5.4 WEB serial configuration.................... 19 5.5 Submitting Alteration ....................20 6 Function Description ......................21 6.1 Serial to Ethernet ....................... 21 6.2 Serial to WIFI CLIENT ....................21 6.3 Serial to WIFI AP ....................... 22 6.4 Default mode ......................22 ホームページ:http://www.nissin-tech.com メール:info@nission-tech.com...
Page 4
8 Setting for Peer-to-peer (P2P)..................30 8.1 Get UUID ........................30 8.2 Send/Receive data....................... 30 8.2.1 P2P to open the website of the serial server ............30 8.2.2 Transfer data by P2P .................... 31 ※ 使用されたソースコードはhttp://www.nissin-tech.com/ からダウンロードできます。 ※ この文書の情報は、事前の通知なく変更されることがあり ます。 ※ (株)日新テクニカの書面による許可のない複製は、いかな...
Through the serial server, the traditional serial devices do not need to change any configuration; data can be transmitted through the Internet network. Provide a quick solution for the user’s serial devices to transfer data via Ethernet. ホームページ:http://www.nissin-tech.com メール:info@nission-tech.com...
500000bps rate TCP connection Max connection number > 20 UDP connection Max connection number > 20 Serial baud rate 1200~500000bps Other Parameters Status indicator Status indicator Operating temperature:-20~70℃ Environmental standard Operating humidity:10%~90%RH(non condensing) Storage temperature:-40~80℃ Storage humidity:5%~90%RH(non condensing) ホームページ:http://www.nissin-tech.com メール:info@nission-tech.com...
The outline of the serial WIFI server as follows. Mechanical Dimensions: 85×85×25 mm, not including the antenna. 2.3 External Interface The serial WiFi sever is a serial-WiFi-Ethernet device, its external interface including RS232, DC IN, LAN, WAN, LED, RST. This section will detail the definition of each interface. ホームページ:http://www.nissin-tech.com メール:info@nission-tech.com...
None None None 2.3.2 LAN Interface and WAN interface The serial WiFi server provides two network interface, WAN port and LAN port, the interface is a standard form of RJ-45 interface. RJ-45 interface definition is shown as below: ホームページ:http://www.nissin-tech.com メール:info@nission-tech.com...
Receive Data- 2.3.3 RST Button RST button is used to reset HLK-WR02 Server to the factory settings. METHODS: When the device have startup complete, then using sharp object to press the RST button for at least 10 seconds, all parameters of the server can be set to the default value.
(such as a hub or switch) together, are distributed in each node satellite. This kind of network structure is more convenient in the equipment increase or decrease. The following figure describes the Star like Networking structure: ホームページ:http://www.nissin-tech.com メール:info@nission-tech.com...
However, all the devices in the network share the bandwidth of the bus, therefore, the network transmission rate will decline along with the increase in user. RS - 485 bus structure is typical sample of this structure. The bus structure diagram is as follows: ホームページ:http://www.nissin-tech.com メール:info@nission-tech.com...
For user’s equipment, there does not exist master-slave relationship or a managed device. All user terminals can be equivalent to send and receive data. The structure diagram is as follows: ホームページ:http://www.nissin-tech.com メール:info@nission-tech.com...
2. Connected the serial server with WIFI or network cable (or you can connect the PC and the serial server in the same LAN through hub or router). 3. The IP address of the PC should be set to 192.168.16.X. The default IP address of the Serial ホームページ:http://www.nissin-tech.com メール:info@nission-tech.com...
4.3 Function Test Power on the device, Connect the RS232 and the internet, make sure you PC can ping 192.168.16.254: Serial&TCP_UDP Tool.exe Start the serial Debug software,we use in this sample; Start a TCP client like the below: ホームページ:http://www.nissin-tech.com メール:info@nission-tech.com...
5.2 Serial server Parameter inquiry After passing the IE browser to log in to the serial server, you can see the screen shown below. This page shows the main current operating parameters of serial server. ホームページ:http://www.nissin-tech.com メール:info@nission-tech.com...
Serial function configuration areas Configuration submit area 5.3 WEB network configuration Net mode selection: Default – default work mode ETH-SERIAL – Serial to Ethernet WIFI (CLIENT)-SERIAL – serial to WIFI CLIENT WIFI (AP)-SERIAL) – Serial to WIFI AP ホームページ:http://www.nissin-tech.com メール:info@nission-tech.com...
株式会社日新テクニカ Choose different work mode, the web will show you different page. Mode configuration page is as follows: 5.3.1 Serial to Ethernet-dynamic IP 5.3.2 Serial to Ethernet-static IP 5.3.3 Serial to WIFI CLIENT-dynamic IP ホームページ:http://www.nissin-tech.com メール:info@nission-tech.com...
