CONTOUR Button and LED:
Depress this button to make
ene
rgy from "punching holes" in the sound, especially with mixed program. With the CONTOUR button Out, the A 5360
detector is frequency-independent. The CONTOUR LED turns On when the CONTOUR button is depressed.
C
OMPRESSOR Section
GAIN REDUCTION Meter:
This meter displays how
C
ompressor THRESHOLD LEDs:
These three LEDs indicate the re
On
when the signal is below threshold and the red LED is On when the signal is above threshold. When the A 5360 is
switched to Softcomp mode, the yellow LED is On when the signal is in the softcomp region.
Note: Even though no input signal is being applied, it is normal for the LEDs to flicker when the power is applied or removed.
Com
pressor THRESHOLD Control:
Adjust this knob to set the threshold of compressio
Co
mpressor THRESHOLD control to +20dB will prevent all but the highest level peaks from being compressed. (Se
the Compressor RATIO to 1:1 will turn the Compressor off, regardless of the setting of the Compressor THRESHOLD
control.)
In Har
d Knee mode (Softcomp button out), the THRESHOLD sets a reference level above which input signals will be
pro
cessed by the A 5360's gain change circuitry in the manner defined by the setting of the RATIO control. Input signals
which fall below this level will pass through the A 5360 unprocessed (except for fixed gain changes directed by the
OUTPUT GAIN control).
In Softcomp mode (Sof
as
they approach the THRESHOLD reference level and they do not get fully processed in the manner defined by the
RATIO control until they have passed somewhat above the THRESHOLD reference level. In Softcomp mode there is no
distinct point at which processing begins, and the THRESHOLD setting corresponds to a point on the input/output transfe
curve midway between the onset of processing and that point at which the transfer curve corresponds to the setting of the
RATIO control.
Softcomp Butto
n and LED:
Depress this button to sele
the
signal is in the Softcomp region. When this button is in the Out position, the A 5360 operates as a hard knee
compressor/limiter. (Yellow Softcomp LED is active only in Softcomp Mode.)
In Hard Knee mode, the threshold of compression is defined as that point
cha
nges on a 1:1 basis with changes in the input level.
In Softcomp mode, the threshold of compression is de
"ha
lf-way" into compression.
Compressor RATIO Control
Rotate this control clockwise
in o
utput level, regardless of input level increases above threshold.)
Figure 1: Hard Knee Compression Curve
and Threshold LEDs
the A 5360's detection circuitry less sensitive to low frequency energy, preventing this
much the signal is being attenuated by the compressor and the gate.
lationship of the input signal level to the threshold of compression. The green LED is
tcomp button depressed), signals begin to gradually activate the A 5360's gain change circuitry
ct the Softcomp compression characteristic. The yellow THRESHOLD LED turns On when
:
to increase the amount of compression from 1:1 (no compression) up to ∞:1 (no increase
n from -40dBu (7.8mVrms) to +20dBu (7.8Vrms). Setting the
above which the output level no longer
fined as the middle of the Softcomp threshold region, that is,
Figure 2: Softcomp Compression Curve
and Threshold LEDs
's
tting
r
3