Advanced Radio Cells Inc. LIMITED WARRANTY. ARCi warrants to Buyer at the time of delivery that the equipment will be free from defects in material and workmanship under normal use and service. ARCi's sole obligation under these warranties is limited to replacing or repairing, at its option, at its factory, any equipment which is returned to ARCi, transportation, duties, and taxes prepaid, within twelve (12) months after delivery.
Page 3
Advanced Radio Cells Inc. Broadband Fixed Wireless Internet Delivery System Physical Planning and Installation Manual Entire Contents Copyright 2001-2002 Advanced Radio Cells Inc. 910 Campisi Way, Suite 1F Campbell, CA 95008 Phone: 408-558-2760 888-863-8225 FAX: 408-371-7584 www.arcells.com March 1, 2002...
ARCi Internet Broadband Fixed Wireless Internet Delivery System Physical Planning and Installation Manual Table of Contents Table of Contents Introduction System Description Antenna and Frequency Planning Hub Installation Detail Subscriber Installation Detail Link Budget Paramaters Reader Feedback March 1, 2002 Page A2...
Introduction ARCi Internet Vyyo Broadband system, deployed in conjunction with the Wireless Access System , provides a complete end-to-end solution for ISPs and other fixed wireless operators seeking to expand their markets by offering wireless delivery of the Internet to their customers at performance levels that normally exceed DSL. ARCi Internet Solution ARCi...
Page 8
require six ARCi Hub Antennas arranged pointing outward spaced every 60 degrees. A system only looking up a narrow canyon from one end might require only one ARCi Hub Antenna. Cables are run from the antenna(s) into the building to the hub equipment room.
ARCi Internet Basic – System Description Single Sector Hub Configuration ARCi * Telemetry support will be available in late 2002 Upconverter Wireless Hub (WMTS) Gateway DC Power 100 Mbps Ethernet Sw (Probably Unix) Supply Router Network Manager PC Hub Site (Windows/NT/2000) Backhaul to ISP CSU/DSU...
Page 11
ARCi Internet Basic – System Description Single Sector Hub Configuration The ARCi Internet hub location consists of one or more ARCi Hub Antennas mounted on the building roof or adjacent tower or monopole structure and its associated equipment located in the interior hub equipment room.
Page 12
ARCi Internet Basic – System Description Multi-Sector Hub Configuration The Multi-Sector configuration consists of two or more ARCi Hub antennas mounted on a common building roof or tower/monopole structure served by a single Wireless Hub (WMTS) located in an adjacent equipment room. As each Hub antenna covers a sector sixty degrees wide, six ARCi Hub antennas are required for complete 360-degree coverage.
Page 13
Hub Interfaces Industry standard interfaces are employed between the various elements of the Hub system. Installation Refer to Figure 2. Note that specific manufacturer and part numbers are given in the Details section of this manual. See also the ARCi and Vyyo specifications sections of this manual. ARCi Hub Antenna Transmit and receive signal interfaces: 75 ohm type F female connectors...
Page 14
Upconverter 75 ohm type F female connectors Input signal frequency 44 MHz; level range +38 dBmV to +45 dBmV. Output signal frequency 477 through 577 MHz; maximum signal level +60 dBmV. 100 Mbps Ethernet Switch The Ethernet switch is the connection point for all TCP/IP data flow on the ARCi Internet side of the gateway (subnet).
Page 15
If the network IP address is registered with its country’s Network Information Center then the gateway may be nothing more than a conventional router. If, on the other hand, the network IP address is one of the RFC1597 private addresses the gateway must be a proxy server of some sort.
Page 16
ARCi Internet Basic – System Description Subscriber Configuration ARCi Subscriber Modem DC Inserter Figure C2 The ARCi Internet subscriber installation consists of the ARCi subscriber integrated antenna and radio system mounted on the exterior of the subscriber facility and the wireless modem located inside the structure.
Page 17
line of sight to the hub location. At the time of installation the antenna is carefully aimed to transmit and receive to/from the hub. Subscriber Installation Details section provides mounting information and grounding recommendations for the integrated antenna. ARCi Specifications section provides dimension, weight and mounting details.
