Willis WMI12MH16S Service Manual page 118

Indoor/outdoor units
Hide thumbs Also See for WMI12MH16S:
Table of Contents

Advertisement

Steps
9.Remove
4-way valve
Discharge the refrigerant completely;unsolder the
pipeline connecting the compressor and the
condenser assy,and then remove the 4-way valve.
10.Remove
compressor
Twist off the three foot nuts on compressor and then
remove the compressor.
11.Remove
motor and motor support
Remove the 4 tapping screws fixing the motor;
disconnect the leading wire insert of the motor and
then remove the motor.
Remove the 2 tapping screws fixing the motor support
and then pull the motor support upwards to remove it.
Procedure
motor support
motor
4-way valve
compressor