If the inner temperature rises above 65° C, the overheating protection will be activated. The fuse will
burst and the fuse symbol is flashing. Take the following actions:
1. Disconnect the device from the power supply and let it cool down (45 min. minimum).
2. Replace the fuse (see "Fuse replacement").
NOTICE! If an overheating of the device occurs more often, the device might be defective. In
this case, it is neccessary to contact the customer service.

16 Child safety lock

1. Tap LOCK key for approx. 3 seconds to activate the child safety lock. The Lock symbol appears
on the display. The device cannot be operated.
2. Tap LOCK key again for approx. 3 seconds to disable child safety lock. The Lock symbol will dis-
appear from the display. The device can be operated.

17 Fuse replacement

1. Disconnect the device from the power supply and let it cool down (45 min. minimum).
2. Open the fuse compartment with a suitable slot screwdriver counterclockwise.
3. Pull the fuse holder out of the shaft.
4. Remove the defective fuse.
5. Insert the new fuse into the holder.
NOTICE! Use clean cotton gloves or a clean cloth when replacing the fuse.
6. Push the fuse holder back into the shaft.
7. Close the fuse compartment with a slot screwdriver clockwise.

18 Technical data

Model
Flash power
Guide number
Flash charging time
Power range
Modeling lamp
Flash tube
Colour temperature
photo cell operation
range
Flash duration
Overheating protection
Fan
Operating voltage
Fuse
Operating conditions
Storage conditions
Table 1: CM Series
NOTICE! The technical specifications for the flash tube refer to tests with a Hyman flash tube,
produced in Germany. If using other flash tubes, the real values of this information may differ.
The information on charging times refer to tests with a voltage of 220V. If using other voltage
values, the charging times may differ.
Manual_CM-Flashes_en_BRESSER_v012017a
CM-300
CM-400
CM-500
300Ws
400Ws
56
64
1-2 sec.
1-2 sec.
1-2 sec.
adjustable in 6 steps from 1/32 to 1/1; 1/10 energy variable
pluggable version; replaceable by user
AC 180V - 250V at 50Hz; AC 100V - 120V at 60Hz
T8/250V microfuse (5x20mm), 6.3A
dry and dust-free, 0° C to +40° C
CM-600
CM-800 CM-1000 CM-1200
500Ws
600Ws
800Ws
73
80
1-2 sec.
1-2 sec.
Halogen, 150W
5,200K to 5,600K
up to approx. 10m
1/850 sec. to 1/1500 sec.
Yes
Yes
dry, 0° C to +40° C
Features | 16
1000Ws
1200Ws
88
98
108
2-3 sec.
2-3 sec.
7 / 8