Making Connections

The C4 features auto balanced/unbalanced XLR and ¼"
TRS input and output jacks, permitting connection to virtually
any mixing console. Side-chain inputs are also auto balanced/
unbalanced, on ¼" TRS only. Dynamics processors typically
connect using a mixing console's insert points (send/return),
although they can be used in-line, such as when compressing or
limiting an overall mix, for example.
��� �����
������ ����
������ ������
���������� ��
������ ����
������ ������
��� ����� �
������ ����
������ ������
��� ����� �
������ ����
������ ������
�����
Figure 6. Connection to a mixing console.
��� �����
������ ����
������ ������
�����
Figure 7. Using an external equalizer in the side-chain.
Manual-4
���
�� � ����������
�� � �����
�� � ������
����
�� � ����������
�� � �����
�� � ������
�� � ����������
�� � �����
�� � ������
������
������ ����
�����
�� � ����������
�� � �����
�� � ������
��
������� ��
�� � ����������
������ �������
��
����
��
��
��
��
���
���
���
���
���
���
���
���
���
���
��
�����
����
��
����
�����
��
��
����
��
���
�����
���
���
��
���
�� ���
������������
��
��
���������
��
��
�����
������
�����
�����
�� � �����
�� � ������
��

Front Panel Controls

Each channel of the C4 features the following meters and
controls:

Side-chain and Gain Reduction Meters

-12
-6
-3
-1
dBr
This triple-function meter displays the side-chain level,
threshold indication and amount of gain reduction being ap-
plied. It allows you to see at a glance exactly what the compressor
is doing at all times.
Side-chain Level Display
In Compressor mode, the floating meter displays the side-
chain level relative to the Threshold (dBr), making it easy to gauge
how close the signal is to the onset of compression. The dBr
indicators light from left to right as the signal approaches the
threshold. At threshold, the yellow TH indicator is lit. Above
threshold the TH indicator remains lit and gain reduction oc-
curs. Side-chain meter ballistics follow the rms detector time
constant of 30 ms.
In De-ess mode, the side-chain meter displays the relative
difference between the broadband program material and the
bandpass signal defined by the PEQ, as compared to the set
Threshold.
Example: With THRESHOLD set to -15 dB, the TH indica-
tor lights when the sibilant portion of the program material is 15
dB below the broadband program material. If the sibilants are
18 dB below the broadband material, then the –3 dBr indicator
is lit.
Gain Reduction Display
The Gain Reduction meter displays the amount of gain cor-
rection presently applied to the signal, lighting from right to left
as the amount of gain reduction increases. In Compressor mode,
this meter display the amount of gain correction being applied
to the broadband program material. In De-ess mode. this meter
shows the amount of gain correction being applied to the dy-
namic EQ (DEQ) in the main signal chain. This meter does not
reflect any gain reduction occurring due to limiting.
Gain Reduction meter ballistics follow the actual gain cor-
rection value as determined by the THRESHOLD, RATIO,
ATTACK, RELEASE and KNEE controls. Gain reduction may
be indicated when the Threshold indicator is off, as attack and
decay rates may dictate continued gain reduction even when the
rms level is below threshold.
TH
18
12
8
4
2
1
Reduction dB