Antenna and Frequency Planning Antenna Patterns Horizontal The ARCi standard hub antenna is moderately directional, transmitting and receiving in a coverage pattern 60 degrees wide . This means that the geographic coverage of the antenna is 30 degrees on each side of a line drawn straight out from the front of the antenna. Geography further to the sides or rear of the antenna receives increasingly less signal.
Page 20
The frequencies displayed in Table D1 were chosen such that the resulting signal as received by the modem corresponds to a standard EIA CATV channel. This is because the modem, when not properly initialized or when it has lost track of the downstream signal, will “step” through the standard EIA channel list looking for a downstream signal.
Page 21
interference if both hub antennas are transmitting on the same frequency, even though the subscriber is receiving nominally the same signal from both hub antennas. The solution for this is to ensure that adjacent hub antennas are never transmitting on the same frequency.
Page 22
Frequency Planning - Upstream Available Channels There are 3 available upstream channels when channel bandwidth of 3.2 MHz is employed . See Table D2. When configuring the system the user must select the upper or lower carrier as well at the modem transmit frequency.
Page 23
Generally each upstream channel will terminate in a separate upstream port of the WMTS. WMTS upstream port cards are available in single and six input configurations. Thus, a typical six sector omnidirectional hub would utilize a single six input WMTS upstream card. See Figure D3, following.
Hub Installation Detail Schematic Diagram – Outdoor Unit F-Male Connector & RG-6 (Installer Responsibility) DC & Telemetry Connectorized Cable (Included with Hub) Receive Note: Rear weather cap must be in place and all screws secured for outdoor installation. Ground Hub to Supporting Structure or Building Steel per NEC or Local Code...
Page 26
Hub Installation Detail Installation Detail – Outdoor Unit (ODU) Cable connections It will be more convenient to connect the ODU cables and close the headend rear weather cap prior to attaching the ODU to its mounting pipe. Refer to the Schematic Diagram – Outdoor Unit on the previous page.
Page 27
Mounting Mount the ARCi ODU on a vertical pipe with at least 44 vertical inches clear of unrelated hardware or other impediments. The ODU mounting brackets will accommodate pipe from 1.5 to 2.25 inches in outside diameter. Up-tilt or down-tilt is accomplished by means of adjusting the nuts on the 5/16 inch threaded bolts captive to the mounting assembly.
Page 28
Ground Lead Figure E3 ODU Bracket Detail Ground the antenna to the metallic mounting structure (tower or monopole) or suitable rooftop ground point per local codes and installation practices. Normally #6 AWG or larger wire is utilized for this purpose. A ¼-20 ground bolt is provided on the bottom flange of the ODU assembly to attach the ground wire .
Page 29
Cable Access Figure E4 Hub Antenna and Cable Installation March 1, 2002 Page E6...
Page 30
Hub Installation Detail Installation Detail – Outdoor Junction Box (OJB) The Multi-Sector configuration consists of two or more ARCi Hub antennas mounted on a common building roof or tower/monopole structure served by a single Wireless Hub (WMTS) located in an adjacent equipment room.
Page 31
The upper barrier strip terminates the shielded/outdoor CAT 5 cable (black jacket) which is the least expensive multi pair cable we could find. One pair is connected between the ground block and the DC+ bus on the fuse block for power supply remote sensing, a second pair is reserved for the future telemetry application and the other two pairs are spares.
Page 32
Components The OJB pictured here is assembled from the following components: Device Vendor & Part Number Source Enclosure Hoffman A-1412CH Electric Supply Trade www.hoffmanonline.com Inner Panel Hoffman A14P12 Fuse Block Blue Sea Systems 5015 West Marine Retail www.bluesea.com Ground Bus Blue Sea Systems 2301 Dual Bus (use in lieu of fuse block or for telemetry paralleling) Blue Sea Systems 2702...
Page 33
Hub Installation Detail Schematic Diagram – Indoor Equipment Ground Bus - Bond to Equipment Rack & Site Common Ground per NEC. (Installer Responsibility) Lightning DC Power Supply Protectors - Output + Output Remote V. Sense 12 dB Tap 12 dB Tap Telemetry To/From Network Manager PC Upconverter...
