Summary of Contents for Kahn Little boy
Page 1
Incorrect use may cause fire, electric shock and the unit falling may result in injury or leakage. Contact our designated Kahn service centre on 0333 222 4016 specialists. The manufacturer shall not assume responsibility for accidents or injury caused by incorrect use.
Page 2
Installation - LITTLE BOY Please refer to our youtube channel which offers video advice and guidance for installation. Find us on ... search for Kahn Climate Control or use the QR code Indoor Unit Cover connecting pipe with insulation lagging.
Installation Instructions Location of indoor unit Keep the air inlet and outlet free from any obstructions. Keep the height distance between the indoor and outdoor unit within 5m. If mounted on a wall or suspended from the ceiling ensure they are sturdy enough to bear the weight. Keep at least 1m away from any electrical appliances.
Page 4
Interconnecting cale between Fig 2 indoor and outdoor units Outdoor unit Indoor unit Earth Brown Blue Black Cable 2. Cable 3 This cable This cable goes goes to the to the control box outdoor unit Please refer to the wiring diagram located on the reverse of the cover plate of wiring terminals inside the evaporation unit.
Installation of the Outdoor Unit Air outlet Connecting pipe Removable Panel Electrical Wiring Connections Unscrew and remove the Outdoor unit wiring terminal removable panel Fig 3. Interconnecting cale between indoor and outdoor units Outdoor unit Indoor unit Earth Brown Blue Black Cable 3.
Page 6
Pipe connection - indoor unit Connect both pipes using two adjustable spanners, levering one against the other (see fig 1) Take cable and rubber pipes to outdoor unit. (Fig. 1) Connecting Pipe Instructions for bleeding pre-sealed a/c unit Outdoor unit terminal Align the centre of joint in line with that of flare nut and tighten the nut of connecting pipe with wrench.
Page 7
If any leak exists, close off allen key valves and re-tighten the leaking joint Notice: Do not vent refrigerant into the atmosphere: refrigerant ia a fluorinated greenhouse gas, covered by Kyoto protocol, with a Global Warming Potential (GWP) = 1900(R410A)/1600(R407C)/1700(R22) PUMP DOWN PROCEDURE / REFRIGERANT RECOVERY PROCEDURE: OUTDOOR UNIT SPECIAL INSTALLATION SETTING...