  • Page 1 Installation and Operation Manual ODF, ODR, OUF, OLF & OLR Series Oil-Fired Furnaces 517.787.2100 • www.marsdelivers.com • www.heatcontroller.com...
  • Page 2: Table Of Contents

    INSTALLATION INSTRUCTIONS Installation and Operation Manual - ODF, ODR, OUF, OLF & OLR Series ODF, ODR, OUF, OLF, & OLR Oil-Fired Furnaces Save these instructions for future reference WARNING Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual.
  • Page 3: Start-Up Checklist

    Installation and Operation Manual - ODF, ODR, OUF, OLF & OLR Series OIL FURNACE START-UP CHECKLIST (Complete this page and keep for future reference) Customer Name ________________________________________________________________________________ Address ______________________________________________________________________________________ City __________________________________________ State ________________ Zip Code __________________ Furnace Model # ____________________________________________________ Serial # ___________________ Input Rate __________________________________________________________ Nozzle Used _______________ New Construction ___________________________________________________ Replacement ______________ Date of Installation _____________________________...
  • Page 4: Installation

    Installation and Operation Manual - ODF, ODR, OUF, OLF & OLR Series INSTALLATION In utility rooms or similar installations, the door or access opening should be large enough to permit replacement of the furnace, or another appliance such as a water heater, without disturbing any other equipment.
  • Page 5 Installation and Operation Manual - ODF, ODR, OUF, OLF & OLR Series Non-Suspended Horizontal Installation Horizontal Installation To support the furnace from below, set the furnace on non- combustible material suitable to support the weight of the unit. Top View Using a carpenter’s level, check furnace in at least two directions.
  • Page 6 Installation and Operation Manual - ODF, ODR, OUF, OLF & OLR Series Combustible Floor Installation – Counterflow Counterflow Units (Closet Installation) Cold Air Duct Blower Comparment Burner Combustible Floor Base Sub-base Insulation " 1 Slab Flooring (12" minimum) " 1 Joist Warm Air Plenum "...
  • Page 7: Venting

    Installation and Operation Manual - ODF, ODR, OUF, OLF & OLR Series Combustion and Ventilation Air Adequate provisions for combustion air, ventilation of WARNING furnace, and dilution of the gases must be made. When a furnace is installed in an unconfined space in a building, it Combustion air openings in the front of the furnace must can be assumed that infiltration will be sufficient to supply be kept free of obstructions.
  • Page 8 Installation and Operation Manual - ODF, ODR, OUF, OLF & OLR Series 2. The flue pipe should be as short as possible to do the Factory-Built Chimney job. 3. The internal diameter of the flue pipe or vent connector shall equal the outlet diameter of the flue opening of the appliance.
  • Page 9 Installation and Operation Manual - ODF, ODR, OUF, OLF & OLR Series Masonry Chimney Masonry Chimney Front Flue Front Flue Rear Flue * Barometric control may be installed in the horizontal venting system and located within 18” of the flue outlet of Rear Flue the furnace.
  • Page 10 Installation and Operation Manual - ODF, ODR, OUF, OLF & OLR Series 1. Seal any unused openings in the common venting Draft Control Installation system. 2. Visually inspect the venting system for proper size and horizontal pitch and determine there is no blockage or restriction, leakage, corrosion, or other deficiencies which could cause an unsafe condition.
  • Page 11: Filters

    Installation and Operation Manual - ODF, ODR, OUF, OLF & OLR Series Fan and Limit Control Basement Models The limit control and the separate time delay relay that Permanent filters are supplied with these units. To clean controls blower operation are installed and wired at the the filters, shake to remove any excess dirt and/or use a factory.
  • Page 12 Installation and Operation Manual - ODF, ODR, OUF, OLF & OLR Series Burner Start-Up The proper way to adjust an oil burner is with a CO analyzer 1. Open all shutoff valves in the oil supply line to the and a smoke gun. A properly adjusted burner will result in a furnace.
  • Page 13: Sequence Of Operation

    Installation and Operation Manual - ODF, ODR, OUF, OLF & OLR Series MAINTENANCE AND SERVICE Beckett Oil Burner Nozzle Adjustment Burner must be removed from Oil Burner furnace for this procedure. It is recommended that the nozzle and oil filter be checked before each heating season.
  • Page 14 Installation and Operation Manual - ODF, ODR, OUF, OLF & OLR Series Heat exchanger cleanout kit #ABRSH380-3 is available from Complete National Fuel Gas Codes are available from: the manufacturer. American Gas Association Emergency Fuel Pump Replacement 1515 Wilson Boulevard If replacement of the A2EA6520 fuel pump becomes Arlington, VA 22209 necessary, replace it with another Beckett CleanCut fuel...
  • Page 15: Wiring Diagrams

    Installation and Operation Manual - ODF, ODR, OUF, OLF & OLR Series Wiring Diagram Direct Drive Figure 13...
  • Page 16 Installation and Operation Manual - ODF, ODR, OUF, OLF & OLR Series Wiring Diagram Belt Drive - Heating Only Figure 14...
  • Page 17 Installation and Operation Manual - ODF, ODR, OUF, OLF & OLR Series Wiring Diagram for Horizontal Venting with the Tjernlund System Wiring Diagram for Horizontal Venting with the Field Control System Figure 15...
  • Page 18 Installation and Operation Manual - ODF, ODR, OUF, OLF & OLR Series...
  • Page 19 Installation and Operation Manual - ODF, ODR, OUF, OLF & OLR Series...
  • Page 20 1900 Wellworth Ave., Jackson, MI 49203 • Ph. 517-787-2100 • www.comfort-aire.com • www.century-hvac.com www.marsdelivers.com • www.heatcontroller.com 1/2016...