleiter kann wie folgt geschaltet werden: inkl. 1m Kabel neutral = Schutzleiter oder Mittelabgriff (geliefert) (einfach eine Sicherung einstecken (11)) Vorderansicht Vorderansicht Rückansicht Rückansicht Fig 1 Fig 2 1) UK Steckdose 9) positives Kabel / Anschluss 2) Deutsche Steckdose...
  • Page 11 Erdungs-/Schutzleiteroptionen *RCD = Residual earth detector / Breaker / earth leak detector. Wechselrichter werden meistens in 2 verschiedenen Versionen ausgeliefert Mittelabgriff ( fig 3 ) wo es effektiv keine Phase und Neutral gibt, sondern 2 Phasen, welche gegenläufig arbeiten. Man kann jeweils 110V vom Schutzleiter aus gegen jede Phase messen.
  • Page 12 Bitte lesen Sie die beiliegende Anleitung / Information sorgfältig durch. ein Nachweis nicht erbracht, gilt die Garantiezeit ab dem Herstellungsdatum. Sterling Power Products Ltd. garantiert nur Produkte, welche direkt bei - Unsere Garantie deckt Herstellung- und Materialfehler ab. Schäden, Sterling Power Products Ltd. gekauft wurden. Ansonsten wenden Sie die durch Missbrauch, Vernachlässigung, Unfall, Änderungen und...