  • Page 1 SL1000AC/SL1500AC Sliding Gate Opener User Manual 2017...
  • Page 2: Safety Instruction

    Dear users, Thank you for choosing this product. Please read the manual carefully before assembling and using it. Please do not leave out the manual if you send this product to a third party. 1. Safety Instruction Please ensure that the using power voltage matches with the supply voltage of gate opener (AC110V or AC220V);...
  • Page 3 2. Packing List (standard) Picture Name Quantity Main engine Manual release key Remote control Spring limit switch accessories box / Magnetic limit switch accessories box Spring limit switch block / Magnetic limit switch block Foundation bolt M10 Spring limit switch block mounting screw M6X10 / Magnetic limit switch block mounting screw M6X18...
  • Page 4: Technical Parameters

    Quantity Steel gear rack 1m/pc Nylon gear rack 1m/pc Infrared sensor Wireless keypad Alarm lamp Mounting plate Hexagon head bolt M10×60 3. Technical parameters SL1000AC Model SL1500AC Power supply 220V/50Hz;110V/60Hz 220V/50Hz;110V/60Hz Motor power 400W 550W Gate moving speed 11-13m/min 11-13m/min...
  • Page 5: Installation

    16Kg 4. Installation SL1000AC/SL1500AC sliding gate opener is applicable to gate weight less than 1000kg/1500kg, and length of the sliding gate should be less than 12m. The drive mode adopts the gear and rack transmission. This gate opener must be installed inside the enclosure or yard for protection.
  • Page 6 Please cast a concrete pedestal with the size of 500mm x 300mm and depth of 250mm in advance, Please verify whether the distance so as to firmly install SL1000AC/SL1500AC gate opener. between the gate and gate opener is suitable before casting the pedestal.
  • Page 7 Embedded screws Figure 4 4.3.2 Main engine installation a) Dismantle the plastic housing on the main engine before installation and keep relevant fasteners properly; b) Please prepare the power line for connecting mounting plate and main engine (the number of power supply cable core shall not be less than 3 PCS, the sectional area of cable core shall not be lower than 1.5mm²...
  • Page 8  Weld all the mounting screws to the gate firmly.  Make sure that all racks on the same straight line.  Pull the gate after installed, make sure the entire trip is flexible no stuck. Figure 6 The fit clearance of output gear and rack is shown in Figure 7 below: Figure 7 Warnings ·To ensure safety, install safety stop blocks on both ends of the rails to prevent the gate out of the rail.
  • Page 9 4.3.4 Limit switch adjustment Spring limit switch - The installation site of spring limit switch is shown in Figure 8: Gate Gate Spring Spring limit limit switch switch Spring Spring limit limit switch switch stop stop block block Gear Gear rack rack Output Output gear...
  • Page 10 Magnetic limit switch - The installation site of magnetic limit switch is shown in Figure 10: Gate Gate Magnets Magnets Magnetic Magnetic limit limit switch switch stop stop block block Gear Gear rack rack Output Output gear gear Figure 10 The installation of magnetic limit switch block is shown in Figure 11: Left side mounting Right side mounting...
  • Page 11 4.3.5 Control board wiring 4.3.5.1 Standard control board Lamp Lamp Capacitor Capacitor Motor Motor Earth Earth Power Power D2 D1 D1 C C W U V PE PE N L 10A 250V 250V 24VDC 24VDC 24VDC 24VDC Infrared Infrared sensor sensor CLLM CLLM...
  • Page 12 DIP Switch 1. External button switch. ON - Three button switch; OFF - One button switch (X7 terminal CLS button can be used to circularly control the main engine OPEN/STOP/CLOSE/STOP). 2. Automatic close time. 3. Automatic close time. 2 ON 3 OFF: automatic close time is 15s, 2 OFF 3 ON: automatic close time is 30s, 2 OFF 3 OFF: automatic close time is 45s, 2 ON 3 ON: no automatic close function.
  • Page 13 Adjustment and operation Remote control operation When remote control is three button mode, three buttons on the remote control to control the main engine OPEN/CLOSE/STOP separately. When remote control is single button mode, one same button on the remote control to circularly control the main engine OPEN/STOP/CLOSE/STOP.
  • Page 14 4.3.5.1 Intelligent control board Hall Hall line line Limit Limit switch switch Loop Loop detetcor detetcor Infrared Infrared sensor sensor 12VDC 12VDC Pedestrian Pedestrian switch switch Capacitor Capacitor O/S/C O/S/C switch switch External External button button switch switch MOT1 MOT1 MOT2 MOT2 Lamp...
  • Page 15 J5 (For the convenience of wiring, this terminal is accompanied with failure diagnosis light) 7. Power supply for fittings: +12V ( Electric current ≤100mA) 8. Photocell input (N.C.); short out the device if not used. 9. GND 10. Loop detector (sensor coil) connector (N.O.) In the closing process, once vehicles are detected by the loop detector, the gate will open soon;...
  • Page 16 VR4: For motor output force adjustment to keep safe usage. Clockwise rotation to increase, counter-clockwise rotation to reduce. Note: the default setting is VR1, VR2, VR3, VR4 are the maximum value, and the user can adjust according to the actual requirement. Warning: the motor output force cannot set too large, just to be able to drive the gate.
  • Page 17 Adjustment and operation Remote control operation When remote control is three button mode, three buttons on the remote control to control the main engine OPEN/CLOSE/STOP separately. When remote control is single button mode, one same button on the remote control to circularly control the main engine OPEN/STOP/CLOSE/STOP.
  • Page 18 5.2 Troubleshooting Problems Possible Reasons Solutions 1.Switch on the power supply. 1.The power is off. The gate cannot open or 2.Check the fuse (code FU), 2.Fuse is burned. close normally, and LED change the fuse if burnt. 3.Control board power wiring with does not light.
  • Page 19 Connect external receiver Remote control working Signal is blocked. antenna, 1.5 meters above distance is too short. ground. 1.Motor output force is not enough The gate moves to the (Intelligent type). 1.Adjust the VR4. middle position to stop 2.Sensitivity of obstacle is too 2.Adjust the VR1.