株式会社日新テクニカ 5.3.4 Serial to WIFI CLIENT-static IP 5.3.5 Serial to WIFI AP 5.4 WEB serial configuration Serial Web configuration page(Serial2Net.asp)is as follows: ホームページ:http://www.nissin-tech.com メール:info@nission-tech.com...
Network Mode:choose Client、Server or none Remote Server Domain/IP:Remote Server Domain/IP address, For example:192.168.11.245 or www.nissin-tech.com . Locale/Remote Port Number:The specified parameter is not the same under the different network modes. Client specifies the port number on the remote, Server specified local port number.
COM1 and ETH1 network can achieve mutual conversion. Ethernet can be configured as dynamic IP address (DHCP), can also be configured as static IP address (STATIC). 6.2 Serial to WIFI CLIENT Serial WiFi Router WIFI WiFi AP COM1 Serial Client DHCP IP / STATIC IP ホームページ:http://www.nissin-tech.com メール:info@nission-tech.com...
WIFI safety: support all encryption methods at present. In this mode, WIFI device can connect with the module and become the device under WIFI LAN. 6.4 Default mode WIFI WIFI Serial WiFi CLIENT Router (PHONE, COM1 pad) Serial ETH2 ETH1 DHCP ENABLE ホームページ:http://www.nissin-tech.com メール:info@nission-tech.com...
In this mode, the module is listening on the specified port, waiting for TCP Client connection, if connected, all TCP data is sent directly to the serial port end, the data of the serial end sent to TCP Client end. 6.4.2 TCP Client Serial WiFi Router TCP Client TCP Client ホームページ:http://www.nissin-tech.com メール:info@nission-tech.com...
6.4.4 UDP Client Serial WiFi Router UDP Client UDP Server In this mode, the module directly sends the serial data to the specified ip, port. The serial data returned from the server-side will be distributed to serial port. ホームページ:http://www.nissin-tech.com メール:info@nission-tech.com...
TCP Server , the device access to the network via a serial port Server , also as a TCP Client end. 7.1.2 Reference setting (Using Access Control Attendance Machine as an example) Network Settings DHCP enable Static IP address is available also ホームページ:http://www.nissin-tech.com メール:info@nission-tech.com...
Some typical applications, such as sensor networks, entrance guard controller and so on, each sensor terminal or entrance guard controller is collecting data all the time in real time. The data collected did not upload at once, but temporarily stored in the ホームページ:http://www.nissin-tech.com メール:info@nission-tech.com...
. In case the UART software in the original user on the server side can real-time inspection to the existence of the UART equipment. 7.2.2 Reference setting (Take sensor as an example) Networking Setting IP address:192.168.2.X Mask:255.255.255.0 Gateway:192.168.2.1 DNS:192.168.2.1 Operation mode setting Start Automatic operation mode Protocol Type:TCP C/S mode:server Port No.:60000 Time Out:120 ホームページ:http://www.nissin-tech.com メール:info@nission-tech.com...
Typical application scenario is the direct connection between the controller and each control node in the industrial field. This in the network can use several UART server to connect, the parameter configuration of the equipment. 7.3.2 Reference setting Device 1 Network setting IP address:192.168.0.1 Mask:255.255.255.0 Gateway:192.168.0.1 ホームページ:http://www.nissin-tech.com メール:info@nission-tech.com...
Page 29
Operation mode Start automatic operation mode Protocol type:TCP C/S mode:client Server address:192.168.0.1 Port No.:8080 Service 3 Network settings IP address:192.168.0.3 Mask:255.255.255.0 Gateway:192.168.0.1 DNS :192.168.0.1 Operation mode setting Start Automatic operation mode Protocol Type:TCP C/S mode:Client Server Address:192.168.0.1 Port No:8080 ホームページ:http://www.nissin-tech.com メール:info@nission-tech.com...
8.2 Send/Receive data 8.2.1 P2P to open the website of the serial server We suppose the serial server is in USA. And my computer is in Japan. P2PCli.exe First, Open our test tool ( ) on my computer: ホームページ:http://www.nissin-tech.com メール:info@nission-tech.com...
Then, open your browser, type in: user: admin password: admin, you will find this below: 8.2.2 Transfer data by P2P We suppose the serial server is in USA. And my computer is in Japan. The serial port parameter is like this: ホームページ:http://www.nissin-tech.com メール:info@nission-tech.com...
Page 32
Because the serial port is: 8080, so we write the Destin Port 8080. We connect the TX and RX together of the serial server’s DB9.That means, the serial port will send the same data what it received. Second: Open the TCP/UDP test tool. Establish a TCP client like this: ホームページ:http://www.nissin-tech.com メール:info@nission-tech.com...