SPECIFICATIONS

TYPE
INDOOR UNIT
OUTDOOR UNIT
COOLING CAPACITY

ELECTRICAL DATA

POWER SOURCE
FREQUENCY
RUNNING CURRENT
INPUT WATTS
E.E.R.
MOISTURE REMOVAL
AIR CIRCULATION-Hi
COMPRESSOR
TYPE
DISCRIMINATION
REFRIGERANT

FAN MOTOR

POWER SOURCE
INDOOR UNIT
OUTDOOR UNIT
DIMENSIONS
INDOOR UNIT
OUTDOOR UNIT
WEIGHT
INDOOR UNIT
OUTDOOR UNIT
REFRIGERANT CHARGE (R410A)
FULL CHARGE
AMOUNT
ADDITIONAL REFRIGERANT
2006.03.23
(kW)
(V)
(Hz)
(A)
(kW)
(kW/kW)
( /hr)
(m /hr)
R410A
(g)
(V)
DISCRIMINATION
HI-SPEED
(r.p.m.)
MED-SPEED (r.p.m.)
LO-SPEED
(r.p.m.)
DISCRIMINATION
HI- SPEED
(r.p.m.)
H x W x D
(mm)
H x W x D
(mm)
GROSS / NET
(kg)
GROSS / NET
(kg)
7.5 m (25 ft)
PIPE LENGTH
10 m (33 ft)
15 m (49 ft)
Cool
ARY12FUAD
ARY14FUAD
AOY12FSAJ
AOY14FSDJ
3.50
230
50
5.50
1.24
2.823
1.2
500
Hermetic type, Deposit electrode condenser,
2 poles, Single phase, Induction motor, Rotary
80235435(B)
80236035(B)
800
230
MFA-18NTT
680
640
570
MFB-14VTT
740
217 x 953 x 595
530 x 750 x 250
29 / 25
36 / 34
800 g (28.2oz)
900 g (31.7oz)
837.5 g (29.5oz)
937.5 g (33.1oz)
912.5 g (32.2oz)
1,012.5 g (35.7oz)
15 g/m (0.53oz / 3.3ft)
1
4.20
6.3
1.39
3.02
1.5
640
900
830
730
620
37 / 35