Page 34
Hub Installation Detail Installation Detail – Indoor Equipment Grounding Proper grounding is critical to the safety, performance and the life of the equipment installed at Schematic Diagram – Indoor Equipment the hub. Refer to the on the preceding page. ARCi recommends that the installer follow the general grounding practices employed in cellular and PCS hub sites.
Page 35
In a single sector installation a small variable voltage linear DC power supply capable of supplying at least 1000 mA is employed. ARCi has successfully tested the following power supply in the single sector configuration: Agilent E3610A The voltage (IR) drop of the power cable is calculated and the output of the DC supply is set appropriately.
Page 36
The upconverter is adjusted to provide the downstream signal at the center frequency appropriate for the ARCi hub transmitter to create the desired RF carrier frequency. See Table D1 in the Antenna and Frequency Planning section of this manual for more information. The output of the upconverter is connected with RG-6 cables through a 12 dB tap, and thence through the lightning protector to the cable to the ARCi hub antenna.
Page 37
System Level Setting Notes General The head end and subscriber transmitters are designed for linear operation at the maximum output power allowed for compliant operation under the FCC part 15 regulations. In both the head end and the subscriber units the input power level to the ARCi radios determines that of the output. There is no gain adjustment available to the user.
Page 38
The most accurate method of setting the actual output power level is to attach an RF power meter capable of measuring up to 6 GHz to the output of the hub transmitter through a 15 inch long RG142B/U SMA-SMA cable and then adjusting the IF level until the power indicated on the meter is +15 dBm.
Page 39
ARCi Hub Power / Telemetry Cable Convention Belden EN3/Internal Headers 3124A Switchcraft EN3 Downlead Twisted 9744 DC Ground* Black Black [ Black DC + 8.5 VDC* [ Red Telemetry + White Yellow [ White Telemetry – Green Green [ Black 4 &...
Subscriber Installation Detail Schematic Diagram Subscriber Unit NOTE: Coaxial cable length Rear View between DC Inserter & Outdoor Unit must be between 50 and 200 feet. Building Entrance F-Male connector with waterproofing boot and seal F-Male connector for interior installation 10 - 20 dB pad may be required <...
Page 42
Subscriber Installation Detail Installation Detail – Subscriber Outdoor Unit Mounting Mount the ARCi subscriber outdoor unit (ODU) on a vertical pipe with at least 12 inches clear of any hardware or other impediments. The mounting brackets will accommodate pipe diameter from 1.25 to 2 inches.
Page 43
Cable Connection and Grounding Attach the single RG-6 coaxial cable to the F connector on the rear of the subscriber ODU. Waterproof the connection using a suitable method such as taping with Scotch #88. Be sure to leave sufficient slack to allow the antenna to be oriented and that the cable runs directly downward from the connector to avoid water running down the cable and into the F connection.
Page 44
DC Power Supply and Inserter Inside the building, route the RG-6 from the building entrance point to the modem location. Attach an F connector and connect it to the “TO AMPLIFIER” or “TO ANTENNA” F female connector on the power inserter. Depending on the version, the wall mounted DC power supply may: - be permanently connected to the inserter as shown in Figure F4, left, or...
Page 45
Note for Close-in Installations The Subscriber Installation Schematic Diagram (Page F2) shows a 10 or 20 dB pad (attenuator) installed between the power inserter and the modem. Small pads of many values are available with F connectors to screw in line with the coaxial cable connection, and they may be cascaded to sum their attenuation.
Page 47
ARCi Link Budget Parameters Upstream minimum typical maximum Vyyo WMU output spec (dBmV) IFL coax loss - Belden 9116 (calculate; length limited by downstream) 1.42 dB/100 ft @ 55 MHz ARCi CPE IF input (dBmV) ARCi CPE RF output (dBm) ARCi CPE Tx antenna gain (dBi) Path (calculate)
Page 48
Readers of this Manual are Encouraged To Forward Their Corrections and Comments Rick Melzig Advanced Radio Cells Inc. 910 Campisi Way, #1F Campbell, CA 95008 408-558-2763 (direct) 408-371-6934 (fax) rmelzig@arcells.com Revision: March 1, 2002...