Red Arrow POL15LEDEMSCF Installation Instructions Manual

Polo 15w led

Advertisement

Quick Links

POLO 15W LED
Emergency Bulkhead with
Microwave Sensor Corridor
Function
p.1
For models: POL15LEDEMSCF
This installation must be carried out by an electrician.
Please read these instructions carefully before installation.
Leave a copy for the user/maintenance engineer for future reference.

Specification

220-240V
15W
66pcs of 2835 LED
1050 Lumen output / 90lm in emergency mode / 118lm
in corridor function mode
30,000 Hours life expectancy
4000K Colour temperature
Three years guarantee
Dimensions: Ø: 326 x D: 108mm

Description of Microwave Sensor

The microwave sensor option offers presence
detection to provide automatic control of lighting
loads. It is installed inside the luminaire so does
not affect external aesthetics or the IP Rating.
Manual adjustments on the sensor allow it to be
individually tailored to suit your application.

Description of Corridor Function

When the sensor detects movement, the light will
operate at 100%.
If the sensor does not detect any movement, it will
dim to around 10% of normal output.
In emergency mode the Corridor Function will not
work.

Safety

This is a mains powered product. It is designed to be
installed by a qualified electrician and in accordance
with the applicable building and electrical
regulations. Before installation or maintenance the
electrical supply to the product must be isolated.
Red Arrow Trading
Elsworth House, Herries Road South, Sheffield, S6 1QS
Installation Instructions
Installation Instructions
Remove the diffuser & trim from the base by rotating anti-
clockwise to unlatch then pull away.
Loosen the three gear tray retaining screws, rotate the gear
tray anti-clockwise to align the screw heads with the large
aperture of the keyhole slots & remove the gear tray
away from the base. There is a retaining strap to assist with
installation.
Prepare the mains supply cable & fixing points on the chosen
mounting surface ensuring it is able to retain the weight of
the luminaire.
Pass the mains supply cable through the hole & grommet
provided in the base, position the base to the mounting
surface & secure using the screws provided.
It is the installer's responsibility to ensure the fixing points
& cable entry point are appropriately sealed to maintain
the IP54 rating. Silicone bathroom sealant or equivalent is
recommended.
Route the mains supply cable to the terminal block on the
gear tray & terminate ensuring correct polarity is observed.
WARNING: THIS LUMINAIRE MUST BE EARTHED.
It is important that supply cables fitted to luminaires with an
electronic ballast do not run adjacent to leads connected to
the ballast output terminals so as not to affect radio
frequency interference suppression.
Secure the supply cable using the clamp provided in the base.
Refit the the gear tray & secure by retightening the screws.
Refit the diffuser & trim by placing over the base & rotating
clockwise until it locks into position.
Reconnect power supply & check for correct operation.
Luminaires fitted with electronic ballasts are exempt from
insulation resistance tests as this may cause damage to the
ballast.
T: 0800 195 0006
E: sales@redarrowtrading.com
F: 0870 043 3946
www.redarrowtrading.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the POL15LEDEMSCF and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Red Arrow POL15LEDEMSCF

  • Page 1 POLO 15W LED Emergency Bulkhead with Microwave Sensor Corridor Function Installation Instructions For models: POL15LEDEMSCF This installation must be carried out by an electrician. Please read these instructions carefully before installation. Leave a copy for the user/maintenance engineer for future reference. Specification Installation Instructions •...
  • Page 2 Emergency Bulkhead with Microwave Sensor Corridor Function Installation Instructions For models: POL15LEDEMSCF Further Instructions for Emergency version • In addition to the above instructions, a secondary “un-switched” live supply should be fed to the luminaire, in line with the “switched” mains supply. This “un-switched” supply MUST be taken from the same phase as the “switched”...
  • Page 3 Emergency Bulkhead with Microwave Sensor Corridor Function Installation Instructions For models: POL15LEDEMSCF • This should be for the full testing duration period for the luminaire (the reference M3 = Maintained for 3 hours & M1 = Maintained for 1 hour).
  • Page 4 POLO 15W LED Emergency Bulkhead with Microwave Sensor Corridor Function Installation Instructions For models: POL15LEDEMSCF Positioning • The luminaire with detector should be sited so that the occupants of the room fall inside the detection patterns shown in the appropriate diagram below.
  • Page 5 POLO 15W LED Emergency Bulkhead with Microwave Sensor Corridor Function Installation Instructions For models: POL15LEDEMSCF The LED setting indicator will flash to indicate the setting selected as follows: No. of Flashes Setting Length 10 seconds 1 minute 2 minutes 5 minutes...
  • Page 6 POLO 15W LED Emergency Bulkhead with Microwave Sensor Corridor Function Installation Instructions For models: POL15LEDEMSCF • Ensure luminaire is not connected in parallel with other luminaires containing MW sensors. MAINTENANCE • Cleaning should be carried out at regular intervals so as not to impair photometric performance or thermal safety of the luminaire.

Table of Contents