6 WAY 1U Hi RACK MOUNT ZONER

OWNERS MANUAL

For EUROPEAN220V -230V
OPERATION
Hz INTERNATIONAL LTD COMBE HOUSE - STOKE ST MICHAEL -BATH - SOMERSET – ENGLAND

Advertisement

loading
Need help?

Need help?

Do you have a question about the Q-ZONE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for HZ Sound Systems Q-ZONE

  • Page 1: Owners Manual

    6 WAY 1U Hi RACK MOUNT ZONER OWNERS MANUAL For EUROPEAN220V -230V OPERATION Hz INTERNATIONAL LTD COMBE HOUSE - STOKE ST MICHAEL -BATH - SOMERSET – ENGLAND...
  • Page 3: Table Of Contents

    Care is required when installing these units in a rack. It is advisable to put the Rack on its back, then place all the other equipment being fitted to the rack into it before tightening the retaining screws. Contents: OVERVIEW USING THE Q-ZONE SIGNAL INPUT CONTROLS SPECIAL CONNECTIONS ZONE OUTPUTS...
  • Page 4: Overview

    With typical Installation Equipment Speaker Mixer Speaker Active Active Satellite Satellite Microphone Fire Alarm FIRE Area 2 Area 1 Area 4 Area 3 Power Amp Q-Zone CD Or DVD Players Remote Remote Volume Volume Ch 1 Ch 5 Area 6 Area 5...
  • Page 5: Using The Q-Zone

    A. = Unbalanced Male XLR B. = Balanced Male XLR INPUT DIN RCA PHONO Mixer to Mixer Link from Q-Mix The Q-Mix can be to easily linked into a Q-zone via the mixer to mixer link. Left 5 4 Right Screen A Standard screened 5pin Din to 5pin 180º...
  • Page 6: Signal Input Controls

    The Signal Input Controls The Input Link Level This knob sets how much of the source signal is sent into the zoner. Too high and the signal will distort as it overloads the channel. Too low, and the level of background hiss will be more noticeable and you may not be able to get enough signal level to the output of the mixer. The RED peak level LED, is set show at 0dB (0.775v) and is designed to indicate the onset of clipping (distortion), however occasional flashing of this will be observed from very dynamic sources, without causing any undesirable effects.
  • Page 7: Special Connections

    Fire Cut Out This Feature when connected to a fire alarm system will stop sound in all zones, but allows the emergency announcements made via the PA mic channel to be heard in all areas, even if not selected at the time. A Red LED shows that the Fire Cut Out relay is activated, pressing the button below will re-set the Fire Cut Out relay if accidentally tripped.
  • Page 8: Zone Outputs

    8 Way Remote Terminal The Volume Levels of each of the six zones can be controlled from a remote location by using the 8 way plug–in screw terminal provided. Each channel is clearly marked at the back and can be easily hooked up with just 2 wires for each zone Connect 1 wire to the required channel and 1wire from point G, to a Qzone remote volume control unit.
  • Page 9: Trouble Shooting

    Power Connection The wires in the IEC/CEE mains lead are coloured: Earth: Green/Yellow Neutral: Blue Live: Brown As these colours may not correspond with the colour markings identifying the terminal in your plug proceed as follows: Green/Yellow wire must be connected to the terminal which is marked with the letter E or coloured Green.
  • Page 10 Although the greatest care has been taken in the manufacture of this mixer, the possibility remains that faults could occur during use or difficulties could be experienced during initial installation. The cause, however, will rarely be found to be internal to the be the mixer. Below is a list of symptoms and possible causes. Some of the suggested causes may appear obvious, but they can be easily overlooked.
  • Page 11 GUARANTEE YOUR EQUIPMENT IS GUARANTEED FOR A PERIOD OF THIRTYSIX MONTHS TAKEN FROM THE DATE OF PURCHASE OF THE PRODUCT AGAINST ANY DEFECTS DUE TO FAULTY MATERIALS OR FAULTY MANUFACTURING. DURING THIS PERIOD, REPAIRS TO THE EQUIPMENT WILL BE CARRIED OUT WITHOUT CHARGE FOR LABOUR OR MATERIALS BY ANY AUTHORISED DEALER OR THE FACTORY SUBJECT TO THE FOLLOWING CONDITIONS.