  • Page 1 80144501-001 AC100 User Manual Rev. A 06/03/2016...
  • Page 2 Copyright 2016, International Technologies and Systems Corporation. All rights reserved. ID TECH 10721 Walker Street Cypress, CA 90630 This document, as well as the hardware and software it describes, is furnished under license and may only be used in accordance with the terms of such license. The content of this paper is furnished for informational use, subject to change without notice, and not to be construed as a commitment by ID TECH.
  • Page 3  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  Consult the dealer or an experienced radio/TV technician for help. Changes or modifications to the ID TECH AC100 not expressly approved by ID TECH could void the user's authority to operate the AC100. IC Compliance Warning...
  • Page 4: Table Of Contents

    Table of Content Introduction ........................5       Product Configurations ....................5   Features..........................5     MECHANICAL DESIGN SPECIFICATION ..............5     4.1 Physical Size & Look......................5   4.2 Body Description ......................7   4.3 Connectors ........................7  ...
  • Page 5: Introduction

    This document outlines the mechanical, electrical, and connectivity features of the ID TECH AC100 controller, a Linux-based application deployment platform and connectivity solution for users of ID TECH payment peripherals. The AC100 is designed to allow deployment of a wide range of secure payment apps while easing EMV L3 certification requirements.
  • Page 6  Top view: Logo (IDTECH) Surface: High Polish Top Housing LED-pipe Color: White Color: Transparent Surface: MT11006 Surface: Polish Page 6 of 18...
  • Page 7: Body Description

    RS232 Ethernet USB port (1 of 3) MicroUSB port SD storage access Power connection 4.2 Body Description Reset button  Housing Material: Polycarbonate/ABS resin. Wall thickness: 2.5mm.  Label Material: Lbl;Z-Ultimate;3000 White; 38mmx21mm;5570-R. Contents:  Model Number: IDCL-51  Serial Number: To comply WI 7.5.1-8. ...
  • Page 8: Electronics

     USB-A (3 ports) Connector type: USA2-04F1-XNRX-11 Dimensions: 14.30mm(L)*6.90mm(W)*14.00mm(T)  Micro USB Connector type: 5P F SMT Shell DIP 2.0MM;RoHS (CON188R) Dimensions: 8.0mm(L)*5.55mm(W)*3.0mm(T)  RJ45 (Ethernet) Connector type: KRJ-14006-108XX-GY-A Dimensions: 15.9mm(L)*13.6mm(W)*21.3mm(T)  SD Card Connector type: 96-90025-085 T-FLASH CARD1 Dimensions: 14.75mm(L)*14.5mm(W)*2.00mm(T) ...
  • Page 9 Three Single-Color LEDs (green, yellow, red) under firmware control.  Supports Wi-Fi  Supports micro SD Card  Interfaces The controller has one RS232 and 4 USB ports  One USB port to be a USB Micro B connector (Device) ...
  • Page 10: Environmental

    4.5 Environmental  Electro-Static Discharges (ESD) The electronics are designed to survive ESD of 8kV contact, and 8 kV air discharge, without permanent damage  Environmental Temperature range: o Operating 0 C to 40 C o Storage -40º C to 80º C o Relative humidity: 10% to 95% non-condensing 4.6 Agency Approvals FCC ID...
  • Page 11: Core/Base Application

     CSF key: This key is a subordinate key of the SRK key, and is used to verify the CSF data. CSF (Command Sequence File) is a binary data structure interpreted by the HAB to guide authentication operations.  IMG key: This key is a subordinate key of the SRK key, and is used to verify the u-boot image.
  • Page 12 Get version of this application Command: 02 09 00 00 00 01 34 bf 03 Response: Error status [NULL-terminated version string] Add/Update application Command: 02 length 02 sequence (little endian, 4 bytes) path mode data CRC 03 <length>: The length must be less than 1200 bytes. <sequence>: The range is 0x000000 -0x00100000.
  • Page 13: Test Application

    Add directory Command: 02 length 07 path mode CRC 03 <length>: The length must be less than 200 bytes. <path>: A NULL-terminated string which defines the absolutely path of the directory. The length of the path must be less than 200 bytes. <mode>: Defines the mode of the directory.
  • Page 14 Get Version Get the test application’s version. Command: 01 Response: NULL-terminated string. Set Serial Number Set device's serial number. Command: 02 <Serial Number> <Serial Number>: NULL-terminated S/N Response: 06 if succeeded, or E1 if failed. Get Serial Number Get device's serial number. Command: 03 Response: Device's serial number if succeeded, or E1 if failed.
  • Page 15 Command: 95 Response: The file’s content if succeeded, or E1 if failed. Note: This command will take about 2 seconds. Wi-Fi test Test if the gateway is accessibility through Wi-Fi. Command: 96 <Gateway’s address> <AP name> <AP password> <Gateway’s address>: 4 bytes IP4 address. <AP name>: NULL-terminated AP’s name.
  • Page 16 Command: 9B <MAC Address> <MAC Address>: the length is 17 bytes. The format is xx:xx:xx:xx:xx:xx. eg. 31 31 3A 32 32 3A 33 33 3A 34 34 3A 35 35 3A 36 36 means 11:22:33:44:55:66. Response: 06 if the MAC address is valid, or E1 otherwise Get MAC This command will get the ethernet’s MAC address.
  • Page 17 Revision History Revision Description and Reason for Change Date First draft. 01/05/16 Edits for style and content. Formatting. Deletion of inapplicable 6/3/2016 content. (KT) Page 17 of 18...
  • Page 18: Caution

    Caution   CE1177 1. Adapter shall be installed near the equipment and shall be easily accessible. 2. Avoid exposing your mobile phone to extreme hot or cold temperatures. The temperature range for using the phone is 0°C~40°C. 3. This equipment is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.

Table of Contents